4 March 2016 in Biotechnology & Biotechnological Equipment
Cortical bone is an inhomogeneous and anisotropic tissue subjected to large loads during typical daily activities. While studies assuming isotropic material properties are frequent, anisotropy and inhomogeneity of cortical bone have been rarely taken into account. Moreover, the question, whether an assumption of anisotropy and inhomogeneity has an impact in the mechanical analysis of cortical bone, has not been explored in the literature. This study explores the relevance of anisotropy in human cortical bone. The cortical bone model has been divided into six radial regions and a different set of orthotropic material properties has been assigned to each region. This inhomogeneous and anisotropic elastic tibia model has been compared with a corresponding isotropic model under various loading modes using the finite element method. In particular, the variation in the maximum von Mises stress and strain values has been observed along the bone axis. We have observed that the isotropic model may overestimate the maximum von Mises strain up to 15% under pure compression and underestimate up to 50% under pure torsion relative to the inhomogeneous–anisotropic model. Our results suggest that consideration of anisotropy and inhomogeneity of the bone may make a significant difference in the predicted maximum von Mises strain values, which can be important for strain-based damage accumulation studies and fracture risk evaluation.
1 January 2021 in Computer Methods and Programs in Biomedicine
4 October 2019 in Medical Engineering & Physics
A knowledge of material properties of soft tissue, such as articular cartilage, is essential to assess its mechanical function. It is also increasingly more evident that the inhomogeneity of the tissues plays a significant role in its in vivo functioning. Hence, efficient and reliable tools are needed to accurately characterize the inhomogeneity of the soft tissue mechanical properties. The objective of this research is to propose a finite element optimization procedure to determine depth-dependent material properties of articular cartilage by processing experimental data. Cartilage is modeled as a biphasic continuum with a linear elastic solid phase. The optimization method is based on a sensitivity analysis where the sensitivity of the finite element results to a variation in the material properties is analytically evaluated. The elastic modulus and permeability of the tissue are assumed to vary either linearly or quadratically through the thickness of the cartilage layer. After adopting some initial estimates, these material properties are updated iteratively based on their sensitivities to the current results, and the difference between the actual experimental data and computational experimental data. The optimization method has been tested in two common experimental configurations of cartilage and found to be efficient to estimate the material properties.
11 September 2006 in Journal of Medical Devices
The objective of this work is to set up, validate, and analyze a theoretical model of an external fixator for its deformation characteristics in order to draw reliable conclusions relevant to the design and effective clinical implementation of such medical devices. External fixators are mechanical devices widely used in the treatment of fractured bones and correction of limb deformities. Lateral deformation at the fracture site is known to delay bone healing, and investigation of lateral deformation characteristics of such devices experiencing forces acting perpendicular to the bone axis is important from the standpoint of their design as well as their clinical effectiveness. A mathematical model of a three-dimensional (3D) unilateral fixator with multipin fragment attachments has been developed using Castigliano’s method. The relative lateral deformations of the fragment ends at the fracture site induced by loads applied perpendicular to bone axes are calculated with the model. The model has been subjected to experimental verification for a uniplanar unilateral external fixator under comparable conditions with the theory. It has been found out that the effects of fixator size, shape, and geometry on the level of relative lateral displacement of the fracture site are similar in both the theoretical and experimental models. Stiffness is a maximum if the force is applied in the same plane as the proximal pin plane. Placing the distal pin group at a 90deg position relative to the proximal pin plane has been observed to increase the stiffness about 10%. In loading directions perpendicular to proximal the pin plane, stiffness is minimum. The angle difference between the load direction and the resulting displacement direction follows a sinusoidal pattern with an amplitude of 10deg for loading angles in the 0–180deg range. Selecting the distance of proximal pins to the fracture site smaller than the distance of distal pins to the fracture site has been found to decrease relative lateral deformation. The model and the experiment have simultaneously demonstrated that lower values of effective pin lengths and higher values of pin connector lengths lead to higher stiffness. Increasing the number of pins also contributes to the higher values of fixator stiffness.
9 November 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Objective: When a signal is initiated in the nerve, it is transmitted along each nerve fiber via an action potential (called single fiber action potential (SFAP)) which travels with a velocity that is related with the diameter of the fiber. The additive superposition of SFAPs constitutes the compound action potential (CAP) of the nerve. The fiber diameter distribution (FDD) in the nerve can be computed from the CAP data by solving an inverse problem. This is usually achieved by dividing the fibers into a finite number of diameter groups and solve a corresponding linear system to optimize FDD. However, number of fibers in a nerve can be measured sometimes in thousands and it is possible to assume a continuous distribution for the fiber diameters which leads to a gradient optimization problem. In this work, we have evaluated this continuous approach to the solution of the inverse problem. Method: We have utilized an analytical function for SFAP and an assumed a polynomial form for FDD. The inverse problem involves the optimization of polynomial coefficients to obtain the best estimate for the FDD. Results: We have observed that an 8th order polynomial for FDD can capture both unimodal and bimodal fiber distributions present in vivo, even in case of noisy CAP data. Conclusion: The assumed FDD distribution regularizes the ill-conditioned inverse problem and produces good results.
23 May 2024 in The International Journal of Medical Robotics and Computer Assisted Surgery
Background: In the field of orthopaedics, external fixators are commonly employed for treating extremity fractures and deformities. Computer‐assisted systems offer a promising and less error‐prone treatment alternative to manual fixation by utilising a software to plan treatments based on radiological and clinical data. Nevertheless, existing computer‐assisted systems have limitations and constraints.Methods: This work represents the culmination of a project aimed at developing a new automatised fixation system and a corresponding software to minimise human intervention and associated errors, and the developed system incorporates enhanced functionalities and has fewer constraints compared to existing systems.Results: The automatised fixation system and its graphical user interface (GUI) demonstrate promising results in terms of accuracy, efficiency, and reliability.Conclusion: The developed fixation system and its accompanying GUI represent an improvement in computer‐assisted fixation systems. Future research may focus on further refining the system and conducting clinical trials.