Adrien Kiss

Adrien Kiss

Auto-generated profile, based on publicly available information

Adrien Kiss

BIPM, Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312 Sèvres Cedex, France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Metrologia
Verified
Journal Article
Closed access
MSM Stock
M Stock
PCP Conceição
P Conceição
HFH Fang
H Fang
FBF Bielsa
F Bielsa
AKA Kiss
A Kiss
HAH Ahmedov
H Ahmedov
Main text: This report describes the second CCM key comparison of realizations of the kilogram definition based on the fixed numerical value of the Planck constant, which came into force on 20 May 2019. The objectives were to determine the level of agreement between realizations of the kilogram using Kibble and joule balances and the x-ray crystal density (XRCD) method and to provide input for the calculation of the second "consensus value" of the kilogram. The consensus value serves as the basis for an internationally coordinated dissemination of the kilogram and is updated after each new key comparison. Its use will continue until satisfactory agreement between realization experiments has been achieved. Another objective was the determination of the reproducibility of the realization experiments by comparing the new results with those of the first key comparison of kilogram realizations, CCM.M-K8.2019. The comparison was organized by the BIPM and had nine participants. The BIPM, LNE, METAS, NIST, NRC and UME operated Kibble balances, the NIM used a joule balance and the NMIJ and the PTB participated using 28Si spheres, the masses of which were determined with the XRCD method. These realization methods were used to calibrate 1 kg mass standards under vacuum or in air. The standards were sent to the BIPM where they were compared with each other and with BIPM Pt-Ir working standards. The latter were calibrated traceable to the International Prototype of the Kilogram (IPK), the mass of which served as the definition of the kilogram until 20 May 2019. The results of the weighings at the BIPM together with the measurement results communicated by the participants allowed comparison of the values attributed to 1 kg mass standards using the realization experiments of the participants. The level of agreement between mass determinations with the realization experiments and the BIPM as-maintained mass unit, traceable to the Planck constant through the mass of the International Prototype of the Kilogram, could also be deduced. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

30 December 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Shisong LiShisong Li
Shisong Li
FBFranck Bielsa
Franck Bielsa
MSMichael Stock
Michael Stock
AKAdrien Kiss
Adrien Kiss
HFHao Fang
Hao Fang
Yoke-based permanent magnetic circuits are widely used in Kibble balance experiments. In these magnetic systems, the coil current, with positive and negative signs in two steps of the weighing measurement, can cause an additional magnetic flux in the circuit and hence a magnetic field change at the coil position. The magnetic field change due to the coil current and related systematic effects have been studied with the assumption that the yoke material does not contain any magnetic hysteresis. In this paper, we present an explanation of the magnetic hysteresis error in Kibble balance measurements. An evaluation technique based on measuring yoke minor hysteresis loops is proposed to estimate the effect. The dependence of the magnetic hysteresis effect and some possible optimizations for suppressing this effect are discussed.

8 February 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FBF. Bielsa
F. Bielsa
HFH. Fang
H. Fang
AKA. Kiss
A. Kiss
MSM. Stock
M. Stock
The paper describes a new interferometric system for measuring the coil displacement in the BIPM Kibble balance. The system has led to a significant reduction in both the type A and type B uncertainty of the Kibble balance measurement. Compared to the previous version, the new instrument doubles the measurement signal thanks to a novel design. The optical and mechanical set-up is more compact, more stable and less sensitive to vibration noise. It is also more easily aligned, particularly for adjusting the interferometer beams vertically.