Valéria Romero

Valéria Romero

Auto-generated profile, based on publicly available information

Valéria Romero

Universidade Estadual de Campinas, Brazil

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
HDHelton L. A. Defino
Helton L. A. Defino
HCHerton R. T. Costa
Herton R. T. Costa
ANAltacilio Aparecido Nunes
Altacilio Aparecido Nunes
MNMarcello Nogueira-Barbosa
Marcello Nogueira-Barbosa
VRValéria Romero
Valéria Romero
Thoracolumbar fractures are most frequent along the spine, and surgical treatment is indicated for unstable fractures. Percutaneous minimally invasive surgery was introduced to reduce the pain associated with the open posterior approach and reduce the morbidity of the procedure by avoiding damage and dissection of the paravertebral muscles. The goal of this study is to compare the surgical treatment of fractures of the thoracolumbar spine treated by the conventional open approach and the percutaneous minimally invasive approach using similar types of pedicle spine fixation systems. This study is designed as a multi-center, randomized controlled trial of patients aged 18–65 years who are scheduled to undergo surgical posterior fixation. Treatment by the conventional open approach or percutaneous minimally invasive approach will be randomly assigned. The primary outcome measure is postoperative pain, which will be measured using the visual analogue scale (VAS). The secondary outcome parameters are intraoperative bleeding, postoperative drainage, surgery time, length of hospital stay, SF-36, EQ-5D-5 l, HADS, pain medication, deambulation after surgery, intraoperative fluoroscopy time, vertebral segment kyphosis, fracture vertebral body height, compression of the vertebral canal, accuracy of the pedicle screws, and breakage or release of the implants. Patient will be followed up for 1, 2, 3, 6, 12 and 24 months postoperatively and evaluated according to the outcomes using clinical and radiological examinations, plain radiographs and computed tomografy (CT). Surgical treatment of thoracolumbar fractures by the open or percutaneous minimally invasive approach will be compared in a multicenter randomized study using similar types of fixation systems, and the results will be evaluated according to clinical and radiological parameters at 1, 2, 3, 6, 12 and 24 months of follow-up. ClinicalTrial.gov approval number: 1.933.631, code: NCT03316703 in may 2017.

16 October 2018 in Current Medicinal Chemistry
Verified
Journal Article
Closed access
PDF file
ARAna Claudia Pompeu Raminelli
Ana Claudia Pompeu Raminelli
VRValeria Romero
Valeria Romero
MSMohammad H. Semreen
Mohammad H. Semreen
GLGislaine Ricci Leonardi
Gislaine Ricci Leonardi
Background: The clinical efficacy of the topical tretinoin is widely studied and has been well established for many therapeutic interventions, among some, photoaging, acne, and melasma. However, the side effects, mainly cutaneous irritation, erythema, xerosis and peeling, remain major obstacle to the patient compliance. Besides, the insight regarding the drug delivery profile is essential to understand the therapeutic action of the drug. Methods: Through bibliographic research in databases we highlight further advances and an update on tretinoin delivery systems such as liposomes, niosomes, solid lipid nanoparticles, nanostructured lipid carriers, cyclodextrins, nanostructured polymers and other technological systems that reduce its side effects and improve the permeation profile to potentiate efficacy and drug safety on the skin. Results: Pharmaceutical preparations were developed and evaluated for permeability in in vitro models using pig ear, snake, mouse and human skin, and potential for irritation was also verified using release systems for tretinoin and compared to available commercial formulations. Overall results indicated the composition, charge and size of the system influences the tretinoin delivery, modulating the type of release and its retention. Small unilamellar vesicles promoted greater cutaneous delivery of tretinoin. Negative charge, for both liposomes and niosomes, can improve pig skin hydration as well as the tretinoin retention. The quantity of solid lipids and the type of oil used in the composition of solid lipid nanoparticles and nanostructured lipid carriers affected percutaneous drug delivery. Conclusion: As evident from the literature, the tretinoin technological delivery systems consist an innovative and potential management for increasing the patient compliance presenting safety and efficacy.

1 September 2019 in Brazilian Journal of Anesthesiology (English Edition)
Verified
Journal Article
Open access
VRValéria Romero
Valéria Romero
JLJuliana Rodrigues Lara
Juliana Rodrigues Lara
Francisco Otero-EspinarFrancisco Otero-Espinar
Francisco Otero-Espinar
MSManoel Henrique Salgado
Manoel Henrique Salgado
NMNorma Sueli Pinheiro Modolo
Norma Sueli Pinheiro Modolo
GBGuilherme Antonio Moreira de Barros
Guilherme Antonio Moreira de Barros
Myofascial pain syndrome is a common cause of musculoskeletal pain. The objective of this study was to evaluate the potential analgesic action of 8% capsaicin cream for topical use in patients with myofascial pain syndrome. Initially, cream formulations of PLA (Placebo) and CPS (Capsaicin 8%) were developed and approved according to the current requirements of the health authority agency. The 40 participating patients were randomly assigned to the PLA and CPS groups in a double-blind fashion. Before the creams were topically administered, according to the allocation group, the local anesthetic was used for a period of 50 minutes directly in the area of interest. The cream was applied to the area of the skin over the trigger point, represented by the area with pain at palpation, in an amount of 10 g for 30 minutes in a circular area of 24 mm diameter. Subsequently, the cream was removed and the skin tolerability parameters were evaluated. The pain was measured before and during the formulation application, as well as at 1 hour, 7 days, 30 days, and 60 days after the procedure, evaluated using a verbal numerical scale (from 0 to 10: with 0 = no pain and 10 = worst pain imaginable). No patient in PLA Group had hyperemia or burning sensation at the site of application, while 85% of patients in CPS Group had hyperemia or burning sensation at 15 minutes. These complaints disappeared 24 hours after the cream was removed. The pain score in CPS Group decreased steadily up to the 60th day of evaluation (p < 0.0001). Application of the formulations did not cause macroscopic acute or chronic skin lesions in patients, and the 8% capsaicin formulation was beneficial and well tolerated.

1 April 2020 in Acta Ortopedica Brasileira
Verified
Journal Article
Open access
PDF file
TMThiago Dantas Matos
Thiago Dantas Matos
RFRodrigo Barra Caiado Fleury
Rodrigo Barra Caiado Fleury
KTKelsen DE Oliveira Teixeira
Kelsen DE Oliveira Teixeira
VRValéria Romero
Valéria Romero
HDHelton Luiz Aparecido Defino
Helton Luiz Aparecido Defino
Objective: To evaluate the morphological changes on the intervertebral foramen and segmental lordosis related to the transforaminal lumbar interbody fusion (TLIF) positioning. Methods: PEEK cages were placed in the disc space (L1-S1) of a polyurethane anatomical model. Cages of different heights (8 mm, 10 mm, 12 mm and 14 mm) were positioned in the posterior, medial or anterior part of the vertebral body surface, and the intervertebral foramen and segmental lordosis heights were measured after their insertion. Results: The vertebral foramen height decreased in all positions and heights of the cages in relation to the control. The cage posterior positioning induced a smaller reduction in the vertebral foramen height. Vertebral lordosis tended to increase in relation to the control, and the greatest increase occurred with the cage posterior positioning. Conclusion: Cage positioning induces changes in the intervertebral foramen height and in the vertebral segment lordosis. Cage posterior positioning induces a smaller reduction of the intervertebral foramen height and increases the vertebral segment lordosis. Level of evidence III, Therapeutic study.

1 January 2018 in Surgical & Cosmetic Dermatology
Verified
Journal Article
Open access
VRValéria Romero
Valéria Romero
EKEmiro Khury
Emiro Khury
LALaura Moretti Aiello
Laura Moretti Aiello
MFMary Ann Foglio
Mary Ann Foglio
GLGislaine Ricci Leonardi
Gislaine Ricci Leonardi
Revista Online - Surgical & Cosmetic Dermatology | Publicação oficial da Sociedade Brasileira de Dermatologia, a segunda maior sociedade dermatológica do mundo com mais de 5.000 associados, o periódico Surgical & Cosmetic Dermatology, editada em 2009, constitui publicação médica destinada a difundir a experiência brasileira nas áreas de Cirurgia Dermatológica e Cosmiatria. É uma publicação trimestral das Sociedades Brasileiras de Dermatologia e de Cirurgia Dermatológica.

8 June 2020 in Revista Brasileira de Ortopedia
Verified
Journal Article
Open access
PDF file
RFRodrigo Barra Caiado Fleury
Rodrigo Barra Caiado Fleury
ASAntônio Carlos Shimano
Antônio Carlos Shimano
TMThiago Dantas Matos
Thiago Dantas Matos
KTKelsen de Oliveira Teixeira
Kelsen de Oliveira Teixeira
VRValéria Romero
Valéria Romero
HDHelton Luiz Aparecido Defino
Helton Luiz Aparecido Defino
Objetivo Comparar por testes mecânicos a resistência ao arrancamento e o torque de inserção do parafuso pedicularjateado e liso. Métodos Parafusos pediculares de superfície áspera e de superfície lisa com diâmetros de 4,8; 5,5 e 6,5 mm foram inseridos em blocos de poliuretano com densidade de 10 PCF (0,16 g/cm3). O torque de inserção e a força de arrancamento foram avaliados. Resultados A força de arrancamento dos parafusos de superfície áspera e de superfície lisa não diferiu, exceto no grupo de parafusos com 4,8 mm de diâmetro. Nesse grupo, os parafusos de superfície áspera apresentaram maior resistência ao arrancamento. Conclusão Os parafusos pediculares de superfície áspera não apresentaram aumento da resistência ao arrancamento na fase aguda de sua inserção em blocos de poliuretano em relação aos parafusos de superfície lisa. Os parafusos de superfície áspera apresentaram maior torque de inserção que os parafusos de superfície lisa, dependendo do diâmetro do parafuso e da preparação do furo piloto. Cada autor contribuiu individual e significativamente para o desenvolvimento deste artigo. Fleury R. B. C.(0000–0001–7643–6466) *: Contribuições substanciais para a concepção e desenho do trabalho, aquisição e interpretação de dados para o trabalho e aprovação final da versão a ser publicada; Shimano A. C.(0000–0002–3119–2362) *: contribuição para a coleta, análise e aprovação final dos dados; Matos T. D. (0000–0003–3853–502X) *: contribuição para a coleta e análise de dados; Teixeira K. O. (0000–0002–8165–2427) *: contribuição para a coleta e análise de dados; Romero V. (0000–0002–3278–5223) *: revisão para conteúdo intelectual importante; Defino H. L. A. (0000–0003–4274–0130) *: Contribuições substanciais para a concepção e desenho do trabalho, contribuições para a análise e interpretação dos dados para o trabalho e aprovação final da versão a ser publicada. ∗ Trabalho desenvolvido no Departamento de Biomecânica, Medicina e Reabilitação do Aparelho Locomotor, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brasil.