Ali Akbar Shah

Ali Akbar Shah

Auto-generated profile, based on publicly available information

Ali Akbar Shah

NCRA-CMS Lab, Mehran University of Engineering and Technology, Jamshoro, Sindh, Pakistan

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2023 in IEEE Access
Verified
Journal Article
Open access
MSMuhammad Zakir Shaikh
Muhammad Zakir Shaikh
ZAZeeshan Ahmed
Zeeshan Ahmed
BSBhawani Shankar
Bhawani Shankar
Enrique Nava BaroEnrique Nava Baro
Enrique Nava Baro
THTanweer Hussain
Tanweer Hussain
ASAli Akber Shah
Ali Akber Shah
In recent decades, there has been a constant demand for faster, longer, and safer railway networks. This also brings challenges for condition monitoring systems in modern railway vehicles. More specifically, critical parts of railway vehicles like wheels degrade over time due to various operational and environmental reasons. Different dynamic effects such as skidding/sliding over the track and the presence of contamination between wheel-rail cause various wheel defects. Faulty wheels ultimately lead to the derailment of railway vehicles. To avoid worst situations like railway derailments, various research has been conducted for developing efficient condition monitoring systems for railway wheels. In addition, there have been some commercial condition monitoring products that can be deployed with railway vehicles. These systems incorporate various sensors such as strain gauges and vision sensors to collect data for diagnosis and prognosis. Various methods have been explored but yet there is a broad research gap in terms of developing advanced onboard condition monitoring systems. With the progress in technology, advanced systems with Machine Learning/Deep Learning methods can provide more efficient and robust condition monitoring of dynamic railway systems. Considering the need for advancement in condition monitoring systems for railway vehicles, a comprehensive review of existing condition monitoring systems for railway wheels is conducted in this paper. The review is aimed at understanding the feasibility and potential of new methods for modern railways. This paper provides a detailed overview of studies on the existing wayside systems and reports their advantages and disadvantages concerning its recently emerging counterpart on-board monitoring systems. Data acquisition systems and analysis methods are critically reviewed which could assist in developing more efficient and reliable condition monitoring systems for railway wheels. This article also reviews the current progress of wayside systems and their limitations. The article is targeted at the researchers and engineers working in this domain, who can pave the way for developing advanced and cost-effective condition monitoring systems for railway wheels using modern technologies.

5 February 2024 in Journal of Mobile Multimedia
Verified
Journal Article
Closed access
PDF file
YJYahya Sameen Junejo
Yahya Sameen Junejo
FSFaisal Karim Shaikh
Faisal Karim Shaikh
BSBhawani Shankar
Bhawani Shankar
ASAli Akber Shah
Ali Akber Shah
WEWaleed Ejaz
Waleed Ejaz
Radio Access Networks (RAN) have been an integral part of the cellular mobile communication systems since the deployment of Global System for Mobile Communication (GSM) networks and later for the legacy Universal Mobile Telecommunication Systems (UMTS) and Long Term Evolution (LTE) networks. However, due to increasing demands of the users, throughput, ultra-lower latency, virtualization of the network and to cater the seamless connectivity of millions of wireless devices with the cellular networks, the advent of RAN needs to be brought under consideration. In this paper the traditional RANs are discussed with the necessity for their transition into the Open RAN (ORAN), considering all its essential parameters. The constraints of the legacy RAN architectures are explored with an overview of the RAN intelligent controllers, ORAN and its types. This paper additionally examines the function of artificial intelligence in Common Public Radio Interface (CPRI), enhanched CPRI, and xApps in terms of use cases along with the challenges associated with their deployment. The paper also present challenges and future of ORAN.


24 December 2024
Verified
Book Chapter
Open access
PDF file
ASAli Akbar Shah
Ali Akbar Shah
RAReihaneh Aghamolaei
Reihaneh Aghamolaei
ITIrina Tal
Irina Tal
DIDanish Inam
Danish Inam
IAInam Ul Ahad
Inam Ul Ahad
Considering the older buildings, the absence of architectural designs poses a significant obstacle, particularly during retrofitting endeavours. Project managers face the daunting task of acquiring missing information, which not only proves challenging but also consumes considerable time in the process. One of the main challenges is to measure the exterior dimensions of the building as measuring the height of the building is a tiresome process and often leads to inaccuracies in the observational readings. To address this, the study introduces a methodology for generating 3D model of a building by amalgamating building images sourced from Google Earth and has been conducted on an operational building. The methodology integrates advanced algorithms like photogrammetry for accurate measurements of the building exterior dimensions.

24 December 2024
Verified
Book Chapter
Open access
PDF file
ASAli Akbar Shah
Ali Akbar Shah
RAReihaneh Aghamolaei
Reihaneh Aghamolaei
ITIrina Tal
Irina Tal
SMSyed Muhammad
Syed Muhammad
KSKashif Shah
Kashif Shah
IAInam Ul Ahad
Inam Ul Ahad
Most of the old buildings, over their service lives absorbs carbon through processes such as carbonation in concrete and absorption in timber. In comparison with the newer buildings, the older buildings have less insulation which may make them less energy efficient. This study focuses on the analysis of the impact of the material insulation on the energy performance of the building. To determine this, a floor of the building is examined in this study using Building Information Modelling. In one model, the walls were made of a material with less insulation having thermal resistance (R), heat transfer coefficient (U) and thermal mass of 4.2386 (m2.K)/W, 0.2359 Q/ (m2.k), and 299.48 kJ/(m2/k), respectively. While in another model with same architectural parameters, the walls were made with material with high insulation having thermal resistance (R), heat transfer coefficient (U) and thermal mass of 5.2757 (m2.K)/W, 0.1895 W/ (m2.K), and 924.04 kJ/ (m2.K), respectively. The impact of the insulation on the energy consumption of the models were analysed using Autodesk Insight. The difference in the energy performance between the low insulation material and high insulation material was 1.9 USD/m2/yr., highlighting the importance of the insulation on the overall energy efficiency of the building.

24 December 2024
Verified
Book Chapter
Open access
PDF file
ASAli Akbar Shah
Ali Akbar Shah
ITIrina Tal
Irina Tal
RAReihaneh Aghamolaei
Reihaneh Aghamolaei
DIDanish Inam
Danish Inam
MSMuhammad Kashif Shah
Muhammad Kashif Shah
IAInam Ul Ahad
Inam Ul Ahad
Construction significantly contributes to Greenhouse Gas Emissions (GHGe), accounting for 40% of the total. These emissions are either due to the embodied carbon in construction materials or due to their operational carbon (energy consumption during the service life of the building). Considering the current standards, the newly constructed building complies by the rules and regulations initiated by the government to meet the international energy standards. However, these standards were just a decade old and many of the old constructions do not fit into the current energy standards. Infact most of the buildings in Europe were constructed prior to 1990s and for their daily operation, they heavily rely on energy. While the electric meter provides overall measurements of the electricity consumption for the entire building, it is imperative to recognize that the electricity usage within individual sections of the floor often holds greater insights. Directly monitoring of the electricity usage of specific floor areas allows for a more precise analysis and targeted interventions to optimize energy usage and efficiency within those sections. Therefore, in this study, a wireless sensor node specifically designed for measuring the electricity consumption of the building floors is developed. This sensor is compact, and it integrates a current transformer, and a wireless microcontroller module. The sensor operates on the principle of electromagnetic induction and converts the high primary current into proportionally lower secondary current for measurements. Lightweight and with minimal latency, the developed instrumentation efficiently collects the energy data.