Heng Wei

Heng Wei

Auto-generated profile, based on publicly available information

Heng Wei

Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RARashid Alavi
Rashid Alavi
AAArian Aghilinejad
Arian Aghilinejad
HWHeng Wei
Heng Wei
SNSoha Niroumandi
Soha Niroumandi
SWSeth Wieman
Seth Wieman
Niema PahlevanNiema Pahlevan
Niema Pahlevan
In-vitro models of the systemic circulation have gained a lot of interest for fundamental understanding of cardiovascular dynamics and for applied hemodynamic research. In this study, we introduce a physiologically accurate in-vitro hydraulic setup that models the hemodynamics of the coupled atrioventricular-aortic system. This unique experimental simulator has three major components: 1) an arterial system consisting of a human-scale artificial aorta along with the main branches, 2) an artificial left ventricle (LV) sac connected to a programmable piston-in-cylinder pump for simulating cardiac contraction and relaxation, and 3) an artificial left atrium (LA). The setup is designed in such a way that the basal LV is directly connected to the aortic root via an aortic valve, and to the LA via an artificial mitral valve. As a result, two-way hemodynamic couplings can be achieved for studying the effects that the LV, aorta, and LA have on each other. The collected pressure and flow measurements from this setup demonstrate a remarkable correspondence to clinical hemodynamics. We also investigate the physiological relevancies of isolated effects on cardiovascular hemodynamics of various major global parameters found in the circulatory system, including LV contractility, LV preload, heart rate, aortic compliance, and peripheral resistance. Subsequent control over such parameters ultimately captures physiological hemodynamic effects of LV systolic dysfunction, preload (cardiac) diseases, and afterload (arterial) diseases. The detailed design and fabrication of the proposed setup is also provided.

13 June 2023 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AAArian Aghilinejad
Arian Aghilinejad
HWHeng Wei
Heng Wei
CBCoskun Bilgi
Coskun Bilgi
APAlberto Paredes
Alberto Paredes
ADAlexander DiBartolomeo
Alexander DiBartolomeo
Niema PahlevanNiema Pahlevan
Niema Pahlevan
Type B aortic dissection is a life-threatening medical emergency that can result in rupture of the aorta. Due to the complexity of patient-specific characteristics, only limited information on flow patterns in dissected aortas has been reported in the literature. Leveraging the medical imaging data for patient-specific in vitro modeling can complement the hemodynamic understanding of aortic dissections. We propose a new approach toward fully automated patient-specific type B aortic dissection model fabrication. Our framework uses a novel deep-learning-based segmentation for negative mold manufacturing. Deep-learning architectures were trained on a dataset of 15 unique computed tomography scans of dissection subjects and were blind-tested on 4 sets of scans, which were targeted for fabrication. Following segmentation, the three-dimensional models were created and printed using polyvinyl alcohol. These models were then coated with latex to create compliant patient-specific phantom models. The magnetic resonance imaging (MRI) structural images demonstrate the ability of the introduced manufacturing technique for creating intimal septum walls and tears based on patient-specific anatomy. The in vitro experiments show the fabricated phantoms generate physiologically-accurate pressure results. The deep-learning models also show high similarity metrics between manual segmentation and autosegmentation where Dice metric is as high as 0.86. The proposed deep-learning-based negative mold manufacturing method facilitates an inexpensive, reproducible, and physiologically-accurate patient-specific phantom model fabrication suitable for aortic dissection flow modeling.

13 January 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AAArian Aghilinejad
Arian Aghilinejad
HWHeng Wei
Heng Wei
Niema PahlevanNiema Pahlevan
Niema Pahlevan
Objective: The clinical significance of the wave intensity (WI) analysis for the diagnosis and prognosis of the cardiovascular and cerebrovascular diseases is well-established. However, this method has not been fully translated into clinical practice. From practical point of view, the main limitation of WI method is the need for concurrent measurements of both pressure and flow waveforms. To overcome this limitation, we developed a Fourier-based machine learning (F-ML) approach to evaluate WI using only the pressure waveform measurement. Methods: Tonometry recordings of the carotid pressure and ultrasound measurements for the aortic flow waveforms from the Framingham Heart Study (2640 individuals; 55% women) were used for developing the F-ML model and the blind testing. Results: Method-derived estimates are significantly correlated for the first and second forward wave peak amplitudes (Wf1, r=0.88, p $< $ 0.05; Wf2, r=0.84, p $< $ 0.05) and the corresponding peak times (Wf1, r=0.80, p<0.05; Wf2, r=0.97, p $< $ 0.05). For backward components of WI (Wb1), F-ML estimates correlated strongly for the amplitude (r=0.71, p $< $ 0.05) and moderately for the peak time (r=0.60, p $< $ 0.05). The results show that the pressure-only F-ML model significantly outperforms the analytical pressure-only approach based on the reservoir model. In all cases, the Bland-Altman analysis shows negligible bias in the estimations. Conclusion: The proposed pressure-only F-ML approach provides accurate estimates for WI parameters. Significance: The pressure only F-ML approach introduced in this work expand the clinical usage of WI into inexpensive and non-invasive settings such as wearable telemedicine.

16 December 2021 in Physical Review Fluids
Verified
Journal Article
Closed access
PDF file
HWHeng Wei
Heng Wei
CHCynthia S. Herrington
Cynthia S. Herrington
JCJohn D. Cleveland
John D. Cleveland
VSVaughn A. Starnes
Vaughn A. Starnes
Niema PahlevanNiema Pahlevan
Niema Pahlevan
Infants born with single-ventricle physiologies pose significant challenges for mechanical circulatory support devices. Their corresponding Fontan circulations consist of passive blood flow that returns to the lungs via direct connections to the pulmonary arteries without a pumping chamber. When Fontan patients reach adolescence or young adulthood, they tend to develop heart failure and may require heart transplants and/or mechanical assist devices. Mechanical supports often require a reservoir to attach, but no such blood reservoir exists in a closed Fontan circulation. This study was aimed to investigate the existence of a hemodynamically optimized geometry for an artificial right atrium (ARA) that can act as a reservoir for circulatory support in Fontan patients. Our hemodynamics-based criteria for an ARA were defined as minimum particle residence time (PRT) (to reduce the probability of blood clot formation) and maximum volume compliance (to prevent pressurization of cerebral and hepatic veins). A computational approach was used to complete this study. We utilized non-Newtonian fluid-solid interaction simulations constructed by lattice-Boltzmann and immersed boundary methods. Our results show that a hemodynamically optimum shape for an ARA with minimum PRT (relative to the cases considered in this study) is convex at the outlet (towards the lungs) and concave at the opposite side of the outlet. Additionally, the optimal ARA geometry well preserves the volume compliance that is needed to prevent pressurization of cerebral and/or hepatic veins. Interestingly, this shape resembles that of the healthy anatomical right atrium. Future implantation of our proposed ARA configuration may potentially lessen the risk of implementing biventricular supports in Fontan patients.

23 June 2025 in European Heart Journal Open
Verified
Journal Article
Open access
SNSoha Niroumandi
Soha Niroumandi
HWHeng Wei
Heng Wei
FAFaisal Amlani
Faisal Amlani
HGHossein Gorji
Hossein Gorji
RARashid Alavi
Rashid Alavi
Niema PahlevanNiema Pahlevan
Niema Pahlevan
Aims: Clinical studies show that pulsatile haemodynamics and pressure waveform analysis are valuable for the diagnosis and prognosis of hypertension and heart failure (HF). While generalized transfer functions (GTFs) have shown clinical significance, some studies report limitations with GTF in capturing central pulsatile haemodynamics. This study introduces a hybrid time-frequency, machine learning-based transfer function that reconstructs central pressure waveforms from peripheral measurements, accurately capturing central pulsatile haemodynamics and arterial wave-based information. Methods and results: Our method uses Fourier harmonics for approximating the pressure waveform. The model is trained on these harmonics using a feed-forward neural network (FNN) with a custom time-domain cost function that captures the full temporal dynamics of physiological events during a cardiac cycle. The final hybridized-FNN transfer function model is trained, tested, and validated on data from the Framingham Heart Study (6698 participants). Our method produces carotid waveforms with median normalized mean squared error (%NMSE) values of 0.09 and 0.10 for brachial and radial inputs, compared to 0.42 and 0.26 for GTF, with similar accuracy improvements in other metrics. Correlation coefficients for the first and second forward wave times and amplitudes are 0.97, 0.93, 0.82, and 0.79 with brachial input, and 0.97, 0.92, 0.87, and 0.80 with radial input, vs. as low as 0.22 and 0.31 for GTF. Overall, our method significantly improved correlations across similarity, morphology, and wave-based parameters. Conclusion: Our hybridized FNN transfer function approach enables robust calculation of the central arterial pressure waveform from a single measured peripheral waveform, preserving key physiological sequences in a cardiac cycle.

1 October 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
HWHeng Wei
Heng Wei
DHDavid A. Hutchins
David A. Hutchins
PRPaul Ronney
Paul Ronney
Niema PahlevanNiema Pahlevan
Niema Pahlevan
In tropical and subtropical ocean gyres, Trichodesmium colonies account for up to half of the total N2 fixation in the ocean, making it one of the most ecologically significant N2-fixing cyanobacteria. The processes whereby Trichodesmium colonies and large-scale surface blooms form have not been investigated thoroughly. In particular, the effects of fluid motion have not been included in previous studies. As the first step toward understanding the mechanical processes associated with Trichodesmium colony synthesis, we propose a shear-related flow-based growth model to enlighten how fluid dynamics affect bacteria colony formation and growth. To investigate the possibility that early growth characteristics are strongly dependent on the shear rate, a two-way coupled fluid-colony interaction is developed using the lattice Boltzmann method for a porous colony. This model captures the exponential growth trend during the colony formation phase found in experiments. Our results show that the flow field significantly impacts both the colony growth rate and shape. In pure shear conditions, colonies grow in circular shapes, whereas in uniform flow, they take filament-like forms. Additionally, the Reynolds number (Re) plays a crucial role in shaping the colonies, especially in uniform flow conditions where its effect is more profound.