Departamento de Metal Mecánica, Tecnológico Nacional de México, Instituto Tecnológico de Querétaro, Av. Tecnológico s/n Esq. Gral. Mariano Escobedo, Col. Centro Histórico, Querétaro 76000, Mexico
Auto-generated profile, based on publicly available information
Isaac Hernández-Arriaga
Departamento de Metal Mecánica, Tecnológico Nacional de México, Instituto Tecnológico de Querétaro, Av. Tecnológico s/n Esq. Gral. Mariano Escobedo, Col. Centro Histórico, Querétaro 76000, Mexico
This research presents an experimental study on a scaled prototype of a bladeless wind turbine that operates based on the principle of vortex-induced vibrations (VIV-BWT) with the implementation of bio-inspired design of a columnar-cactus type mast. The aerodynamic performance of columnar-cactus type masts with different numbers of ribs was investigated and compared with that of a conventional cylindrical mast. The objective of this novel proposal is to maximize wind energy conversion efficiency through vortex-induced vibrations, thereby enhancing energy generation. The present study focuses on the geometry of the columnar-cactus type mast as a vortex generator, which significantly influences the performance of this type of VIV wind energy harvester. The findings reveal that the geometric configuration of the cactus-inspired mast and the mast angle promote vortex formation, leading to higher lift coefficients and forces. Consequently, this results in greater vortex-induced vibration magnitudes. For instance, at a wind speed of 6.0 m/s and a mast angle of 0°, the 6-rib cactus-type mast exhibits 12 times greater VIV amplitude compared to the conventional cylindrical mast, while the 5-rib and 7-rib cactus-type masts show 2.4- and 2.2-times greater amplitudes, respectively. However, for wind speeds below 5 m/s, the cylindrical mast demonstrates superior VIV performance.
Vortex-induced-vibration bladeless wind turbines exhibit limited energy-harvesting bandwidth because their aeroelastic response varies with wind speed. This study investigates a tunable turbine incorporating a variable-effective-length clamped–clamped beam spring with a theoretical stiffness range of 4500–30,000 N/m. An eight-state nonlinear model couples structural motion, electromagnetic conversion, and a bidirectional wake oscillator. Numerical benchmarking, frequency-domain analyses, and constrained optimization characterize the resulting dynamics. At 3 m/s, the optimized configuration generated 35.68 mW mean electrical power while satisfying lateral and axial displacement limits of 35 and 3 mm, respectively. Wind-speed-dependent tuning increased the mean power to 114.67 mW at 3.6 m/s. Using site-specific hourly wind data, estimated gross annual generation reached 140.29 Wh compared with 28.21 and 10.26 Wh for conventional and fixed-stiffness configurations, respectively. Estimated actuator consumption was 13.30 Wh annually. However, Monte Carlo simulations revealed joint robustness probabilities of only 1.5–3.5% under simultaneous parameter uncertainties. These findings demonstrate the potential of adaptive stiffness tuning while emphasizing the need for robust design, aerodynamic calibration, and experimental validation.
30 June 2022 in Journal Mathematical and Quantitative Methods
The research presents the calculation by numerical methods of the energy density for a typical vertical wind profile, which is obtained from data acquired by the Regional Center for Wind Technology (CERTE) in the region of Juchitán de Zaragoza, Oaxaca, Mexico. The vertical wind profile considered presents inhomogeneities in energy density and speed, unlike the controlled conditions in a laboratory with a wind tunnel. The energy density allows us to calculate correction factors on the measured parameters of a wind turbine when it is tested under free wind laboratory conditions. The correction factor for the power coefficient in a small wind turbine with a capacity to generate 30 kW of power, developed by CIATEQ AC Centro de Tecnología Avanzada, hypothetically measured under free wind conditions, is also shown. These correction factors can also be useful in estimating the power generated when laboratory conditions are not available.