Rafael I. Barraquer

Dr. Rafael I. Barraquer


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2021 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
AGAlba Gómez‐Benlloch
Alba Gómez‐Benlloch
AMAndrea Montesel
Andrea Montesel
LPLuis Pareja‐Aricò
Luis Pareja‐Aricò
DMDavid Mingo‐Botín
David Mingo‐Botín
RMRalph Michael
Ralph Michael
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio

18 April 2011 in Acta Ophthalmologica
Verified
Journal Article
Open access
PDF file
RMRalph Michael
Ralph Michael
OGOsvaldo Guevara
Osvaldo Guevara
MPMaria de la Paz
Maria de la Paz
JTJuan Alvarez de Toledo
Juan Alvarez de Toledo
RBRafael I. Barraquer
Rafael I. Barraquer
: Purpose:  To test the feasibility of calculating neural contrast sensitivity function (neural CSF) from conventionally measured total contrast sensitivity function (total CSF) and measured modulation transfer function (MTF). Neural CSF considers the retina and the brain, whereas total CSF considers the optical eye media, the retina and the brain together.Methods:  We studied three groups comprising nine eyes each: one group with normal ocular optics but retinal alterations (mild diabetic retinopathy), one with altered ocular optics and normal retina (keratoconus), and a normal control group.Results:  Total CSF in the keratoconus and retinopathy groups was significantly lower compared to the control group. Modulation transfer function for keratoconus was lower, and in the retinopathy group was similar to that of the control group. Calculated neural CSF in the diabetes mellitus group was lower than in the control group whereas in the keratoconus group it was similar to that of the control group, with overestimations for some keratoconus cases.Conclusion:  It is possible to calculate a meaningful neural CSF from measured total CSF and MTF data. The neural CSF represents a CSF adjusted for optical aberrations. This would allow comparison of the neural component of visual function in eyes with different optical aberrations.

18 September 2019 in Experimental Eye Research
Verified
Journal Article
Closed access
CKCamila Ribeiro Koch
Camila Ribeiro Koch
JDJustin Christopher D'Antin
Justin Christopher D'Antin
FTFrancisco Tresserra
Francisco Tresserra
RBRafael I. Barraquer
Rafael I. Barraquer
RMRalph Michael
Ralph Michael

24 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JDJustin Christopher D’antin
Justin Christopher D’antin
RBRafael I. Barraquer
Rafael I. Barraquer
FTFrancisco Tresserra
Francisco Tresserra
RMRalph Michael
Ralph Michael
In order to determine whether posterior capsule opacification after cataract surgery, could be delayed or inhibited through the application of hydrogen peroxide (H2O2) or distilled water (H2Od),we extracted lens capsules from 25 human donor eye globes. Samples were treated for 5 min with either 30 mM H2O2 or H2Od or used as controls, and cultured for one month, during which dark field and tilt illumination photos were taken. These were used to observe and quantify, time until cellular growth and confluence on the posterior capsule. After culture, histological sections were stained for H&E, α-SMA, Ki-67 and vimentin and evaluated. We prevented cellular growth in 50% of H2Od and 58% H2O2 of treated samples. The overall prevention of cell growth compared to cultured controls was significant for both treatments while there was no significant difference between them. In the cases where cellular growth was not prevented, both treatments significantly delay cellular growth. Until day 28 none of the treated samples of either type that had shown growth reached total confluence. All cultured controls reached total confluence before treated samples (median = day 11.5). Also, histologically, there was a clear morphological difference between cultured controls and treated samples.

1 January 2025 in Biomaterials Research
Verified
Journal Article
Open access
SGSilvia G. Gómez
Silvia G. Gómez
GBGerard Boix-Lemonche
Gerard Boix-Lemonche
OOOrrit-Prat Orrit-Prat
Orrit-Prat Orrit-Prat
RBRaül Bonet
Raül Bonet
JCJaume Caro
Jaume Caro
Jose Maria ManeroJose Maria Manero
Jose Maria Manero
The Boston keratoprosthesis (BKPro) is a critical device for vision restoration in complex cases of corneal blindness, although its long-term retention is challenged by infection risks. This study aims to enhance the antimicrobial properties of the titanium (Ti) backplate of the BKPro by ion implanting silver and copper ions to achieve effective infection control while maintaining cytocompatibility. Research on antimicrobial modifications for BKPro is limited, and while metallic ions like Ag and Cu show promise for biomaterial improvement, their effects on human corneal keratocytes (HCKs) require further study. Ag and Cu were implanted onto rough Ti surfaces, as mono- and coimplantations. Cytotoxicity was assessed in HCKs, and antimicrobial efficacy was tested against Pseudomonas aeruginosa and Candida albicans . After 21 d, monoimplanted Ag samples released 300.4 ppb of Ag + , coimplanted samples released 427.5 ppb of Ag + and 272.3 ppb of Cu ions, and monoimplanted Cu samples released 567.0 ppb of Cu ions. All ion-implanted surfaces supported HCK proliferation, exhibited no cytotoxicity, and showed strong antimicrobial activity. Ag-implanted surfaces provided antibacterial effects through membrane disruption and reactive oxygen species generation, while Cu-implanted surfaces exhibited antifungal effects via impaired enzymatic functions and reactive oxygen species. Coimplanted AgCu surfaces demonstrated synergistic antimicrobial effects, resulting from the synergy between the bactericidal actions of Ag and the oxidative stress contributions of Cu. Additionally, ion-implanted surfaces enhanced HCK adhesion under co-culture conditions. In conclusion, ion implantation effectively imparts antimicrobial properties to the Ti backplate of BKPro, reducing infection risks while preserving compatibility with corneal cells.

1 May 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TGTimoteo González-Cruces
Timoteo González-Cruces
FSFrancisco Javier Aguilar Salazar
Francisco Javier Aguilar Salazar
JTJordi Marfany Od Tort
Jordi Marfany Od Tort
ÁVÁlvaro Sánchez Ventosa
Álvaro Sánchez Ventosa
AVAlberto Villarrubia
Alberto Villarrubia
ACAntonio Cano-Ortiz
Antonio Cano-Ortiz
Purpose: To develop a prediction model based on machine learning to calculate the postoperative vault and the ideal implantable collamer lens (ICL) size, considering for the first time the implantation orientation in a White population. Setting: Arruzafa Ophthalmological Hospital (Cordoba, Spain) and Barraquer Ophthalmology Center (Barcelona, Spain). Design: Multicenter, randomized, retrospective study. Methods: Anterior segment biometric data from 235 eyes of patients who underwent ICL lens implantation surgery were collected using the anterior segment optical coherence tomography CASIA II to train and validate 5 types of multiple regression models based on advanced machine learning techniques. To perform an external validation, a dataset of 45 observations was used. Results: The Pearson correlation coefficient between observed and predicted values was similar in the 5 models in the external validation, with least absolute shrinkage and selection operator regression being the highest (r = 0.62, P < .001), followed by random forest regression model (r = 0.60, P < .001) and backward stepwise regression (r = 0.58, ρ < 0.001). In addition, the predictions generated by the different models showed closer agreement with the actual vault compared with the Nakamura formulas. Using the new methods, about 70% of the observations had a prediction error below 150 μm. Conclusions: Advanced forms of regressions models based on machine learning allow satisfactory calculation of the ideal lens size, offering greater precision to surgeons customizing surgery according to implant orientation.