Mark Jacques

Mark Jacques

Auto-generated profile, based on publicly available information

Mark Jacques

Institut Laue–Langevin (ILL), 71 Avenue des Martyrs, 38000, Grenoble, France 38000, France

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2016 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
AJAshley Jordan
Ashley Jordan
MJMark Jacques
Mark Jacques
CMCatherine Merrick
Catherine Merrick
JDJuliette Devos
Juliette Devos
VFV. Trevor Forsyth
V. Trevor Forsyth
AMAnne Martel
Anne Martel
The first implementation and use of an in situ size exclusion chromatography (SEC) system on a small-angle neutron scattering instrument (SANS) is described. The possibility of deploying such a system for biological solution scattering at the Institut Laue–Langevin (ILL) has arisen from the fact that current day SANS instruments at ILL now allow datasets to be acquired using small sample volumes with exposure times that are often shorter than a minute. This capability is of particular importance for the study of unstable biological macromolecules where aggregation or denaturation issues are a major problem. The first use of SEC-SANS on ILL's instrument D22 is described for a variety of proteins including one particularly aggregation-prone system.

13 May 2020 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
Ezzeldin MetwalliEzzeldin Metwalli
Ezzeldin Metwalli
KGKlaus Götz
Klaus Götz
SLSebastian Lages
Sebastian Lages
CBChristian Bär
Christian Bär
TZTobias Zech
Tobias Zech
TUTobias Unruh
Tobias Unruh
Exploiting small-angle X-ray and neutron scattering (SAXS/SANS) on the same sample volume at the same time provides complementary nanoscale structural information in two different contrast situations. Unlike an independent experimental approach, the truly combined SAXS/SANS experimental approach ensures the exactness of the probed samples, particularly forin situstudies. Here, an advanced portable SAXS system that is dimensionally suitable for installation in the D22 zone of ILL is introduced. The SAXS apparatus is based on a Rigaku switchable copper/molybdenum microfocus rotating-anode X-ray generator and a DECTRIS detector with a changeable sample-to-detector distance of up to 1.6 m in a vacuum chamber. A case study is presented to demonstrate the uniqueness of the newly established method. Temporal structural rearrangements of both the organic stabilizing agent and organically capped gold colloidal particles during gold nanoparticle growth are simultaneously probed, enabling the immediate acquisition of correlated structural information. The new nano-analytical method will open the way for real-time investigations of a wide range of innovative nanomaterials and will enable comprehensivein situstudies on biological systems. The potential development of a fully automated SAXS/SANS system with a common control environment and additional sample environments, permitting a continual and efficient operation of the system by ILL users, is also introduced.

12 June 2023 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
AMAnne Martel
Anne Martel
CCCristina Cocho
Cristina Cocho
FCFrancesca Caporaletti
Francesca Caporaletti
MJMark Jacques
Mark Jacques
AAAbdelali El Aazzouzi
Abdelali El Aazzouzi
LPLionel Porcar
Lionel Porcar
Described here is the current status of the upgraded in situ size-exclusion chromatography (SEC) system implemented with the D22 small-angle neutron scattering (SANS) instrument at the Institut Laue–Langevin. Since its initial proof of principle in 2016, this SEC–SANS arrangement has been continuously requested by the user community, leading to the design of an upgraded version. A detailed description of the setup and its control is provided, and a few examples of protein structural investigations are presented, which will highlight the various possibilities and limitations of the setup to optimize experimental success.

4 November 2024 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
AVApostolos Vagias
Apostolos Vagias
TMTheodoros Manouras
Theodoros Manouras
ABAndreas Buchner
Andreas Buchner
PGPhilipp Gutfreund
Philipp Gutfreund
LPLionel Porcar
Lionel Porcar
Peter Muller-BuschbaumPeter Muller-Buschbaum
Peter Muller-Buschbaum