Reddipalli Bhargav

Reddipalli Bhargav

Auto-generated profile, based on publicly available information

Reddipalli Bhargav

Indian Institute of Technology Roorkee, Roorkee, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
RBReddipalli Bhargav
Reddipalli Bhargav
BBBhavesh R. Bhalja
Bhavesh R. Bhalja
CGChandra. P. Gupta
Chandra. P. Gupta
Accurate estimation of fault location is highly crucial for swift maintenance and early power restoration. Since faults in DC networks are time critical, this paper proposes a new fault detection and localization scheme for a low voltage direct current (LVDC) micro-grid network. Low resistance faults are detected by observing voltage across the inductor whereas high resistance ground faults are identified by measuring ground current at the relay location. Thereafter, based on iterative method, fault location is estimated by comparing analytically derived fault current with the measured value of fault current. Genuineness of the suggested technique has been assessed by simulating various internal, external and simultaneous faults on a typical LVDC micro-grid network modeled in PSCAD/EMTDC environment. The proposed method is capable of detecting and locating both low and high resistance DC faults without utilizing remote end quantities. Subsequently, initial guess has minimal impact on the convergence and accuracy of the proposed algorithm. Comparative evaluation of the proposed technique with other techniques clearly proves its superiority in terms of better discrimination against external faults, rapid detection during internal faults, independency on the network topology and higher accuracy for fault distance estimation against all types of internal faults.

22 November 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
RBReddipalli Bhargav
Reddipalli Bhargav
CGChandra P. Gupta
Chandra P. Gupta
BBBhavesh R. Bhalja
Bhavesh R. Bhalja
Even though the implementation of hybrid AC/DC microgrid is increasing, their protection schemes face multiple challenges such as inconsistent fault current supply from DGs, difficulty in discriminating internal/ external faults and missing of universal protection scheme for both AC and DC distribution networks. In this regard, a unified fault detection and localization scheme is proposed for hybrid AC/DC microgrid. By measuring the impedance at system frequency for AC circuit and at a specific pre-inserted frequency for DC network, the suggested technique achieves proper discrimination between internal faults and external events. Several fault scenarios such as internal/external faults, single/double line faults with varying fault location and fault resistance have been investigated on both AC and DC circuits by modeling hybrid AC/DC microgrid in PSCAD/EMTDC environment. The results reveal the effectiveness of the proposed algorithm in discriminating internal faults with external events and also in estimating accurate fault location even under noisy environment. Finally, a comparative evaluation of the proposed unified AC/DC protection scheme with other individual AC/DC protection schemes shows its superiority in combining both the AC and DC schemes together into a single relay, having an improved fault detection time and an increased fault localization accuracy.

15 July 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
RBReddipalli Bhargav
Reddipalli Bhargav
BBBhavesh R. Bhalja
Bhavesh R. Bhalja
CGChandra Prakash Gupta
Chandra Prakash Gupta
This study proposes a new method to detect and locate the fault in a DC distribution system in the presence of distributed generators. As the mesh‐type network provides good continuity of service during faults and the bipolar system transmits high power at low‐voltage level to the end user, the proposed scheme has utilised 1200 V mesh‐type bipolar DC microgrid network. The proposed scheme detects a fault by comparing the calculated value of fault current and pole‐to‐pole voltage with the pre‐defined threshold values and then distinguishes internal or external fault based on an estimation of line parameters. In case of an internal fault, the estimated parameters yield the exact location of the fault. The modelling of the aforementioned DC microgrid network has been carried out in PSCAD/EMTDC environment and various faults involving pole and ground have been performed with variable fault resistance and location. The simulation results clearly indicate that the proposed technique is not only capable to detect the fault rapidly but also able to disconnect the faulty section speedily (around 1.25 ms). As the proposed method detects fault by utilising local voltages and currents, its reliability is better than the previous algorithms.