Jaroslav Cerovsky

Jaroslav Cerovsky

Auto-generated profile, based on publicly available information

Jaroslav Cerovsky

Ceske Vysoke Uceni Technicke v Praze Fakulta jaderna a fyzikalne inzenyrska

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2023 in Measurement Science and Technology
Verified
Journal Article
Open access
AMA Dal Molin
A Dal Molin
Massimo NocenteMassimo Nocente
Massimo Nocente
MRM Dalla Rosa
M Dalla Rosa
EPE Panontin
E Panontin
DRD Rigamonti
D Rigamonti
VKV Kiptily
V Kiptily
Runaway electron gamma-ray detection system, a novel hard x-ray (HXR) spectrometer optimized for bremsstrahlung radiation measurement from runaway electrons in fusion plasmas, has been developed. The detector is based on a 1‘×1’ LaBr3:Ce scintillator crystal coupled with a photomultiplier tube. The system has an energy dynamic range exceeding 20 MeV with an energy resolution of 3% at 661.7 keV. The detector gain is stable even under severe loads, with a gain shift that stays below 3% at HXR counting rates in excess of 1 MCps. The performance of the system enables unprecedented studies of the time-dependent runaway electron energy distribution function, as shown in recent runaway electron physics experiments at the ASDEX Upgrade and COMPASS tokamaks.

1 November 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JCJ. Caloud
J. Caloud
ETE. Tomesova
E. Tomesova
OFOndřej Ficker
Ondřej Ficker
JCJ. Cerovsky
J. Cerovsky
JMJ. Mlynar
J. Mlynar
CTCompass Team
Compass Team
Runaway electrons, accelerated in a tokamak discharge to high energies (tens of MeV), can cause serious damage to plasma facing components. Therefore, it is important to develop effective mitigation strategies to reduce the risk of tokamak damage. To study the effects of various mitigation strategies, a dedicated diagnostic, the calorimetry probe, was developed at the COMPASS tokamak. This probe successfully measured the heat loads caused by runaway electrons directly, using a set of temperature sensors embedded in a graphite body. Deposited energy measured by the probe ranged from a few hundred joules up to (15 ± 1) kJ, while the mean deposited energy was (4.5 ± 1.1) kJ. The design of the probe and the initial results from 250 discharges covering four experimental campaigns dedicated to runaway electron studies (2019–2021) are presented in this article.

1 September 2025 in Review of Scientific Instruments
Verified
Journal Article
Open access
LSL. Simons
L. Simons
JCJ. Cerovsky
J. Cerovsky
JDJ. Decker
J. Decker
BDB. P. Duval
B. P. Duval
OFOndřej Ficker
Ondřej Ficker
TTTcv Team
Tcv Team
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼8MeV on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.

16 June 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
MTMarek Tunkl
Marek Tunkl
LLLukáš Lobko
Lukáš Lobko
ŠMŠtěpán Malec
Štěpán Malec
OFOndřej Ficker
Ondřej Ficker
JCJaroslav Cerovsky
Jaroslav Cerovsky
GPGergo I Pokol
Gergo I Pokol
Runaway electron (RE) losses are usually diagnosed with a small number of hard X-ray (HXR) detectors, which provide limited spatial information. Although multi-chord HXR spectrometers on large devices allow reconstruction of RE parameters in the plasma volume, equivalent methods for localized RE losses at plasma-facing components are scarce. We investigated the feasibility of inferring the RE strike-point position and in principle, pitch from bremsstrahlung generated at the poloidal limiter of the GOLEM tokamak. Geant4 simulations were used to construct a forward model, and synthetic detector signals were inverted with a tomographic algorithm. Benchmark tests indicated that strike-point localization should be possible with modest detector coverage, but pitch inference requires substantially more. With only five detectors available, we were able to demonstrate strike-point localization but no pitch estimation in the experiment. The results demonstrate the potential of thick-target bremsstrahlung as a diagnostic of RE losses.

28 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MVMárton Vavrik
Márton Vavrik
Tamás Zoltán SzepesiTamás Zoltán Szepesi
Tamás Zoltán Szepesi
GCGábor Cseh
Gábor Cseh
GKGábor Kocsis
Gábor Kocsis
JCJaroslav Cerovsky
Jaroslav Cerovsky
NPN. Panadero
N. Panadero
COMPASS Upgrade (COMPASS-U) [1] is a high-magnetic field (5 T) tokamak, currently being built at the Institute of Plasma Physics in Prague. The HUN-REN Centre for Energy Research plans to develop a pellet injector for COMPASS-U. This work aims to optimize the pellet injector parameters - pellet velocity, size, injection direction, and investigates the pellet-plasma interaction, using various plasma scenarios of the Compass Upgrade tokamak with the HPI2 code [2]. HPI2 is a widely used pellet injection simulation code that can handle 3D geometries and related secondary phenomena, like inhomogeneous pellet ablation.The dependence of material deposition and penetration depth on pellet size and velocity were examined, and for the desired material deposition, pellets with a radius of 0.75 mm should be injected into the plasma. Higher injection velocity is advantageous, but based on technical considerations, simulations were run using an injection velocity of 500 m/s.The properties of different injection directions were explored, in several scenarios, from early L-mode to the high-performance H-mode scenario, based on which the optimal injection geometry of the pellet injector was defined. While LFS injection is the easiest to realize technically, it results in the least efficient fuelling, as expected, as drift phenomena quickly accelerates the pellet cloud out from the plasma. The internal, HFS injection is the most efficient, where the drift direction points inward the plasma; due to accessibility constraints, pellets cannot be delivered here. A good compromise is the vertical (VHFS) injection, from an existing port. Relaxation of the plasma profiles after the injection were also investigated to characterise the pacing requirements of the injection.[1]: M. Komm et al, COMPASS Upgrade: a high-field tokamak for ITER- and DEMO-relevant research (2024) Nucl. Fusion 64 076028[2]: F. Koechl et al, Modelling of Pellet Particle Ablation and Deposition: The Hydrogen Pellet Injection code HPI2 (2014), EFDA–JET–PR(12)57, Nuclear Fusion

20 February 2024 in Fusion Engineering and Design
Verified
Journal Article
Closed access
JCJ. Cerovsky
J. Cerovsky
OFOndřej Ficker
Ondřej Ficker
JMJ. Mlynar
J. Mlynar
ETE. Tomesova
E. Tomesova
JCJ. Cavalier
J. Cavalier
MHM. Hron
M. Hron