Eva-Maria Dölker

Eva-Maria Dölker

Auto-generated profile, based on publicly available information

Eva-Maria Dölker

Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EDEva-Maria Dölker
Eva-Maria Dölker
SLStephan Lau
Stephan Lau
MBMaria Anne Bernhard
Maria Anne Bernhard
JHJens Haueisen
Jens Haueisen
Our long-term goal is the development of a wearable warning system that uses electrocutaneous stimulation. To find appropriate stimulation parameters and electrode configurations, we investigate perception amplitude thresholds and qualitative perceptions of electrocutaneous stimulation for varying pulse widths, electrode sizes, and electrode positions. The upper right arm was stimulated in 81 healthy volunteers with biphasic rectangular current pulses varying between 20 and $$2000\,\upmu \hbox {s}$$2000μs . We determined perception, attention, and intolerance thresholds and the corresponding qualitative perceptions for 8 electrode pairs distributed around the upper arm. For a pulse width of $$150\,\upmu \hbox {s}$$150μs , we find median values of 3.5, 6.9, and 13.8 mA for perception, attention, and intolerance thresholds, respectively. All thresholds decrease with increasing pulse width. Lateral electrode positions have higher intolerance thresholds than medial electrode positions, but perception and attention threshold are not significantly different across electrode positions. Electrode size between $$15 \times 15\,\hbox {mm}^{2}$$15×15mm2 and $$40\times 40\,\hbox {mm}^{2}$$40×40mm2 has no significant influence on the thresholds. Knocking is the prevailing perception for perception and attention thresholds while mostly muscle twitching, pinching, and stinging are reported at the intolerance threshold. Biphasic stimulation pulse widths between $$150\,\upmu \hbox {s}$$150μs and $$250\,\upmu \hbox {s}$$250μs are suitable for electric warning wearables. Within the given practical limits at the upper arm, electrode size, inter-electrode distance, and electrode position are flexible parameters of electric warning wearables. Our investigations provide the basis for electric warning wearables.

1 August 2022 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
EDEva-Maria Dölker
Eva-Maria Dölker
MBMaria Anne Bernhard
Maria Anne Bernhard
IDIndra Daniswara
Indra Daniswara
JHJens Haueisen
Jens Haueisen
Acoustic or visual warning signals for workers in hazardous situations might fail under loud and/or lowvisibility work situations. A warning system that uses electrocutaneous stimulation can overcome this problem. The aim of this pilot study was to find spatio-temporal stimulation patterns for appropriate electrical warning. Eight electrode pairs were attached to the upper right arm of 16 participants. The stimulation was conducted with bi-phasic rectangular pulses of 150 μs and an amplitude of up to 25 mA. Pulse intervals that generate a single pulse, pulsating, vibrating, and continuous perception as well as varying spatial patterns (e.g. alternating between electrode pairs or circumferentially around the arm) were investigated and evaluated with regard to alertness, discomfort, and urgency. The pilot study revealed that a stimulation signal that generates a vibrating perception and is applied as a circumferential signal around the arm showed the highest values of alertness and is therefore considered a potential warning pattern for future studies with larger study groups.

1 December 2024 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
EDEva-Maria Dölker
Eva-Maria Dölker
JHJens Haueisen
Jens Haueisen
Acoustic or visual warning signals for workers in hazardous situations might fail under loud and/or lowvisibility work situations. A warning system that uses electrocutaneous stimulation can overcome this problem. This study aimed to compare vertical, diagonal, and horizontal current stimulation directions at the upper arm to select the one with the lowest amount of muscle twitching. Fourteen electrodes were attached in two rows to the upper right arm of 15 participants. The stimulation was conducted with bi-phasic rectangular pulses of 150 μs and amplitudes of up to 25 mA. Muscle twitch thresholds have been determined and a circumferential stimulation signal was presented as warning pattern for the three current stimulation directions and evaluated regarding alertness, discomfort, and urgency. For single stimulation pulses, muscle twitches occurred slightly less often at the horizontal stimulation direction compared to the other two and muscle twitch thresholds showed no systematic differences. For the warning patterns, no considerable differences were found regarding the evaluation of alertness, discomfort, and urgency and no differences were found for muscle twitching. In conclusion, all orientations seem suitable for warning pattern presentation and none of the directions has a clear advantage in reducing muscle twitch.

4 November 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EDEva-Maria Dölker
Eva-Maria Dölker
DGDaniel Gröllich
Daniel Gröllich
MSMartin Schmauder
Martin Schmauder
JHJens Haueisen
Jens Haueisen
Electrocutaneous stimulation can be used to warn workers in hazardous situations. To determine parameters for the operating ranges of such warning systems we investigated the influences of vibrations, temperature, and humidity on the perception, attention, muscle twitch, and intolerance thresholds of healthy volunteers in a multi-center study. In a study on 94 participants, vibrations with amplitudes of 2 mm, 5 mm, and 8 mm and at frequencies of 8 Hz and 9.5 Hz were applied to the right arm. In a second study, 52 participants experienced temperature and humidity variations within a climate chamber in four conditions: dry cold (13.8 ± 1.6 $$^{\circ }$$ C, 33.9 ± 9.2% relative humidity (RH)), dry warm (41.3 ± 1.7 $$^{\circ }$$ C, 24.6 ± 5.8% RH), wet cold (12.0 ± 1.6 $$^{\circ }$$ C, 88.5 ± 8.2% RH), and wet warm (41.3 ± 2.1 $$^{\circ }$$ C, 65.5 ± 9.0% RH). In both studies, the upper right arm was electrically stimulated with electrodes of size 25 mm $$\times$$ 40 mm, and thresholds were determined. Perception, attention, and intolerance thresholds increased with vibration amplitude and frequency from median values of 5 mA, 9.9 mA and 19.3 mA for perception, attention and intolerance thresholds during rest to 14.6 mA, 20 mA and 21 mA during vibration amplitude of 8 mm and frequency of 9.5 Hz. Perception thresholds slightly increased with decreasing temperature with median values of 4.1 mA during dry cold vs. 3.8 mA during dry warm condition and 4.0 mA during wet cold vs. 3.8 mA during wet warm condition for an electrode pair at a lateral position. Muscle twitch thresholds slightly increased with increasing temperature at the lateral electrode pair with median values of 17.4 mA during dry cold vs. 18.8 mA during dry warm condition and 17.5 mA during wet cold vs. 18.7 mA during wet warm condition. For both studies, women showed smaller perception and attention thresholds. For illustration, in study 1, the median values of the perception threshold during rest were 4.1 mA for women and 5.7 mA for men, whereas the median values for the attention threshold were 9.1 mA for women and 11.4 mA for men, respectively. Additionally, women experienced less muscle twitching. To exemplify this, 50% of the women experienced muscle twitches compared to 66% of the men at a lateral electrode pair in study 2. We conclude that the operating range of future electrical warning systems needs to be flexibly adjusted to the working conditions. The influence of the climate conditions was minor, suggesting that electrocutaneous warning systems can operate robustly across diverse environments. This supports their practical applicability and motivates future research on optimized dry or textile-based electrodes to enhance usability in real-world settings.

1 December 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
BPBojana Petkovic
Bojana Petkovic
EDE. M. Dolker
E. M. Dolker
RSR. Schmidt
R. Schmidt
HTHannes Toepfer
Hannes Toepfer
JHJens Haueisen
Jens Haueisen

1 October 2018 in NDT & E International
Verified
Journal Article
Closed access
EDE.-M. Dölker
E.-M. Dölker
RSR. Schmidt
R. Schmidt
SGS. Gorges
S. Gorges
JOJ.M. Otterbach
J.M. Otterbach
BPB. Petković
B. Petković
JHJens Haueisen
Jens Haueisen