Mohsen Adabi

Mohsen Adabi

Auto-generated profile, based on publicly available information

Mohsen Adabi

Young Researchers and Elite Club, Roudehen Branch, Islamic Azad University, Roudehen, Iran

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2016 in Artificial Cells, Nanomedicine, and Biotechnology
Verified
Journal Article
Closed access
MAMahdi Adabi
Mahdi Adabi
MNMajid Naghibzadeh
Majid Naghibzadeh
MAMohsen Adabi
Mohsen Adabi
MZMohammad Ali Zarrinfard
Mohammad Ali Zarrinfard
SESeyedeh Sara Esnaashari
Seyedeh Sara Esnaashari
HGHossein Ghanbari
Hossein Ghanbari
There has been huge interest in applications of nanomaterials in biomedical science, including diagnosis, drug delivery, and development of human organs. Number of these nanomaterials has been already studied in human or at pre-clinical trial. There is a growing concern on potential toxicity and adverse effects of nanomaterials on human health, including lack of standard method of assessment of toxicology of these materials. Our investigation indicated that the bare and small nanoparticle have higher toxicity than modified and bulk materials, respectively. In addition, spherical nanoparticles have less toxicity than rod nanoparticles due to immune response of body.

1 December 2016 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
BMBasil Mujokoro
Basil Mujokoro
MAMohsen Adabi
Mohsen Adabi
ESEsmaeil Sadroddiny
Esmaeil Sadroddiny
MAMahdi Adabi
Mahdi Adabi
MKMasood Khosravani
Masood Khosravani

14 February 2015 in e-Polymers
Verified
Journal Article
Open access
MKMohammad Ali Karimi
Mohammad Ali Karimi
PPPouran Pourhakkak
Pouran Pourhakkak
MAMahdi Adabi
Mahdi Adabi
SFSaman Firoozi
Saman Firoozi
MAMohsen Adabi
Mohsen Adabi
MNMajid Naghibzadeh
Majid Naghibzadeh
The purpose of this study was to investigate the validity of an artificial neural network (ANN) method in the prediction of nanofiber diameter to assess the parameters involved in controlling fiber form and thickness. A mixture of polymers including poly(vinyl alcohol) (PVA) and chitosan (CS) at different ratios was chosen as the nanofiber base material. The various samples of nanofibers were fabricated as training and testing datasets for ANN modeling. Different networks of ANN were designed to achieve the purposes of this study. The best network had three hidden layers with 8, 16 and 5 nodes in each layer, respectively. The mean squared error and correlation coefficient between the observed and the predicted diameter of the fibers in the selected model were equal to 0.09008 and 0.93866, respectively, proving the efficacy of the ANN technique in the prediction process. Finally, three-dimensional graphs of the electrospinning parameters involved and nanofiber diameter were plotted to scrutinize the implications.

1 December 2015 in Transactions of Nonferrous Metals Society of China
Verified
Journal Article
Closed access
MAMohsen Adabi
Mohsen Adabi
AAAhmad Ali Amadeh
Ahmad Ali Amadeh

16 October 2019 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
MAMohsen Adabi
Mohsen Adabi
MAMahdi Adabi
Mahdi Adabi
In this study, a novel non-enzymatic glucose sensor was successfully produced using nickel electrodeposition on an oil free carbon nanofiber (CNF) mat prepared by electrospinning method. The as-prepared Ni/CNF mat electrode was studied by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). The characterization results showed that not only was nickel coating electrodeposited on the CNF mat but also the nickel coating was uniformly deposited on the CNF mat electrode. The electrochemical properties of Ni/CNF mat were evaluated using cyclic voltammetry (CV) and amperometry measurements. It was found that the Ni/CNF mat electrode had good electrocatalytic activity toward the oxidation of glucose and demonstrated a wide linear range of 0.002–5 mM, a low detection limit of 0.57 µM, a rapid response time (2 s), a high selectivity with no interference from other oxidable species, good reproducibility and long-term stability. Moreover, the prepared sensor was used to identify glucose in real sample species. Therefore, Ni/CNF mat electrode due to good analytical performance, cost effective and simple preparation method can be proposed as a promising sensor for non-enzymatic glucose detection.

1 September 2015 in Surface Engineering
Verified
Journal Article
Closed access
MAM. Adabi
M. Adabi
AAA. Amadeh
A. Amadeh
Ni–Al composite coatings were prepared on 6061 Al alloy by pulse electrodeposition from a modified Watts bath containing suspended Al particles. The effect of surfactant and Al concentrations as well as electrodeposition parameters on composition, crystallographic texture, microhardness, adhesion strength and wear resistance of the coatings was investigated. The results indicated that addition of surfactant up to 0·25 g L−1 increased the amount of codeposited Al particles in nickel matrix. The incorporation of Al particles changed the preferred crystallographic orientation of the coating from (200) to (111). By increasing the current density and duty cycle, the amount of Al particles embedded in Ni matrix decreased and, therefore, the adhesion strength of the coating was improved whereas its microhardness reduced. Meanwhile, codeposition of Al particles increased the wear rate of composite coating with respect to pure nickel one. In other words Ni–Al coating is not suitable for wear resistant applications.