Jiří Kuželka

Jiří Kuželka

Auto-generated profile, based on publicly available information

Jiří Kuželka

Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 166 07 Prague, Czech Republic

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2012 in International Journal of Fatigue
Verified
Journal Article
Closed access
MNM. Nesládek
M. Nesládek
MŠM. Španiel
M. Španiel
JJJ. Jurenka
J. Jurenka
JRJ. Růžička
J. Růžička
JKJ. Kuželka
J. Kuželka

1 March 2018 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
Jan DzuganJan Dzugan
Jan Dzugan
MŠMiroslav Španiel
Miroslav Španiel
APAntonín Prantl
Antonín Prantl
Pavel KonopikPavel Konopik
Pavel Konopik
JRJan Růžička
Jan Růžička
JKJiří Kuželka
Jiří Kuželka

30 June 2014 in Advances in Engineering Software
Verified
Journal Article
Closed access
MŠMiroslav Španiel
Miroslav Španiel
APA. Prantl
A. Prantl
Jan DzuganJan Dzugan
Jan Dzugan
JRJ. Ru˚žička
J. Ru˚žička
MMM. Moravec
M. Moravec
JKJ. Kuželka
J. Kuželka

1 January 2011 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
SKSigmar Kopp
Sigmar Kopp
JKJiri Kuzelka
Jiri Kuzelka
TGTomas Goldmann
Tomas Goldmann
LHLucie Himmlova
Lucie Himmlova
SIStefan K.A. Ihde
Stefan K.A. Ihde
The purpose of this study was to present the amount and distribution of pressure, stress, and deformation energy when basal implants in the mandible are restored with a bridge which is loaded at two different stages of bone healing. The model geometry and material properties of the mandible were gained from CT scans of a human mandible. The material model used in this study defined bone as an inhomogeneous, linear elastic isotropic material. The masseter and temporal muscles were considered as rigid connections between the bones in typical positions and directions. The rotation axis was simulated in the temporomandibular joint. The loading force of 450 N was assumed to be in the middle between the left molar and left canine implant. In freshly operated bone, the total deformation energy is 30% higher than in healed bone, due to the defined energy absorbing soft bone areas. Approximately 90% of the deformation energy is absorbed by the bone, regardless of the healing state of the bone. The immediate rigid implant splinting distributes peak forces. To cope with these energies, the necessity of a reduction of total masticatory forces or the use of additional implants for force distribution should be considered individually.

21 August 2008 in Meccanica
Verified
Journal Article
Closed access
PDF file
MŠMiroslav Španiel
Miroslav Španiel
JJJosef Jurenka
Josef Jurenka
JKJiří Kuželka
Jiří Kuželka

1 December 2008 in Biomedical Papers
Verified
Journal Article
Open access
PDF file
TGTomas Goldmann
Tomas Goldmann
SIStefan K.A. Ihde
Stefan K.A. Ihde
JKJiri Kuzelka
Jiri Kuzelka
LHLucie Himmlova
Lucie Himmlova
AIM: Bendable and angulated single-piece implants are used alternatively to screwable abutments in two-piece dental implant designs. Though used frequently, data on the stress distribution within such implants are not available and the questio...