This dataset contains anonymised human lung computed tomography (CT) scans with COVID-19 related findings, as well as without such findings. A small subset of studies has been annotated with binary pixel masks depicting regions of interests (ground-glass opacifications and consolidations). CT scans were obtained between 1st of March, 2020 and 25th of April, 2020, and provided by municipal hospitals in Moscow, Russia. Permanent link: https://mosmed.ai/datasets/covid19_1110 . This dataset is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported (CC BY-NC-ND 3.0) License.
With the ongoing COVID-19 pandemic decreasing availability of polymerase chain reaction with reverse transcription and the snowballing growth of medical imaging, especially the number of chest computed tomography (CT) scans being performed, methods to augment and automate the image analysis, increasing productivity and minimizing human error are of particular importance. The creation of high-quality datasets is essential for the development and validation of artificial intelligence algorithms. Such technologies have sufficient accuracy in diagnosing COVID-19 in medical imaging. The presented large-scale dataset contains anonymized human CT scans with COVID-19 features as well as normal studies. Some studies were tagged by radiologists using binary pixel masks of regions of interest (e.g., characteristic areas of consolidation and ground-glass opacities). CT data were acquired between March 1, 2020, and April 25, 2020, and provided by municipal hospitals in Moscow, Russia. The presented dataset is licensed under Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported (CC BY-NC-ND 3.0).
Mammography is still the only screening method for breast cancer. Although digital mammography is the most common and widely used method for detecting breast cancer, it is ineffective at detecting and assessing intratumoral heterogeneity. Due to the small size of the tissue sample or tumor, biopsies often fail to represent the entire tumor. For this reason, selecting a treatment and determining a patients prognosis becomes difficult. In this case, medical imaging is a noninvasive approach that can provide a more comprehensive view of the entire tumor, act as a virtual biopsy, and be useful for monitoring disease progression and response to therapy. Radiomics with texture analysis allows you to look at an image as a group of numerical data, moving beyond the usual visual perception and into a deeper analysis of digital, pixel data to improve the accuracy of differential diagnosis. Radiogenomics is a natural extension of radiomics that focuses on determining gene expression based on radiologic tumor phenotype. The purpose of this review is to evaluate the role of mammography in breast cancer radiomics and radiogenomics. The article presents a literature review of relevant Russian scientific articles found in databases such as PubMed, Medline, Springer, eLibrary, and Google Scholar. The information obtained was then pooled, structured, and analyzed to examine the role of mammography in breast cancer screening radiomics.
Diagnostic and treatment approaches in prostate cancer rely on a combination of magnetic resonance imaging and histological data. This study aimed to introduce the basics of the current diagnostic approach in prostate cancer with a focus on texture analysis. Texture analysis evaluates the relationships between image pixels using mathematical methods, which provide additional information. First-order texture analysis of features can have greater clinical reproducibility than higher-order texture features. Textural features that are extracted from diffusion coefficient maps have shown the greatest clinical relevance. Future research should focus on integrating machine learning methods to facilitate the use of texture analysis in clinical practice. The development of automated segmentation methods is required to reduce the likelihood of including normal tissue in the area of interest. Texture analysis allows the noninvasive separation of patients into groups in terms of possible treatment options. Currently, few clinical studies reported on the differential diagnosis of clinically significant prostate cancer, including the Gleason and International Society of Urological Pathology grading. Large prospective studies are required to verify the diagnostic potential of textural features.
Objective: to assess the diagnostic accuracy of services based on computer vision technologies at the integration and operation stages in Moscow’s Unified Radiological Information Service (URIS). Methods: this is a multicenter diagnostic study of artificial intelligence (AI) services with retrospective and prospective stages. The minimum acceptable criteria levels for the index test were established, justifying the intended clinical application of the investigated index test. The Experiment was based on the infrastructure of the URIS and United Medical Information and Analytical System (UMIAS) of Moscow. Basic functional and diagnostic requirements for the artificial intelligence services and methods for monitoring technological and diagnostic quality were developed. Diagnostic accuracy metrics were calculated and compared. Results: based on the results of the retrospective study, we can conclude that AI services have good result reproducibility on local test sets. The highest and at the same time most balanced metrics were obtained for AI services processing CT scans. All AI services demonstrated a pronounced decrease in diagnostic accuracy in the prospective study. The results indicated a need for further refinement of AI services with additional training on the Moscow population datasets. Conclusions: the diagnostic accuracy and reproducibility of AI services on the reference data are sufficient, however, they are insufficient on the data in routine clinical practice. The AI services that participated in the experiment require a technological improvement, additional training on Moscow population datasets, technical and clinical trials to get a status of a medical device.
Computed tomography (CT) has been an essential diagnostic tool during the COVID-19 pandemic. The study aimed to develop an optimal CT protocol in terms of safety and reliability. For this, we assessed the inter-observer agreement between CT and low-dose CT (LDCT) with soft and sharp kernels using a semi-quantitative severity scale in a prospective study (Moscow, Russia). Two consecutive scans with CT and LDCT were performed in a single visit. Reading was performed by ten radiologists with 3–25 years’ experience. The study included 230 patients, and statistical analysis showed LDCT with a sharp kernel as the most reliable protocol (percentage agreement 74.35 ± 43.77%), but its advantage was marginal. There was no significant correlation between radiologists’ experience and average percentage agreement for all four evaluated protocols. Regarding the radiation exposure, CTDIvol was 3.6 ± 0.64 times lower for LDCT. In conclusion, CT and LDCT with soft and sharp reconstructions are equally reliable for COVID-19 reporting using the “CT 0-4” scale. The LDCT protocol allows for a significant decrease in radiation exposure but may be restricted by body mass index.