MEMS (Micro Electro Mechanical System) switches were assessed and compared to PIN diode in fulfilling the task of active decoupling of Receiver Endoluminal Coils (RECs). Three prototype RECs with the PIN diode in parallel (pPIN), MEMS in parallel (pMEMS) and MEMS in series (sMEMS) with the REC loop were built. Quality factors (Q-values), decoupling efficiency and switching delays were characterized on bench and Signal-to-Noise Ratios (SNRs) established on images at 1.5 T. Q-values were equal to 62.5, 41.2 and 65.1 for pPIN, sMEMS and pMEMS, respectively. In the decoupled state, reflection coefficients S11 and S21 at resonance frequency both indicated proper decoupling. Switching delays were less than 0.7 μs and 10 μs for pPIN and MEMS RECs, respectively. Decoupling/coupling delays of MEMS remained compatible with most Magnetic Resonance (MR) clinical applications. For all prototypes, MR images displayed no signal saturation and similar elliptical image sensitivity patterns. No artifacts due to active decoupling failure were observed. Mean SNR values obtained with pMEMS REC were higher than those obtained with sMEMS REC but lower than with pPIN REC because of the use of additional instrumentation to render the scanner compatible with the MEMS utilization. MEMS in parallel are an interesting alternative to PIN diode for decoupling and could lead to better SNR with a compatible MR system (dedicated control signal). The MEMS in series can be used for both decoupling and reconfiguration of the REC loop geometry for colon wall examination.
The Instantaneous Signal Loss Simulation (InSiL) model is a promising alternative to the classical mono-exponential fitting of the Modified Look-Locker Inversion-recovery (MOLLI) sequence in cardiac T1 mapping applications, which achieves better accuracy and is less sensitive to heart rate (HR) variations. Classical non-linear least squares (NLLS) estimation methods require some parameters of the model to be fixed a priori in order to give reliable T1 estimations and avoid outliers. This introduces further bias in the estimation, reducing the advantages provided by the InSiL model. In this paper, a novel Bayesian estimation method using a hierarchical model is proposed to fit the parameters of the InSiL model. The hierarchical Bayesian modeling has a shrinkage effect that works as a regularizer for the estimated values, by pulling spurious estimated values toward the group-mean, hence reducing greatly the number of outliers. Simulations, physical phantoms, and in-vivo human cardiac data have been used to show that this approach estimates accurately all the InSiL parameters, and achieve high precision estimation of the T1 compared to the classical MOLLI model and NLLS InSiL estimation.
X-ray fluoroscopic imaging is the standard method for obtaining catheter position and monitoring the patient's vascular network during catheterization procedures. However, this method exposes both patients and doctors to ionizing radiation. To address this issue, we propose an alternative method for tracking the catheter inside the human body by integrating a magnetic sensor at the catheter tip and generating a known magnetic field (MF) around the operative zone. The catheter's position can then be determined by measuring this MF.Due to the mandatory small size of the catheter, we utilized giant-magnetoresistance (GMR) sensors for this tracking system. GMR sensors require only two wires for connection, have a wide bandwidth that allows flexibility in selecting the working frequency and can detect low-intensity MFs down to the nano Tesla range.Our method is based on the time detection of a moving null MF, known as the Field-Free Point (FFP) for MF generation. This approach requires only a single sensor smaller than 300 µm2, making it suitable for any catheter. We constructed an experimental setup to demonstrate the feasibility of this method in one dimension and obtained promising performance results.