Jia Shen

Jia Shen

Auto-generated profile, based on publicly available information

Jia Shen

Department of Pediatric Thoracic and Cardiovascular Surgery Shanghai Children's Medical Center Shanghai China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

22 April 2022 in Artificial Organs
Verified
Journal Article
Closed access
YYYinyu Yang
Yinyu Yang
XYXindi Yu
Xindi Yu
ZGZheng Guo
Zheng Guo
WZWei Zhang
Wei Zhang
JSJia Shen
Jia Shen
WWWei Wang
Wei Wang

30 April 2017 in The Korean Journal of Parasitology
Verified
Journal Article
Open access
PDF file
XWXiaoying Wu
Xiaoying Wu
JRJianwei Ren
Jianwei Ren
ZGZulu Gao
Zulu Gao
YXYun Xu
Yun Xu
HXHuiqun Xie
Huiqun Xie
ANAn Ning
An Ning
China still has more than 30,000 patients of advanced schistosomiasis while new cases being reported consistently. D-dimer is a fibrin degradation product. As ascites being the dominating symptom in advanced schistosomiasis, the present study aimed to explore a prediction model of ascites with D-dimer and other clinical easy-achievable indicators. A case-control study nested in a prospective cohort was conducted in schistosomiasis-endemic area of southern China. A total of 291 patients of advanced schistosomiasis were first investigated in 2013 and further followed in 2014. Information on clinical history, physical examination, and abdominal ultrasonography, including the symptom of ascites was repeatedly collected. Result showed 44 patients having ascites. Most of the patients' ascites were confined in the kidney area with median area of 20 mm2. The level of plasma D-dimer and pertinent liver function indicators were measured at the initial investigation in 2013. Compared with those without ascites, cases with ascites had significantly higher levels of D-dimer (0.71±2.44 μg/L vs 0.48±2.12 μg/L, P=0.005), as well ALB (44.5 vs 46.2, g/L) and Type IV collagen (50.04 vs 44.50 μg/L). Receiver operating characteristic curve analyses indicated a moderate predictive value of D-dimer by its own area under curve (AUC) of 0.64 (95% CI: 0.54-0.73) and the cutoff value as 0.81 μg/L. Dichotomized by the cutoff level, D-dimer along with other categorical variables generated a prediction model with AUC of 0.76 (95% CI: 0.68-0.89). Risks of patients with specific characteristics in the prediction model were summarized. Our study suggests that the plasma D-dimer level is a reliable predictor for incident ascites in advanced schistosomiasis japonica patients.

22 October 2022 in arXiv
Verified
Preprint
Open access
PDF file
He LiHe Li
He Li
YLYunbo Li
Yunbo Li
WHWang Sheng Hu
Wang Sheng Hu
SHSheng Jie Huang
Sheng Jie Huang
JSJia Lin Shen
Jia Lin Shen
TCTie Jun Cui
Tie Jun Cui
We propose to achieve joint detections of frequency and direction of arrival in wideband using single sensor based on an active metasurface with programmable transmission states of pass and stop. By integrating two PIN diodes with the opposite directions into the proposed single-layer and ultrathin meta-atom, the transmission performance with 10 dB difference between the pass and stop states is realized in the bandwidth from 5.9 GHz to 8.8 GHz using field-circuit co-simulations. Accordingly, random receiving patterns are generated by controlling the programmable metasurface composed of the switchable meta-atoms. Afterwards, the frequency and direction information of sources located in the far field are detected using the modified algorithm of estimating signal parameters via rotational invariance techniques (ESPRIT) and the compressive sensing method, respectively. A sample of the programmable metasurface is fabricated and the voltage control system is built up correspondingly. To entirely verify the validity of the proposed method, we conduct three kinds of experiments with one single source, double sources with different frequencies, and double sources with the same frequency, respectively. In all cases, the source information of frequency and direction has been detected preciously in measurements in the frequency band from 6.2 GHz to 8.8 GHz.