The objective of the present work is to find out the optimal mass flux of two common refrigerants, R32 and R410A, undergoing boiling in an evaporator tube based on the entropy generation minimization approach. An entropy generation model is developed for two-phase boiling flow based on the drift flux approach. The distinct terms for entropy generation due to heat transfer and pressure drop are developed. The optimal solutions of the present model under a practical range of parametric conditions are compared with that obtained from the existing homogeneous and separated flow-based model. Analysis reveals that increasing the evaporator diameter and heat flux increases the optimal mass flux at minimum entropy generation for both refrigerants. On the other hand, increasing the evaporator length decreases the optimal mass flux. It is observed that the optimal mass flux data for all parametric conditions deviate within 10–15% on the positive and negative sides for drift flux and homogeneous models, respectively, compared to separate flow model. The present analysis also reveals that the overall deviation of data of the drift flux model and homogeneous flow model indicates a standard deviation of 1.95–1.98%, respectively.
6 August 2020 in Journal of Thermal Science and Engineering Applications
In the present work, a numerical model is developed to analyze the riser-downcomer system of a natural circulation steam generator. The design and operation of the riser-downcomer system involve many complex issues such as multiphase flow inside the riser tubes, numerous possibilities of different flow regimes, and undesirable tube overheating due to the occurrence of critical heat flux (CHF). A separated flow model is developed to analyze steam-water two-phase flow inside the heated riser tubes. Further, the model is coupled with the implementation of the complex flow regime map and evaluation of wall temperature rise of the riser tubes. The present model is adequately validated with the existing experimental and numerical data as a direct problem. The model accuracy in predicting the tube dry-out and practical design is tested with the experimental data and real plant data, respectively. A typical 600 MW thermal power plant boiler is then investigated along with techno-economic efforts to find the possible design solutions of the boiler riser-downcomer circuit. The safe and unsafe zones of operations have been identified in the present study and, consequently, a range of feasible design solutions is provided in great detail. The diameters and thicknesses of the tubes used in the present analysis are in compliance with the ASME boiler code.
20 July 2023 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Cavitation in fluids can severely hinder the efficiency of the associated flows. This undesired phenomenon is strongly influenced by local flow conditions, flow orientation, proximity to boundaries, and liquid/gas properties at saturation. When liquid flow is severely constricted and cavitation occurs, diverging microchannels can suppress vapor formation through effective pressure recovery; however, the behavior of such microchannels under different geometric and operating conditions remains unclear. This work combines experimental data and computational modeling to elucidate the intricate flow dynamics of cavitation-induced phase change of refrigerant (R134a) flow in a Venturi-type microchannel. Full-field numerical simulations are carried out using the interPhaseChangeFoam solver in OpenFOAM®, with the model coefficients being validated against experimental data obtained with an identical system. The effects of flow rate, channel opening angle, and inlet cross-sectional geometry are explored with a focus on pressure drop, velocity distribution, and cavitation characteristics, including vapor fraction. The results highlight the roles of flow velocity, orifice-to-channel width ratio, orifice size, and channel divergence angle on overall pressure drop. A channel opening angle of 12° minimizes pressure drop, in contrast with conventional single-phase Venturi geometries where the optimal opening angle typically lies between 5° and 7°. The study underscores that the cavitation number, including its sign, serves as a critical quantitative indicator of cavitation severity—where increasingly negative values correspond to intensified vapor generation in microscale constrictions. By identifying the relationships between operating conditions and cavitation phenomena, this work provides a framework for understanding and optimizing microchannel designs under conditions prone to cavitation.