This paper presents the development of an energy model of the ESPOL campus main building, in order to estimate, diagnose, and evaluate the electrical energy consumption and also, to propose energy conservation measures (ECMs). This model used simulation tools, such as OpenStudio and EnergyPlus. The final model provides results as the annual energy performance of the building by end-use, the annual utility bill, and others. These results allowed to model some scenarios of ECMs of the building, mainly, aimed to improve lighting and air-conditioning systems. Finally, the greenhouse gas (GHG) emissions generated by each scenario were calculated and analyzed.
This paper provides a comprehensive overview of some key energy harvesting technologies and their applications in buildings. Energy consumption in buildings has attracted much attention in recent years as it is one of the fastest growing sectors for electrical energy consumption worldwide. Furthermore, the continuing growth of the population produces an increased demand for electrical energy to deliver their daily activities, especially in buildings. Consequently, alternative energy generation and energy saving technologies are required in order to meet the projected increase in the demand in coming years. Many researchers have shown that buildings have great potential for energy harvesting and saving initiatives. Energy harvesting technologies appear as a combination of electronic, mechanical, photoelectric, piezoelectric, and thermoelectric processes that collect energy from the environment. The aforementioned technologies have the potential to reduce the amount of electric cabling in buildings as well as extend the service-life of batteries used in different applications in buildings. Some of these technologies have already been implemented commercially, while others are still in the experimental phase. This study aims to analyze the feasibility of different energy harvesting technologies and their application for commercial, educational, and residential buildings and their environments. A comprehensive overview of the different technologies, a discussion on relevant challenges and several implementations of these devices in buildings and their surroundings will be analyzed.
This paper presents an assessment of the effect of the solar reflectance of roofing assemblies on the thermal behavior of a social interest dwelling model located in six representative cities in Ecuador. The model house complies the Ecuadorian building standard. The solar reflectances of 23 local commercial roofing samples were measured following the E1918A Procedure. The thermal behavior of the dwelling was simulated in EnergyPlus. The models use input data, such as: loads and schedules, provided by previous studies on social dwellings. The hours of thermal discomfort based on ASHRAE Standard 55-2013 adaptive model were obtained for each case by varying the experimental solar reflectance of the roofing sample and meteorological data for each hourly time step calculation. Results indicated that the 1808001-50 sample provided between 3240 to 5524 discomfort hours in all cases, being the most suitable roofing assembly for all studied cities due to its higher solar reflectance.
The present article provides an operational energy comparison of modern concrete and foamed geopolymers as envelope materials for single unit housing in Ecuador. The study is performed by replacing the concrete material used in the walls and roof elements with foamed geopolymer components. Residential building sector requires around 35.6% of the total energy demand in Ecuador. For this reason, efforts on building practices improvement are relevant for the Ecuadorian society. The foamed geopolymers are a mixture of aluminosilicate material obtained from Ecuadorian natural zeolite, group of alkaline activators and the foamed agent that when mixing the raw materials and obtain the geopolymer. To assess the potential use of foamed geopolymers as construction material, the annual energy demand for a social interest dwelling was obtained through simulation with EnergyPlus. Prefabricated Insulated Concrete Forms was established as the construction practice for the building model. Annual energy simulations were performed considering two Ecuadorian representative weathers, to Guayaquil and Quito locations. Material properties of foamed geopolymers ware acquired by own experimental facilities. Thermal conductivity was obtained with the use of the hot plate method, while specific heat by means of differential scanning calorimetry (DSC) analysis. This analysis uses foamed geopolymers obtained from two procedures. Thus, these proposed materials presented low density, low thermal conductivity, and acceptable compressive strength values. Finally, an assessment of natural geopolymers as a concrete replacement is presented, including a thermal characterization, and a sustainable construction evaluation. The findings affirm the key role of material selection in construction practices. Reductions around 4.0% in annual electricity demand was achieved for Guayaquil case, while energy consumption decreases around 1.3% for Quito.