Oluwaseun Nneka Oni-Adimabua

Oluwaseun Nneka Oni-Adimabua

Auto-generated profile, based on publicly available information

Oluwaseun Nneka Oni-Adimabua

Ajayi Crowther University, Oyo, Oyo State, Nigeria

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2024 in European Journal of Sustainable Development Research
Verified
Journal Article
Open access
PDF file
OOOluwaseun Nneka Oni-Adimabua
Oluwaseun Nneka Oni-Adimabua
FIFavour Okechi Ifeanyi-Nze
Favour Okechi Ifeanyi-Nze
AAAyomide Khadijat Abimbolu
Ayomide Khadijat Abimbolu
EOEmmanuel Oluwakorede Opadokun
Emmanuel Oluwakorede Opadokun
AOAyodeji Reynolds Omolusi
Ayodeji Reynolds Omolusi
NANana Okai Ankomah
Nana Okai Ankomah
The search for environmentally friendly alternatives to conventional fossil fuels has been intensified by the global shift toward sustainable energy sources. With over 95% of the fuel market dominated by petroleum-based products, concerns regarding their limited biodegradability and high eco-toxicity have been escalated. In response, there is a growing demand for biobased solutions that can mitigate pollution and reduce greenhouse gas emissions. In this study, the synthesis of biodiesel from waste almond seed oil (WCO) was focused on, utilizing an innovative bifunctional catalyst derived from waste animal bones and almond shells. The efficacy of the catalyst synthesized from these unconventional materials was confirmed through rigorous characterization techniques, including scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray fluorescence (XRF), Fourier transform infrared (FTIR) spectroscopy, and Brunauer, Emmett, and Teller (BET) analysis. The physicochemical properties of WCO and the resulting biodiesel were evaluated according to ASTM D6751 and EN 14214 standards. To optimize the catalytic process, Box Behnken Design (BBD) was employed to explore the effects of key parameters: reaction temperature (40-60°C), reaction time (60-90 minutes), catalyst loading (0.5-1.5 wt%), and methanol-to-oil ratio (6:1-18:1). Remarkably, under optimal conditions, an impressive biodiesel yield of 86.2% was achieved. Specifically, the optimal parameters were a Methanol:Oil Ratio of 6.026, Catalyst Loading of 1.49917 wt%, Reaction Time of 66.8179 minutes, and Temperature of 59.9806°C. The potential of utilizing waste materials for sustainable biodiesel production is underscored by our findings. The bifunctional catalyst developed in this study represents a cost-effective and environmentally friendly alternative to conventional catalysts, contributing to cleaner fuel production methods.

23 April 2025 in European Journal of Sustainable Development Research
Verified
Journal Article
Open access
PDF file
EUEsther Udoh
Esther Udoh
LELeo Princewill Egba
Leo Princewill Egba
OOOluwaseun Nneka Oni-Adimabua
Oluwaseun Nneka Oni-Adimabua
UZUdochukwuka Confidenc Zogini
Udochukwuka Confidenc Zogini
SASaifullahi Abdullahi
Saifullahi Abdullahi
CIChukwudi Moses Ihezie
Chukwudi Moses Ihezie
This study aimed to evaluate the effectiveness of hybrid electrocoagulation (EC) and electrooxidation (EO) processes in treating effluent water from the industrial process plant in Owerri. The research involved assessing the physicochemical properties of the wastewater against the discharge standards set by the National Environmental Standards and Regulations Enforcement Agency. The treatment process used iron electrodes for both EC and EO, with optimal treatment times determined as 20 minutes for EC and 30 minutes for EO. Current densities ranging from 4.75 to 12.36 mA/cm² were tested. Key findings indicated that through EC, lead was completely removed, and copper and nickel concentrations were significantly reduced. EO further decreased turbidity and total dissolved solids (TDS) levels. The hybrid EC-EO process achieved a reduction in turbidity to acceptable discharge limits and significantly lowered TDS levels. However, a notable increase in chemical oxygen demand was observed during the hybrid treatment (up to 1099.87%), potentially due to operational issues such as electrode deposition and inadequate mixing. The limitations of the study included operational challenges such as equipment malfunction and human error, which affected the consistency of results. Future research should aim at optimizing process parameters, exploring alternative electrode materials, and addressing operational challenges to improve the efficiency and consistency of the EC-EO hybrid treatment method.

10 April 2026 in Smart Wearable Technology
Verified
Journal Article
Open access
PDF file
BOBoluwatife Oluwasegun
Boluwatife Oluwasegun
OOOluwaseun Oni-Adimabua
Oluwaseun Oni-Adimabua
KOKyrian Odo
Kyrian Odo
OAOpeyemi Samson Akanbi
Opeyemi Samson Akanbi
AEAimanose Eigbedion
Aimanose Eigbedion
HOHakeem Oyeshola
Hakeem Oyeshola
Wearable and stretchable strain sensors are central to smart wearable technology, enabling continuous, real-time, and noninvasive tracking of human motion and physiological signals for healthcare, sports, and human–machine interaction. Rapid progress in soft materials, structural design, and flexible electronics has led to devices with improved sensitivity, large strain range, durability, and skin conformability, yet practical translation into robust products remains limited. This review provides a comprehensive overview of recent advances in wearable and stretchable strain sensors with emphasis on healthcare applications. We first summarize key sensing mechanisms—including piezoresistive, capacitive, piezoelectric, triboelectric, and optical modes—and compare their operating principles and performance trade-offs. We then discuss material platforms such as elastomeric substrates, conductive polymers, nanomaterials, and hybrid composites, followed by critical design parameters (gauge factor, stretchability, hysteresis, response time, durability) that govern device performance. Structural and device engineering strategies, including microstructured surfaces, percolated networks, serpentine interconnects, porous scaffolds, and liquid-metal architectures, are highlighted as routes to achieving high performance under complex deformations. Representative applications in vital-sign monitoring, motion and gait analysis, rehabilitation, wound care, and smart textiles are reviewed, along with broader uses in soft robotics and structural health monitoring. Finally, we identify key challenges—long-term stability on skin, biocompatibility, power autonomy, secure data handling, standardized benchmarking, and scalable manufacturing—and outline future directions in self-powered systems, multimodal sensing, and AI-assisted analytics. This review aims to provide a consolidated framework to guide the design of next-generation, clinically relevant wearable strain-sensing platforms. Received: 2 December 2025 | Revised: 2 February 2026 | Accepted: 24 March 2026 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement Data sharing is not applicable to this article as no new data were created or analyzed in this study. Author Contribution Statement Boluwatife Oluwasegun: Formal analysis, Investigation, Writing – original draft, Visualization. Oluwaseun Oni-Adimabua: Conceptualization, Writing – original draft. Kyrian Odo: Conceptualization, Methodology. Opeyemi Akanbi: Conceptualization, Writing – review & editing, Supervision, Project administration. Aimanose Eigbedion: Methodology, Formal analysis. Joseph Igbama: Validation, Investigation. Joseph Alieme: Validation, Investigation. Folakemi Ijagbemi: Validation, Resources. Ayotunde Igbekele: Resources, Visualization. Michael Adelere: Supervision, Project administration. Hakeem Oyeshola: Formal analysis, Writing – review & editing.