Aberration-corrected high-resolution transmission electron microscopy (HRTEM) is used to measure strain in a strained-silicon metal-oxide-semiconductor field-effect transistor. Strain components parallel and perpendicular to the gate are determined directly from the HRTEM image by geometric phase analysis. source and drain stressors lead to uniaxial compressive strain in the Si channel, reaching a maximum value of just below the gate oxide, equivalent to 2.2 GPa. Strain maps obtained by linear elasticity theory, modeled with the finite-element method, agree with the experimental results to within 0.1%.
1 July 2011 in Ultramicroscopy
11 October 2006 in Philosophical Magazine
Stresses and strains around a dislocation at a grain boundary in germanium are measured by a combination of high-resolution electron microscopy and geometric phase analysis. The method is established by first measuring the strains around a matrix dislocation in silicon. Stresses are determined using linear elastic theory and bulk elastic constants. Strain measurements are shown to agree with theoretical calculations based on linear anisotropic elastic theory to 0.2% at a spatial resolution of 2–3 nm. A dislocation constricted at a coherent twin boundary in germanium is subsequently analyzed. The method is adapted to cope with the problem that the reference lattice is not identical for the whole field of view, due to the grain boundary. Strains are compared with theoretical calculations of a matrix dislocation in germanium. Whereas strains in the grains on either side of the twin boundary agree closely with the isolated dislocation case, significant additional strains are localized at the boundary plane. By comparing the stresses and strains across the boundary plane, values for the elastic modulus of the twin boundary are proposed. The significant reduction in elastic modulus for the boundary, when compared to bulk elastic constants, is interpreted in terms of the non-equilibrium configuration of the boundary. An extension of the method is proposed to measure more generally the elastic properties of grain boundaries and interfaces.
1 June 2005 in Microscopy
The distortions introduced into high-resolution transmission electron microscope (HRTEM) images by the projector lens system are an important source of systematic error for quantitative displacement and strain determination. Using geometric phase analysis of images of perfect crystals, we measured these errors for two different transmission electron microscopes. Local magnification varies by as much as 5%, and rotation can reach 2° across a typical image. Our experimental results are compared with theory, and optical pincushion and spiral distortion coefficients are determined. A method for calibrating and removing these distortions is presented that enables quantification to 0.1% strain and 0.1° rotation across the whole field of view. This calibration is also critical for the accurate measurement of local lattice parameters from HRTEM images.
1 December 2006 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms