S. Rollet

S. Rollet

Auto-generated profile, based on publicly available information

S. Rollet

Austrian Institute of Technology, Donau-City-Straße 1, A-1220 Vienna, Austria

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2006 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
MLMarcin Latocha
Marcin Latocha
MAM. Autischer
M. Autischer
PBP. Beck
P. Beck
JBJ. F. Bottolier-Depois
J. F. Bottolier-Depois
SRS. Rollet
S. Rollet
FIFrançois IRSN
François IRSN
The European-Commission-supported project DOSMAX (Dosimetry of Aircrew Exposure to Radiation During Solar Maximum) was aimed at measuring aircrew exposure to cosmic radiation on-board the aircraft during solar maximum. During a dedicated international comparison mission (Co-ordinated Access to Aircraft for Transnational Environmental Research; CAATER) different measurement techniques have been compared by six European institutes (Results of the CAATER Mission, DOSMAX Meeting, Dublin, June 2004). In this paper, we present the tissue-equivalent proportional counter (TEPC) measurements carried out by ARC Seibersdorf research (ARCS), Austria, and Institut de Radioprotection et de Sûreté Nucléaire (IRSN), France, together with a comparison with simulation results under the same conditions. The whole flight campaign consists of four different in-flight investigations performed at two different geographical positions at 12.2 km (FL 400) and 9.8 km (FL 320). One location was chosen above Rome (42° North, 12° East), Italy, for high cut-off rigidity (6.4 GV) and the second above Aalborg (57° North, 10° East), Denmark, for low cut-off rigidity (1.8 GV). The TEPC measurements are presented in terms of absorbed dose and ambient dose equivalent as well as microdosimetric spectra as a function of lineal energy. For the same conditions of the CAATER flights the response of the TEPC has also been simulated by using the Monte Carlo Transport Code FLUKA (version 2003). The results from simulations are compared with measurements and they show a reasonable agreement.

1 August 2009 in Radiation Measurements
Verified
Journal Article
Closed access
SRS. Rollet
S. Rollet
SAS. Agosteo
S. Agosteo
GFG. Fehrenbacher
G. Fehrenbacher
CHC. Hranitzky
C. Hranitzky
TRT. Radon
T. Radon
MWM. Wind
M. Wind

16 December 2006 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
SRS. Rollet
S. Rollet
MAM. Autischer
M. Autischer
PBP. Beck
P. Beck
MLM. Latocha
M. Latocha
The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been studied. The measurements have been done at the CERN-EU High-Energy Reference Field (CERF) facility where a well-characterised radiation field is available for intercomparison. The TEPC instrument used by the ARC Seibersdorf Research is filled with pure propane gas at low pressure and can be used to determine the lineal energy distribution of the energy deposition in a mass of gas equivalent to a 2 μm diameter volume of unit density tissue, of similar size to the nuclei of biological cells. The linearity of the detector response was checked both in term of dose and dose rate. The effect of dead-time has been corrected. The influence of the detector exposure location and orientation in the radiation field on the dose distribution was also studied as a function of the total dose. The microdosimetric distribution of the absorbed dose as a function of the lineal energy has been obtained and compared with the same distribution simulated with the FLUKA Monte Carlo transport code. The dose equivalent was calculated by folding this distribution with the quality factor as a function of linear energy transfer. The comparison between the measured and simulated distributions show that they are in good agreement. As a result of this study the detector is well characterised, thanks also to the numerical simulations the instrument response is well understood, and it's currently being used onboard the aircrafts to evaluate the dose to aircraft crew caused by cosmic radiation.

31 December 2010 in Radiation Measurements
Verified
Journal Article
Closed access
MLM. Luszik-Bhadra
M. Luszik-Bhadra
PBP. Beck
P. Beck
TBThomas Berger
Thomas Berger
AJA. Jaksic
A. Jaksic
MLM. Latocha
M. Latocha
GRG. Reitz
G. Reitz