Maria O. Romanenko

Maria O. Romanenko

Auto-generated profile, based on publicly available information

Maria O. Romanenko

Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department (Moscow Center for Diagnostics and Telemedicine)

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2024 in Healthcare
Verified
Journal Article
Open access
PDF file
YVYuriy Vasilev
Yuriy Vasilev
AVAnton Vladzymyrskyy
Anton Vladzymyrskyy
YAYulya A. Alymova
Yulya A. Alymova
DADina Akhmedzyanova
Dina Akhmedzyanova
Ivan BlokhinIvan Blokhin
Ivan Blokhin
RRRoman V. Reshetnikov
Roman V. Reshetnikov
Introduction: Artificial Intelligence (AI) is becoming an essential part of modern radiology. However, available evidence highlights issues in the real-world applicability of AI tools and mixed radiologists’ acceptance. We aimed to develop and validate a questionnaire to evaluate the attitude of radiologists toward radiology AI (ATRAI-14). Materials and Methods: We generated items based on the European Society of Radiology questionnaire. Item reduction yielded 23 items, 12 of which contribute to scoring. The items were allocated into four domains (“Familiarity”, “Trust”, “Implementation Perspective”, and “Hopes and Fears”) and a part related to the respondent’s demographics and professional background. As a pre-test method, we conducted cognitive interviews with 20 radiologists. Pilot testing with reliability and validity assessment was carried out on a representative sample of 90 respondents. Construct validity was assessed via confirmatory factor analysis (CFA). Results: CFA confirmed the feasibility of four domains structure. ATRAI-14 demonstrated acceptable internal consistency (Cronbach’s Alpha 0.78 95%CI [0.68, 0.83]), good test–retest reliability (ICC = 0.89, 95% CI [0.67, 0.96], p-value < 0.05), and acceptable criterion validity (Spearman’s rho 0.73, p-value < 0.001). Conclusions: The questionnaire is useful for providing detailed AI acceptance measurements for making management decisions when implementing AI in radiology.

25 August 2025 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
MRMaria O. Romanenko
Maria O. Romanenko
MKMaria R. Kodenko
Maria R. Kodenko
PGPavel Gelezhe
Pavel Gelezhe
Ivan BlokhinIvan Blokhin
Ivan Blokhin
RRRoman V. Reshetnikov
Roman V. Reshetnikov
ВАВасильев Юрий Александрович
Васильев Юрий Александрович
BACKGROUND: Texture analysis improves the diagnostic accuracy of magnetic resonance imaging and differential diagnosis of prostate lesions, which are primarily segmented through manual labeling, resulting in significant inter-expert variability of masks. A consensus-based technique can help reduce inconsistencies in prostate lesion segmentation. However, global scientific studies have not described any standardized, consensus-based labeling protocols. AIM: This study aimed to develop a consensus algorithm for manual labeling of prostate lesions by several independent experts and evaluate inter-expert consistency in lesion segmentation. METHODS: This retrospective study included 60 biparametric magnetic resonance imaging scans of the prostate gland performed according to PI-RADS 2.1 technical specification. The scans showed PI-RADS 3, 4, and 5 lesions. Two independent radiologists manually segmented the prostate lesions using 3D Slicer. Then, the resulting masks were compared using the Dice–Sørensen coefficient (DSC). For lesions with DSC ≥ 0.75, the final mask was based on the overlap between the two original masks. Conversely, for lesions with DSC 0.75, the final mask was determined using the proposed consensus algorithm. RESULTS: The proposed consensus algorithm significantly increased the DSC values, from 0.61 [0.48; 0.73] for primary labeling to 0.74 [0.62; 0.79] for labeling using the proposed algorithm (p = 0.01). CONCLUSION: The proposed consensus-based algorithm for labeling prostate lesions using magnetic resonance imaging data is crucial in addressing inadequate approaches to objective segmentation in research and clinical settings.

5 April 2026 in Siberian Journal of Clinical and Experimental Medicine
Verified
Journal Article
Closed access
YVYuriy Vasilev
Yuriy Vasilev
Anastasia KarpenkoAnastasia Karpenko
Anastasia Karpenko
MRM. O. Romanenko
M. O. Romanenko
OOOlga Omelyanskaya
Olga Omelyanskaya
AVAnton Vladzymyrskyy
Anton Vladzymyrskyy
Ivan BlokhinIvan Blokhin
Ivan Blokhin
Background . Preoperative differentional diagnosis of meningioma grade remains challenging with routine brain magnetic resonance imaging (MRI). The lack of reliable non-invasive tools limits the potential for early risk stratification and treatment planning. Aim : To develop an interpretable classification radiomic model RadMenGR for predicting meningioma grade (Grade I or Grade II) based on contrast-enhanced T1-weighted images. Material and Methods . This retrospective single-center study was conducted using the open-source anonymized dataset MeningiomaSEG-CLASS. 95 patients were included in the analysis (53 with Grade 1 and 42 with Grade 2 tumors). 105 radiomic features were extracted from manually segmented MR images using PyRadiomics. Classification was performed with a Naive Bayes algorithm following feature discretization using the Entropy / MDL method. Diagnostic performance was assessed using the area under the curve (AUC), sensitivity, specificity, and accuracy. Bootstrap analysis with 10,000 iterations and a 95% confidence interval was used for validation. Results . On the validation cohort (n = 46), the ROC-AUC was 0.805 (95% CI: 0.671–0.915). The lower bound of the 95% CI for the AUC exceeded the value under the null hypothesis (AUC = 0.63), confirming the statistical significance of the results (p < 0.05). Conclusion. This study developed an interpretable radiomic classification model for the differential diagnosis of Grade 1 and Grade 2 meningiomas. The application of a Naive Bayes algorithm to features extracted from contrast-enhanced T1-weighted images and transformed using a discretization method enabled the achievement of a significant level of diagnostic accuracy. However, the width of the confidence interval points to a lack of model robustness, necessitating validation on an independent cohort.