Lorenzo Favero

Lorenzo Favero

Auto-generated profile, based on publicly available information

Lorenzo Favero

Università degli Studi di Padova, Italy

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
RFRiccardo Favero
Riccardo Favero
AVAndrea Volpato
Andrea Volpato
MFMaurizio De Francesco
Maurizio De Francesco
Adolfo Di FioreAdolfo Di Fiore
Adolfo Di Fiore
Riccardo GuazzoRiccardo Guazzo
Riccardo Guazzo
LFLorenzo Favero
Lorenzo Favero
Objective: The aim of the study was to verify and compare the accuracy of full-arch digital impressions obtained using two intraoral scanners and three scanning methodologies. Methods: A resin model created with dental 3-D printing was scanned by a reference scanner (Zfx Evolution - Zimmer Biomet, Palm Beach Gardens, FL) in order to obtain a 3D reference; the same resin model was then scanned with two different intraoral scanners (Zfx IntraScan and Carestream 3600 - CS 3600®, Carestream, Rochester, NY, USA) using: Technique A (from tooth #27 up to tooth #17); Technique B (from tooth #11 up to tooth #17 and then from tooth #21 up to tooth #27) and Technique C (from tooth #22 up to tooth #17, and then from tooth #12 up to tooth #27 - the MeshLab software v. 1.3.3 was then used to match the two scans). The scans obtained were superimposed over the reference scan by means of a software, and the volumetric discrepancies were calculated. Results: The mean results for the Zfx Intrascan scanner were: Technique A = 302.47 ± 37.42 µm; Technique B = 180.45 ± 29.86 µm; Technique C = 147.34 ± 28.23 µm. The mean results for the Carestream 3600 scanner were: Technique A = 303.59 ± 40.20 µm; Technique B = 181.53 ± 29.61 µm; Technique C = 142.28 ± 35.33 µm. Technique C, used by both scanners, produced less volumetric discrepancies compared to the other techniques. Conclusions: The scanning technique had a statistically significant effect on the quality of the scan (p< 0.0001), whereas the scanner did not present any significant influence (p= 0.91).

1 January 2023 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
RFRiccardo Favero
Riccardo Favero
LLLisa Libralato
Lisa Libralato
FBFrancesca Balestro
Francesca Balestro
AVAndrea Volpato
Andrea Volpato
LFLorenzo Favero
Lorenzo Favero
Introduction: Although the superiority of clear aligners over multi-bracket appliances in keeping gingiva healthy has been suggested, the possible benefits of one aligner design over another have not yet been investigated, especially with regard to the vestibular edge. Objective: The aim of this study was to measure several periodontal indexes in adolescents undergoing orthodontic treatment with aligners, comparing two different types of rim. Methods: The study involved 43 patients aged between 14 and 18 years. The periodontal health was assessed using plaque index (PI), gingival index (GI), and gingival bleeding index (GBI), at the start of the treatment with aligners (T0), with a vestibular rim (VR) reaching up to 3 mm beyond the gingival margin. Three months later (T1), aligners were set to obtain a juxtagingival rim (JR) on the second quadrant and VR on the first quadrant. The periodontal indexes were measured again, both at T1 and then three months later (T2). Results: Intra-quadrant comparisons revealed a statistically significant worsening of the periodontal indexes only for the second quadrant (p<0.05), at T1 (GI), and especially at T2 (PI, GI, GBI), while no statistically significant changes were found for the first quadrant. Conclusions: More severe mechanical irritation, especially during insertion and removal of the aligner, can explain the worsening inflammatory indexes with the JR. In addition, the pressure exerted by the JR on the gingival sulcus seemed to facilitate plaque deposition, whereas the VR had a protective effect, reducing the risk of mechanical trauma.