Robert Marc Lebel

Robert Marc Lebel

Auto-generated profile, based on publicly available information

Robert Marc Lebel

GE Healthcare, New York, NY 10032, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Radiology
Verified
Journal Article
Closed access
MKMinjae Kim
Minjae Kim
HKHo Sung Kim
Ho Sung Kim
HKHyun Jin Kim
Hyun Jin Kim
JPJi Eun Park
Ji Eun Park
SPSeo Young Park
Seo Young Park
MLMarc R. Lebel
Marc R. Lebel
MRI with deep learning–based reconstruction at 1 mm showed higher diagnostic performance than conventional 3-mm slice reconstruction in identifying cavernous sinus invasion by postoperative residua... Background Achieving high-spatial-resolution pituitary MRI is challenging because of the trade-off between image noise and spatial resolution. Deep learning–based MRI reconstruction enables image d...

1 November 2021 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
KKKevin Koch
Kevin Koch
MSMohammad Sherafati
Mohammad Sherafati
VAV. Emre Arpinar
V. Emre Arpinar
SBSampada Bhave
Sampada Bhave
RARobin Ausman
Robin Ausman
RMRajeev Mannem
Rajeev Mannem
A deep learning MRI reconstruction algorithm with two different denoising settings was evaluated, and output images were found to have higher image quality compared with images processed with conve... Purpose To evaluate two settings (noise reduction of 50% or 75%) of a deep learning (DL) reconstruction model relative to each other and to conventional MR image reconstructions on clinical orthope...

1 November 2018 in NeuroImage
Verified
Journal Article
Open access
BGBryce L. Geeraert
Bryce L. Geeraert
RLR. Marc Lebel
R. Marc Lebel
AMAlyssa C. Mah
Alyssa C. Mah
SDSean C. Deoni
Sean C. Deoni
DADavid C. Alsop
David C. Alsop
CLCatherine Lebel
Catherine Lebel
Sensitive and specific biomarkers of myelin can help define baseline brain health and development, identify and monitor disease pathology, and evaluate response to treatment where myelin content is affected. Diffusion measures such as radial diffusivity (RD) are commonly used to assess myelin content, but are not specific to myelin. Inhomogeneous magnetization transfer (ihMT) and multicomponent driven equilibrium single-pulse observation of T1 and T2 (mcDESPOT) offer quantitative parameters (qihMT and myelin volume fraction/VFm, respectively) which are suggested to have improved sensitivity to myelin. We compared RD, qihMT, and VFm in a cohort of 23 healthy children aged 8-13 years to evaluate the similarities and differences across these measures. All 3 measures were significantly related across brain voxels, but VFm and qihMT were significantly more strongly correlated (qihMT-VFm r = 0.89) than either measure was with RD (RD-qihMT r = -0.66, RD-VFm r = -0.74; all p < 0.001). Mean parameters differed in several regions, especially in subcortical gray matter. These differences can likely be explained by unique sensitivities of each measure to non-myelin factors, such as crossing fiber geometry, axonal packing, fiber orientation, glial density, or magnetization transfer effects in a voxel. We also observed an orientation dependence of qihMT in white matter, such that qihMT decreased as fiber orientation went from parallel to perpendicular to B0. All measures appear to be sensitive to myelin content, though qihMT and VFm appear to be more specific to it than RD. Scan time, noise tolerance, and resolution requirements may inform researchers of the appropriate measure to choose for a specific application.

1 January 2019 in NeuroImage: Clinical
Verified
Journal Article
Open access
TWThomas Welton
Thomas Welton
JMJerome J. Maller
Jerome J. Maller
RLR. Marc Lebel
R. Marc Lebel
ETEk Tan
Ek Tan
DRDominic Rowe
Dominic Rowe
SGStuart M Grieve
Stuart M Grieve
To construct a clinical diagnostic biomarker using state-of-the-art microstructural MRI in the motor cortex of people with amyotrophic lateral sclerosis (ALS). Clinical and MRI data were obtained from 21 ALS patients (aged 54 ± 14 years, 33% female) and 63 age- and gender-matched controls (aged 48 ± 18 years, 43% female). MRI was acquired at 3T and included T1-weighted scan (for volumetrics), arterial spin labelling (for cerebral blood flow), susceptibility-weighted angiography (for iron deposition) and multiband diffusion kurtosis imaging (for tissue microstructure). Group differences in imaging measures in the motor cortex were tested by general linear model and relationships to clinical variables by linear regression. The ALS group had mild-to-moderate impairment (disease duration: 1.8 ± 0.8 years; ALS functional rating scale 40.2 ± 6.0; forced vital capacity 83% ± 22%). No age or gender differences were present between groups. We found significant group differences in diffusion kurtosis metrics (apparent, mean, radial and axial kurtosis: p < .01) and iron deposition in the motor cortex (p = .03). Within the ALS group, we found significant relationships between motor cortex volume, apparent diffusion and disease duration (adjusted R2 = 0.27, p = .011); and between the apparent and radial kurtosis metrics and ALS functional rating scale (adjusted R2 = 0.25, p = .033). A composite imaging biomarker comprising kurtosis and iron deposition measures yielded a maximal diagnostic accuracy of 83% (81% sensitivity, 85% specificity) and an area-under-the-curve of 0.86. Diffusion kurtosis is sensitive to early changes present in the motor region in ALS. We propose a composite imaging biomarker reflecting tissue microstructural changes in early ALS that may provide clinically valuable diagnostic information.

6 January 2022 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
MKM. Kim
M. Kim
HKH.S. Kim
H.S. Kim
JPJ.E. Park
J.E. Park
SPS.Y. Park
S.Y. Park
YKYoung-Hoon Kim
Young-Hoon Kim
MLM.R. Lebel
M.R. Lebel
BACKGROUND AND PURPOSE: Accurate radiologic prediction of cavernous sinus invasion by pituitary adenoma remains challenging. We aimed to assess whether 1-mm-slice-thickness MRI with deep learning–based reconstruction can better predict cavernous sinus invasion by pituitary adenoma preoperatively and to estimate the depth of invasion and degree of contact in relation to the carotid artery, compared with 3-mm-slice-thickness MRI. MATERIALS AND METHODS: This single-institution, prospective study included 67 consecutive patients (mean age, 53 [SD, 12] years; 28 women), between January and August 2020, who underwent a combined contrast-enhanced T1-weighted imaging protocol of 1-mm-slice-thickness MRI + deep learning–based reconstruction and 3-mm-slice-thickness MRI. An expert neuroradiologist who was blinded to the imaging protocol determined cavernous sinus invasion using the modified Knosp classification on 1-mm-slice-thickness MRI + deep learning–based reconstruction and 3-mm-slice-thickness MRI, respectively. Reference standards were established by the consensus of radiologic, intraoperative, pathologic, and laboratory findings. The primary end point was the diagnostic performance of each imaging protocol, and the secondary end points included depth of invasion and degree of contact in relation to the carotid artery. RESULTS: The diagnostic performance of 1-mm-slice-thickness MRI + deep learning–based reconstruction (area under the curve, 0.79; 95% CI, 0.69 − 0.89) in predicting cavernous sinus invasion by pituitary adenoma was higher than that of 3-mm-slice-thickness MRI (area under the curve, 0.61; 95% CI, 0.52–0.70; P < .001). One-millimeter-slice-thickness MRI + deep learning–based reconstruction demonstrated greater depth of invasion by pituitary adenomas from the medial intercarotid line than 3-mm-slice-thickness MRI (4.07 versus 3.12 mm, P < .001). A higher proportion of cases were in a greater degree of contact with the intracavernous ICA with 1-mm-slice-thickness MRI + deep learning–based reconstruction than with 3-mm-slice-thickness MRI (total encasement, 37.3% versus 13.4%, P < .001; >270°, 38.8% versus 16.4%, P < .001). CONCLUSIONS: Compared with 3-mm-slice-thickness MRI, 1-mm-slice-thickness MRI + deep learning–based reconstruction showed a higher diagnostic performance in preoperatively predicting cavernous sinus invasion by pituitary adenomas and demonstrated a greater depth and degree of contact in relation to the carotid artery.

5 July 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
Merel Margaretha van der ThielMerel Margaretha van der Thiel
Merel Margaretha van der Thiel
CRC. Rodriguez
C. Rodriguez
PGPanteleimon Giannakopoulos
Panteleimon Giannakopoulos
MBMichael Burke
Michael Burke
RLR. Marc Lebel
R. Marc Lebel
SHSven Haller
Sven Haller
BACKGROUND AND PURPOSE: Multidelay arterial spin-labeling is a promising emerging method in clinical practice. The effect of imaging parameters in multidelay arterial spin-labeling on estimated cerebral blood flow measurements remains unknown. We directly compared 3-delay versus 7-delay sequences, assessing the difference in the estimated transit time and blood flow. MATERIALS AND METHODS: This study included 87 cognitively healthy controls (78.7 ± 3.8 years of age; 49 women). We assessed delay and transit time–uncorrected and transit time–corrected CBF maps. Data analysis included voxelwise permutation-based between-sequence comparisons of 3-delay versus 7-delay, within-sequence comparison of transit time–uncorrected versus transit time–corrected maps, and average CBF calculations in regions that have been shown to differ. RESULTS: The 7-delay sequence estimated a higher CBF value than the 3-delay for the transit time–uncorrected and transit time–corrected maps in regions corresponding to the watershed areas (transit time–uncorrected = 27.62 ± 12.23 versus 24.58 ± 11.70 mL/min/100 g, Cohen9s d = 0.25; transit time–corrected = 33.48 ± 14.92 versus 30.16 ± 14.32 mL/min/100 g, Cohen9s d = 0.23). In the peripheral regions of the brain, the estimated delay was found to be longer for the 3-delay sequence (1.52408 ± 0.25236 seconds versus 1.47755 ± 0.24242 seconds, Cohen9s d = 0.19), while the inverse was found in the center of the brain (1.39388 ± 0.22056 seconds versus 1.42565 ± 0.21872 seconds, Cohen9s d = 0.14). Moreover, 7-delay had lower hemispheric asymmetry. CONCLUSIONS: The results of this study support the necessity of standardizing acquisition parameters in multidelay arterial spin-labeling and identifying basic parameters as a confounding factor in CBF quantification studies. Our findings conclude that multidelay arterial spin-labeling sequences with a high number of delays estimate higher CBF values than those with a lower number of delays.