Justin Christopher D'ANtin

Justin Christopher D'ANtin

Auto-generated profile, based on publicly available information

Justin Christopher D'ANtin

Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2020 in Biomaterials Science
Verified
Journal Article
Open access
PDF file
IAIrene Anton-Sales
Irene Anton-Sales
JDJustin Christopher D'ANtin
Justin Christopher D'ANtin
JFJorge Fernández-Engroba
Jorge Fernández-Engroba
VCVictor Charoenrook
Victor Charoenrook
ALAnna Laromaine
Anna Laromaine
RMRalph Michael
Ralph Michael
Bacterial nanocellulose exhibits valuable properties to act as a corneal bandage material in terms of conformability, suturability, durability and ease of manipulation in ophthalmological environments.

21 July 2025 in Advanced Healthcare Materials
Verified
Journal Article
Open access
TMThomas Meslier
Thomas Meslier
JDJustin Christopher D'ANtin
Justin Christopher D'ANtin
GJGemma Julio
Gemma Julio
ARAnna Roig
Anna Roig
Bacterial cellulose (BC), a biopolymer produced by Gram‐negative bacteria such as those from the Komagataeibacter genus, has emerged as a promising material in biomedical applications due to its exceptional purity, biocompatibility, mechanical strength, versatility in sterilization, biodegradability, and sustainable production. This comprehensive review traces the evolution of BC‐based medical products from their initial development in the 1980s to present‐day innovations, highlighting the progression of clinical evidence supporting their use. Early clinical studies primarily focused on BC as a temporary skin substitute for burns and ulcers. Over time, the scope of BC applications expanded to include dural defect repair, tympanic membrane reconstruction, and fetal surgery for spina bifida. The quality of clinical evidence has improved, with recent years seeing an increase in randomized controlled trials and larger patient cohorts. Several BC‐based products are already commercially available, supported by regulatory approvals and a growing body of clinical data. This review seeks to serve as a valuable resource by providing an exhaustive recapitulation of published clinical studies on BC‐based medical devices encompassing 3,857 subjects and offering insights into their efficacy, safety, and regulatory considerations. The review outlines future research directions to validate BC's potential across a wide range of in vivo biomedical applications.

14 March 2017 in Ophthalmic Research
Verified
Journal Article
Open access
RBRafael I. Barraquer
Rafael I. Barraquer
LCLaura Pinilla Cortés
Laura Pinilla Cortés
MAMiriam J. Allende
Miriam J. Allende
GMGustavo A. Montenegro
Gustavo A. Montenegro
BIBozidar Ivankovic
Bozidar Ivankovic
RMRalph Michael
Ralph Michael
Purpose: To evaluate a new nuclear cataract grading system which is intended as a surgical guidance system to predict lens hardness before cataract surgery. Methods: The new BCN 10 grading system consists of frontal and cross-sectional slit-lamp images of human eye lenses, ranging from a completely transparent lens nucleus to a totally black nuclear cataract. Validation was done with 9 observers for 110 cases. Two modalities were applied, and observers were asked to use only whole digits and then half digits for grading. Results: Repeatability with regard to test-retest differences showed a mean limit of agreement of 1.70 for whole digits and 1.32 for half digits. The absolute test-retest difference was close to zero for low as well high degrees of cataracts. Reliability for the entire group of 9 observers yielded an intraclass correlation coefficient which was within the same confidence interval, i.e., 0.991-0.995, for whole digits and half digits. Conclusions: BCN 10 grading repeatability was not affected by the severity of the cataract. It showed very good repeatability. Repeatability was significantly higher when the observers used half digits compared to whole digits. Reliability was found to be very good as well, independently of the use of whole or half digits.

24 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JDJustin Christopher D’antin
Justin Christopher D’antin
RBRafael I. Barraquer
Rafael I. Barraquer
FTFrancisco Tresserra
Francisco Tresserra
RMRalph Michael
Ralph Michael
In order to determine whether posterior capsule opacification after cataract surgery, could be delayed or inhibited through the application of hydrogen peroxide (H2O2) or distilled water (H2Od),we extracted lens capsules from 25 human donor eye globes. Samples were treated for 5 min with either 30 mM H2O2 or H2Od or used as controls, and cultured for one month, during which dark field and tilt illumination photos were taken. These were used to observe and quantify, time until cellular growth and confluence on the posterior capsule. After culture, histological sections were stained for H&E, α-SMA, Ki-67 and vimentin and evaluated. We prevented cellular growth in 50% of H2Od and 58% H2O2 of treated samples. The overall prevention of cell growth compared to cultured controls was significant for both treatments while there was no significant difference between them. In the cases where cellular growth was not prevented, both treatments significantly delay cellular growth. Until day 28 none of the treated samples of either type that had shown growth reached total confluence. All cultured controls reached total confluence before treated samples (median = day 11.5). Also, histologically, there was a clear morphological difference between cultured controls and treated samples.

1 May 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
LCLaura Pinilla Cortés
Laura Pinilla Cortés
HBHarvey John Burd
Harvey John Burd
GMGustavo A. Montenegro
Gustavo A. Montenegro
JDJustin Christopher D'Antin
Justin Christopher D'Antin
MMMarek Mikielewicz
Marek Mikielewicz
RMRalph Michael
Ralph Michael
Purpose.: To explore alternative experimental protocols to investigate the biomechanical behavior of the crystalline lens and zonules using ex vivo stretching. Methods.: Radial stretching tests were conducted on the anterior segment (consisting of lens, zonules, ciliary body, and sclera) of four pairs of presbyopic human donor eyes. A simple mechanical model is used to describe the behavior of the anterior segment when tested in this way. Each pair of samples was initially stretched with the ciliary body intact. One sample was retested after cutting the ciliary body radially, and the other sample was retested after removing the lens. Results.: The external forces needed to stretch the sample with the ciliary body intact were significantly greater than for the tests in which the ciliary body had been cut. The forces measured with the ciliary body intact and lens in situ were comparable to the sum of the forces measured in the tests in which the ciliary body had been cut (lens in situ) and the forces measured in the tests on the intact ciliary body with the lens removed. Conclusions.: When stretching tests are conducted on the anterior segment, significant circumferential tensions develop in the ciliary body. This means that the forces applied to the lens and zonules cannot be related directly to the forces applied by the external loading system. If radial cuts are introduced in the ciliary body prior to testing, however, then this difficulty does not arise.

1 March 2018 in Experimental Eye Research
Verified
Journal Article
Closed access
APAntonio Pellegrino
Antonio Pellegrino
HBHarvey John Burd
Harvey John Burd
LCLaura Pinilla Cortés
Laura Pinilla Cortés
JDJustin Christopher D'ANtin
Justin Christopher D'ANtin
NPNik Petrinic
Nik Petrinic
RMRalph Michael
Ralph Michael