Kaisheng Mei

Kaisheng Mei

Auto-generated profile, based on publicly available information

Kaisheng Mei

National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xian, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCle cheng
le cheng
KMKaisheng Mei
Kaisheng Mei
ZCZhiqiang Chen
Zhiqiang Chen
WJWei Jia
Wei Jia
YWYi Wang
Yi Wang
WDWeidong Ding
Weidong Ding
In order to further improve the output voltage amplitude and repetitive operation reliability of nanosecond pulse generator (PG) based on avalanche transistor (AT), the method of power synthesis of modularized Marx circuits with transmission line transformer (TLT) is employed in this article. The modified positive $4\times11$ -stage Marx circuit introducing base-triggering method is designed and implemented to improve the operation reliability. The triggering synchronization and the consistence of output characteristics of multiple Marx modules with an identical trigger pulse are validated. The feasibility of combining pulses generated from four Marx modules with an optimized four-stage TLT is demonstrated. The influences of the type and quantity of magnetic core and the superimposed stage number of TLT on the output performance of the generator are investigated. The operation characteristics of the generator including output parameters, trigger time-delay, and loop efficiency in the whole working range are evaluated. The experimental results show that the working range of the overall device has been widened significantly with the injection of additional initial carrier. Accordingly, the generator prototype is capable of achieving the output performance with an adjustable voltage amplitude in the range of 7.8–26.7 kV on a matched 300- $\Omega $ resistive load and 12.2–38.9 kV on the high-resistance load, respectively, a 10%–90% rise time of 3.6 ns, and a full-width at half-maximum (FWHM) of 12.2 ns. A long-term test with the maximum repetition rate of 3 kHz is conducted to realize high-voltage output and high-frequency operation simultaneously.

18 May 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
TWTianchi Wang
Tianchi Wang
JLJunna Li
Junna Li
HWHaiyang Wang
Haiyang Wang
ZCZhiqiang Chen
Zhiqiang Chen
FGFan Guo
Fan Guo
WCWei Chen
Wei Chen
Megavolt-class pulsed gas switches play an important role in large pulsers as transfer switches. This article analyzes the breakdown process and characteristics of a megavolt self-triggered preionized switch under 100-ns pulses based on the optical diagnosis. It is discovered that the triggering spark illumination targeting the main cathode or anode can separately preionize the main gap. The discharge channel is likely to first form between trigger electrodes and the main anode. Based on the above deduction, the streamer velocity is calculated to be $0.54 \times 10^{6}$ – $2.34 \times 10^{6}$ m/s, proportional to the electric field. Also, parameters of the empirical formula for calculating the gas heating time are amended. Influence mechanisms of the switch jitter are also studied. Under pulsed preionization mode, the trigger gap breaks down when the main gap electric field is high enough, and the switch jitter is mainly determined by the self-triggering jitter. Nonetheless, the self-triggering jitter can be partly offset during the breakdown process if the changing rate of mean reduced electric field $d(E/p)$ / dt at the self-triggering time is higher than 1.0 $1.0\left(\mathrm{kV} \cdot \mathrm{ns}^{-1} \cdot \mathrm{cm}^{-1} \cdot \mathrm{MPa}^{-1}\right)$ . Under sustaining preionization mode, the trigger gap breaks down prematurely, and the continuous arcing driven by switch leak current preionizes the main gap. Therefore, the influence of the self-triggering jitter on the switch jitter can be eliminated.

4 August 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
CSChuyu Sun
Chuyu Sun
SJShengchang Ji
Shengchang Ji
LXLinshen Xie
Linshen Xie
HWHaiyang Wang
Haiyang Wang
KMKaisheng Mei
Kaisheng Mei
Surface flashover of dielectric materials often causes extensive damage to pulse power devices. Nowadays, this insulation issue is exacerbated by the demands for ever-higher operating voltages. To solve this issue, the flashover voltage and the streamer development characteristics were investigated under positive and negative nanosecond impulse, respectively, in pressured SF6 gas. First, the surface flashover strength was obtained and the Weibull distribution is introduced to describe the statistical characteristics. The results showed that the negative flashover voltage was much higher than the positive one for Al2O3-epoxy. Within the range of 0.1–0.3 MPa, the negative voltage increased with the gas pressure, while the positive one performed independent with pressure. Then, to investigate the streamer evolving process, a high-speed camera was used to get the discharge picture and the instant velocity of streamers at different conditions. Surface morphology change after the flashover was also analyzed. At last, the possible mechanisms for polarity and pressure effects were given.

22 November 2024 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
LCle cheng
le cheng
JXJing Xiao
Jing Xiao
GWGang Wu
Gang Wu
WWWei Wu
Wei Wu
KMKaisheng Mei
Kaisheng Mei
ZZZicheng Zhang
Zicheng Zhang
The threat of high-altitude electromagnetic pulse (HEMP) to electronic information equipment has received widespread attention. Specific to the performance evaluation testing requirements of subsystem-level equipment against the HEMP threat, a miniaturized vertical polarized bounded-wave simulator is designed and developed in this article. Based on the direct drive method wherein a fast compact Marx generator (CMG) discharges to a guided-wave antenna with a codesigned pulse-shaping switch, the developed simulator is capable of generating a standard HEMP radiation environment in a limited test volume and guaranteeing the consistency of peak field intensity with a fixed operation voltage. Integration of a self-steepening structure into the conventional CMG effectively improves the output pulse front edge by modulating the stray capacitance value. Consequently, the primary pulse output with an amplitude exceeding 220 kV and a rising time of less than 4.7 ns can be realized, significantly expanding the dynamic working range of the pulse-shaping switch. Additionally, the integrated design of the pulse-shaping switch and the radiation antenna ensures structure continuity, facilitating the distortionless transmission of the feeding voltage pulse. This modification enables the realization of the rising time of the radiation electric field extending from the standard 2.5 ± 0.5 ns to the subnanosecond range. The simulator can generate an electromagnetic environment with a maximum electric field intensity surpassing 100 kV/m and a field uniformity of 2.8 dB. This article provides a fresh perspective on the design of a compact and reliable bounded-wave HEMP simulator.

1 November 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
ZCZhiqiang Chen
Zhiqiang Chen
WJWei Jia
Wei Jia
WWWei Wu
Wei Wu
KMKai-Sheng Mei
Kai-Sheng Mei
FGFan Guo
Fan Guo
WWWei Wang
Wei Wang
Coaxial peaking capacitor is a key component in high-altitude electromagnetic pulse (EMP) simulators with fast front pulse output. It poses significant technical and engineering challenges in limiting radiation field amplitude and test space. This paper presents the design and testing of a 180 pF, 3 MV coaxial peaking capacitor with improved insulation performance. In the insulation design, the length of the dielectric film is extended to reduce the background electric field on the flashover path. The electric field threshold obtained from image diagnosis is used as a reference. During capacitor testing, the insulation characteristics are diagnosed using both direct and indirect methods. The voltage measured by a D-dot probe, the output waveform of the Marx generator in the primary source, and the radiation field waveform are analyzed to understand the flashover characteristics of the capacitor and to improve the reliability of the test results. The experimental results demonstrate that the peaking capacitor can operate stably at 3.0 MV. If flashover occurring on the dropping edge of the pulse is permitted, the operating voltage can be greater than 3.7 MV without significantly affecting the radiation field waveform. The analysis on the surface flashover morphology of the peaking capacitor reveals that the flashover mainly occurs at the dropping edge of the capacitor's waveform, indicating that the damage to the film is not serious. This research significantly increases the working voltage of coaxial peaking capacitors and contributes to the development of high-altitude EMP simulation technology.

31 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
WJWei Jia
Wei Jia
KMKaisheng Mei
Kaisheng Mei
LCle cheng
le cheng
WWWei Wu
Wei Wu
ZCZhiqiang Chen
Zhiqiang Chen
YLYaoyao Li
Yaoyao Li
In this paper, the design of a self-developed EMP simulator with a 5 m height and an inverted conducting mono-cone antenna with a cone half-angle of 32° is introduced. The experimental region of the simulator is a circular area of 25 m in diameter around the cone vertex. Two feeding modes, feed-in over the ground and feed-in under the ground, are realized by two different high-voltage pulse sources. It can be concluded through radiation field testing that the radiation field waveform generated by the simulator has a rise time of 2–3 ns and a half-width of about 25 ns, meeting the specifications of the EMP experimental waveform in the IEC61000-2-9 standard. Meanwhile, the differences between the engineering implementation of the simulator and its ideal structure during the design process can lead to some distortion issues in the antenna radiation characteristics and the electromagnetic radiation field it generates. The radiation field waveform and the distribution of the EMP field generated by the simulator under different feeding methods, antenna wire quantities, antenna end processing methods, and different antenna resistive loading were studied, and the changes in the radiation field waveform and field distribution with different angles and distances of the monitoring point were analyzed. Based on the measurement results, the radiation characteristics of the antenna and the factors that affect the waveform of the field were studied and analyzed. Through the aforementioned work, a comprehensive understanding of the performance, radiation characteristics, and engineering factors affecting the electromagnetic environment generated by the simulator has been obtained. On this basis, the parameters of the antenna wire quantity, antenna end processing method, and test point position of the designed simulator were reconfirmed and optimized. In summary, this work has important reference significance for mastering the development technology of such simulators, understanding their antenna radiation characteristics, and conducting EMP-related assessments and effect experiments in the future.