Lisandra de Camargo Campos

Lisandra de Camargo Campos

Auto-generated profile, based on publicly available information

Lisandra de Camargo Campos

Department of Veterinary Clinics, Universidade Estadual de Londrina Campus Universitário Londrina Paraná Brazil

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2026 in Semina: Ciências Agrárias
Verified
Journal Article
Open access
PDF file
MFMarina Franco
Marina Franco
LCLisandra de Camargo Campos
Lisandra de Camargo Campos
MAMayara Cardoso dos Anjos
Mayara Cardoso dos Anjos
CAClara Saad Arruda
Clara Saad Arruda
TFTuany de Souza Ferreira
Tuany de Souza Ferreira
JLJULIO AUGUSTO NAYLOR LISBOA
JULIO AUGUSTO NAYLOR LISBOA
The objectives of this study were to establish, by ultrasonography, values of the width of the penile urethral lumen of Dorper × Santa Ines lambs, verify the effects of age and Dorper cross degree, and compare two types of linear probes. Forty healthy, uncastrated lambs (18 ½ Dorper and 22 ¾ Dorper) kept confined for fattening were studied. Ultrasonographic examinations were performed at 60 (beginning of confinement period), 120, and 150 days of age (end of confinement period). The penile urethra was examined at four sites: the proximal urethra (perineal region), sigmoid flexure (caudal aspect of the base of the scrotum), distal to the sigmoid flexure (cranial aspect of the base of the scrotum), and distal urethra (half the distance between the glans and the base of the scrotum). Images were acquired in B-mode with transcutaneous cross sections using two types of linear probes: for external use (13 MHz) and for transrectal use in large animals (10 MHz). The urethral lumen width was measured at each anatomical site. Data were analyzed using two-way repeated measures ANOVA. Genetic factors did not influence the results. The image definition was lower for the probe for rectal use. The urethra was identified as a circular or elliptical structure with an anechoic lumen and slightly hyperechoic wall. Urethral width increased with age in the proximal urethra (P = 0.038), distal to the sigmoid flexure (P = 0.013), and in the distal urethra (P < 0.001), but not in the sigmoid flexure (P = 0.056). The effect of the type of probe used was confirmed at the four anatomical sites examined (P < 0.001), with higher values measured using the probe for rectal use. With the probe for external use, the lumen width ranged 0.5‒2.0 mm in the proximal urethra, 0.6‒1.9 mm in the sigmoid flexure, 0.7‒2.0 mm distal to the sigmoid flexure, and 0.7‒2.1 mm in the distal urethra. With the probe for rectal use, the values were 0.6‒2.3, 0.8‒2.2, 0.7‒2.1, and 0.8‒2.5 mm, respectively. Ultrasound examination of the penile urethra of Dorper × Santa Ines lambs is feasible, and the values obtained for lumen width can be accepted as a parameter for comparison. This examination can be performed using a linear probe for rectal use in large animals.

12 October 2026 in Veterinary Radiology & Ultrasound
Verified
Journal Article
Open access
PDF file
MFMarina Franco
Marina Franco
LCLisandra de Camargo Campos
Lisandra de Camargo Campos
MAMayara Cardoso dos Anjos
Mayara Cardoso dos Anjos
NMNicoly Nayana Marcom
Nicoly Nayana Marcom
EMEmelly Selmer Moura
Emelly Selmer Moura
JLJULIO AUGUSTO NAYLOR LISBOA
JULIO AUGUSTO NAYLOR LISBOA
This study aimed to determine, using ultrasonography, the width of the penile urethral lumen in Texel lambs and to compare two types of linear probes. Thirty healthy, uncastrated lambs kept in confinement for fattening were subjected to ultrasound examinations at 60, 120, and 150 days of age. The penile urethra was examined at four sites: proximal urethra, sigmoid flexure, distal to the sigmoid flexure, and distal urethra. The images were obtained in B‐mode with cross sections using two types of linear probes: for external use (external probe: EP; 13 MHz) and for transrectal use in large animals (rectal probe: RP; 10 MHz). Data were analyzed using a two‐way repeated‐measures ANOVA. The image quality was superior when using EP. The urethra was identified as a circular or elliptical structure with a slightly hyperechoic wall and an anechoic lumen. At the four anatomical sites, the width of the urethra increased with age ( p < 0.001), and the values measured using RP were higher ( p < 0.05). With EP, the lumen width was 1.0‒3.4 mm in the proximal urethra, 0.6‒3.3 mm in the sigmoid flexure, 0.5‒2.9 mm in the region distal to the sigmoid flexure, and 0.7‒2.5 mm in the distal urethra; with RP, these values were 0.8‒3.9, 0.6‒3.3, 0.7‒3.3, and 0.8‒2.9 mm, respectively. Ultrasound examination of the penile urethra is feasible, and the values obtained for the lumen width can be accepted as physiological standards for comparison. This examination can be performed with a linear RP in large animals.