Kenichi Sawauchi

Kenichi Sawauchi

Auto-generated profile, based on publicly available information

Kenichi Sawauchi

Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
YYYuya Yamamoto
Yuya Yamamoto
TFTOMOAKI FUKUI
TOMOAKI FUKUI
KSKenichi Sawauchi
Kenichi Sawauchi
RYRyo Yoshikawa
Ryo Yoshikawa
KTKyohei Takase
Kyohei Takase
KOKeisuke Oe
Keisuke Oe
Aims: Continuous local antibiotic perfusion (CLAP) has recently attracted attention as a new drug delivery system for orthopaedic infections. CLAP is a direct continuous infusion of high-concentration gentamicin (1,200 μg/ml) into the bone marrow. As it is a new system, its influence on the bone marrow is unknown. This study aimed to examine the effects of high-concentration antibiotics on human bone tissue-derived cells.Methods: Cells were isolated from the bone tissue grafts collected from six patients using the Reamer-Irrigator-Aspirator system, and exposed to different gentamicin concentrations. Live cells rate, apoptosis rate, alkaline phosphatase (ALP) activity, expression of osteoblast-related genes, mineralization potential, and restoration of cell viability and ALP activity were examined by in vitro studies.Results: The live cells rate (the ratio of total number of cells in the well plate to the absorbance-measured number of live cells) was significantly decreased at ≥ 500 μg/ml of gentamicin on day 14; apoptosis rate was significantly increased at ≥ 750 μg/ml, and ALP activity was significantly decreased at ≥ 750 μg/ml. Real-time reverse transcription-polymerase chain reaction results showed no significant decrease in the ALP and activating transcription factor 4 transcript levels at ≥ 1,000 μg/ml on day 7. Mineralization potential was significantly decreased at all concentrations. Restoration of cell viability was significantly decreased at 750 and 1,000 μg/ml on day 21 and at 500 μg/ml on day 28, and ALP activity was significantly decreased at 500 μg/ml on day 28.Conclusion: Our findings suggest that the exposure concentration and duration of antibiotic administration during CLAP could affect cell functions. However, further in vivo studies are needed to determine the optimal dose in a clinical setting.Cite this article: Bone Joint Res 2024;13(3):91–100.

27 December 2024 in Patient Safety in Surgery
Verified
Journal Article
Open access
PDF file
KSKenichi Sawauchi
Kenichi Sawauchi
LELuca Esposito
Luca Esposito
YKYannik Kalbas
Yannik Kalbas
ZAZygimantas Alasauskas
Zygimantas Alasauskas
VNValentin Neuhaus
Valentin Neuhaus
Ass Prof. Dr. Roman PfeiferAss Prof. Dr. Roman Pfeifer
Ass Prof. Dr. Roman Pfeifer
Hemodynamically unstable pelvic ring fractures from high-energy trauma are critical injuries in trauma care, requiring urgent intervention and precise diagnostics. With ongoing advancements in trauma management, treatment strategies have evolved, with some techniques becoming obsolete as new ones emerge. This study aimed to evaluate changes and trends in treatment algorithms for these injuries over approximately 40 years. A systematic review of PubMed and EMBASE was conducted to include articles published over roughly four decades that presented visual treatment algorithms or workflows for managing unstable pelvic ring fractures. Identified algorithms were categorized by publication period and analyzed by initial assessment, diagnostic methods, pelvic stabilization, and hemorrhage control interventions. The search identified 5,434 publications, of which 32 met the inclusion criteria. 75% of these studies were published between 2011 and 2022, reflecting a growing focus on standardization, particularly in Europe, North America, and Asia. Physiological assessment remains essential in the initial management of hemodynamically unstable pelvic ring fractures, guiding resuscitation and influencing the selection of intervention and imaging. The use of pelvic binders or sheets has risen steadily, highlighting their role in hemorrhage control and temporary stabilization. CT scans and angiography have largely replaced pelvic X-rays in diagnostic protocols, becoming preferred radiological methods alongside focused assessment with sonography for trauma (FAST). Pelvic stabilization remains critical, with external fixation being the most commonly used technique, showing an upward trend in recent years. Laparotomy, pelvic packing, and angioembolization continue to play vital roles in hemorrhage management. Emerging techniques, such as resuscitative endovascular balloon occlusion of the aorta (REBOA), anterior subcutaneous internal fixation (INFIX), and rescue screws, are increasingly included in treatment algorithms, while diagnostic peritoneal lavage (DPL) has become obsolete and is no longer listed in these algorithms. This review provides foundational insights toward the standardization of initial treatment for hemodynamically unstable pelvic ring fractures and holds significant importance in enhancing the consistency and efficiency of treatment. Future research should focus on accumulating higher-quality evidence to evaluate the effectiveness of standardized protocols and explore the applicability of new treatment methods.

2 August 2024 in American Journal of Case Reports
Verified
Journal Article
Open access
KSKenichi Sawauchi
Kenichi Sawauchi
TFTOMOAKI FUKUI
TOMOAKI FUKUI
KOKeisuke Oe
Keisuke Oe
RKRyosuke Kuroda
Ryosuke Kuroda
Takahiro NiikuraTakahiro Niikura
Takahiro Niikura
AMAkihiro Maruo
Akihiro Maruo
Management of Infected Tibial Nonunion: Combining Synthetic Bone Grafting with Continuous Local Antibiotic Perfusion (CLAP) - Article abstract #945023

27 September 2024 in Patient Safety in Surgery
Verified
Journal Article
Open access
PDF file
FKFelix Karl Ludwig Klingebiel
Felix Karl Ludwig Klingebiel
KSKenichi Sawauchi
Kenichi Sawauchi
AMAnne Mittlmeier
Anne Mittlmeier
YKYannik Kalbas
Yannik Kalbas
TBTill Berk
Till Berk
Ass Prof. Dr. Roman PfeiferAss Prof. Dr. Roman Pfeifer
Ass Prof. Dr. Roman Pfeifer
The management of hemodynamically unstable pelvic ring injuries necessitates surgical intervention, often involving procedures such as external fixation and percutaneous screw placement. Given the infrequent performance of these procedures, regular training is imperative to ensure readiness for emergencies. Our pre- post simulation study aimed to adapt and validate a realistic simulation model for stabilizing unstable pelvic ring injuries, facilitating participants’ knowledge retention and procedural confidence enhancement. A standardized simulator of an unstable pelvic ring utilizing synthetic pelvic bones featuring complete disruption of the symphysis and sacroiliac joint was developed. Trauma surgeons of a level one academic hospital were invited to perform external fixation and emergency sacroiliac screw application under C-arm guidance. Prior to and following the simulation session, participants completed a subjective questionnaire assessing their confidence in emergency interventions on a 10-point Likert scale (10-LS). Objective parameters, such as intraoperative imaging quality, reduction accuracy, and the positioning of screws, wires, and external fixators, were also evaluated as secondary outcome measures. Fifteen trauma surgeons (10 residents, 5 consultants) participated in the simulation over the course of one day. The mean total operation time was 20.34 ± 6.06 min, without significant differences between consultants and residents (p = 0.604). The confidence for emergency SI-Screw placement increased significantly after the simulator (10-LS: Before = 3.8 ± 3.08 vs. After = 5.67 ± 2.35; p = 0.002) as well as after external fixation (10-LS: Before = 3.93 ± 2.79 vs. After = 6.07 ± 2.52; p = 0.002). In addition, confidence in (intraoperative) pelvic imaging increased significantly (10-LS: Before = 4.60 ± 3.0 vs. After = 6.53 ± 2.39; p = 0.011). Overall, the model was rated as a realistic simulation of clinical practice (10-LS = 7.87 ± 1.13). Our unstable pelvis fracture model is a tool to practice emergency interventions such as external fixation and percutaneous techniques. Participants benefitted from this in terms of technical instrumentation as well as intraoperative imaging. Further studies are required to validate the objective benefits and improvements that participants undergo through frequent training.

26 February 2025 in American Journal of Case Reports
Verified
Journal Article
Open access
KSKenichi Sawauchi
Kenichi Sawauchi
KOKeisuke Oe
Keisuke Oe
TFTOMOAKI FUKUI
TOMOAKI FUKUI
YKYohei Kumabe
Yohei Kumabe
HMHirotsugu Muratsu
Hirotsugu Muratsu
AMAkihiro Maruo
Akihiro Maruo
BACKGROUND Brodie's abscess is a rare form of subacute osteomyelitis that primarily affects the metaphyseal regions of long bones. Conventional treatment involves thorough curettage and systemic antibiotic therapy for ≥6 weeks, with bone grafting required for abscess sizes >3 cm. Continuous local antibiotic perfusion (CLAP) delivers high concentrations of antibiotics directly to the infection site and facilitates preservation of biologically active bone tissue. Here, we report a case of an extensive Brodie's abscess that was successfully treated with CLAP, highlighting its potential as an alternative to conventional treatment. CASE REPORT A 14-year-old boy was diagnosed with a 15-cm Brodie's abscess in the medial cortical bone of the left femur, with a primary infection in the intracortical pseudocavity. The patient underwent treatment with CLAP and intramedullary antibiotic perfusion pins were placed in the pseudocavity. Given the preservation of bone bioactivity, we anticipated spontaneous bone remodeling after infection control and therefore decided against bone grafting. The infection site received direct gentamicin infusions for 18 days, and systemic antibiotic therapy continued for 1 month. Postoperatively, the signs of inflammation rapidly subsided, and thereafter, no recurrence of infection was observed, while bone remodeling was achieved at the site of the bone defect. CONCLUSIONS In cases of cortical bone abscess, systemically administered antibiotics have limited penetration, whereas CLAP allows direct administration of high-concentration antibiotics to the lesion, which may provide an advantage in infection control. The findings of this case suggest that CLAP may serve as a viable treatment option for Brodie's abscess, particularly in cases with limited systemic antibiotic penetration.

14 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KOKeisuke Oe
Keisuke Oe
FZFeibi Zeng
Feibi Zeng
Takahiro NiikuraTakahiro Niikura
Takahiro Niikura
TFTomoaki Fukui
Tomoaki Fukui
KSKenichi Sawauchi
Kenichi Sawauchi
RKRyosuke Kuroda
Ryosuke Kuroda
When visualizing biological activity at nonunion sites by the radioisotopes, gamma rays are more attenuated if metal implants are placed in the bone. However, the effects of various implant types and their placement on gamma ray attenuation in quantitative evaluation remain unknown. To elucidate these effects, we created a phantom that simulated the nonunion of the femur in this study. The count of gamma rays was measured by single-photon emission computed tomography/computed tomography (SPECT/CT) while considering CT-based attenuation correction (CTAC), metal implant placement, type (intramedullary nail or plate), and position. The count differed significantly with and without CTAC and with and without implants (both types) under CTAC. Significantly different counts were observed between the intramedullary nail and plate placed contralaterally to the lesion (i.e., non-lesion side). No significant difference was observed between the intramedullary nail and plate on the lesion side or between plates on the non-lesion and lesion sides. The measured standardized uptake value (SUV) was closer to the true SUV with CTAC than without. Moreover, the count was higher with implants than without. However, even with implants, it was lower than the actual count, indicating the absence of overcorrection. Implant type and position do not seem to influence the count.