Mohammad Hasan Imam

Mohammad Hasan Imam

Auto-generated profile, based on publicly available information

Mohammad Hasan Imam

Department of Electrical and Electronic Engineering, American International University-Bangladesh (AIUB), Dhaka, Bangladesh

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019
Verified
Conference Paper
Closed access
FRFahim Rizwan
Fahim Rizwan
RFRayed Farhad
Rayed Farhad
FMFarhan Mashuk
Farhan Mashuk
FIFakhrul Islam
Fakhrul Islam
MIMohammad Hasan Imam
Mohammad Hasan Imam
This study represents a design of a detection system of stress through machine learning using some available bio signals in human body. Stress can be commonly defined as the disturbance in psychological equilibrium. Stress detection is one of the major research areas in biomedical engineering as proper detection of stress can conveniently prevent many psychological and physiological problems like cardiac rhythm abnormalities or arrhythmia. There are several bio-signals available (i.e. ECG, EMG, Respiration, GSR etc.) which are helpful in detecting stress levels as these signals shows characteristic changes with stress induction. In this paper, ECG was selected as the primary candidate because of the easily available recording (i.e. several mobile clinical grade recorders are available now in the market) and ECG feature extraction techniques. Another advantage of ECG is that respiratory signal information can also be detected form ECG which is known as EDR (ECG derived Respiration) without having separate sensor system for respiration measurement. Features of ECG signals are distinctive and collection of the signals is cost-efficient. From ECG we derived RR interval, QT interval, and EDR features for the development of the model. For the implementation of a supervised machine learning (SVM) method in MATLAB, Physionet's "drivedb" database was used as the training dataset and validation. SVM was chosen for classification, as there are two classes of labeled data; `stressed' or `non-stressed'. Several SVM model types were verified by changing the feature number and Kernel type. Our results showed an accuracy level of 98.6% with Gaussian Kernel function and using all available features (RR, QT and EDR), which also emphasizes the importance of respiratory information in stress detection through Machine Learning.

1 January 2013 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
HJHerbert Jelinek
Herbert Jelinek
HIHasan Md Imam
Hasan Md Imam
Hayder Al-AubaidyHayder Al-Aubaidy
Hayder Al-Aubaidy
AKAhsan Khandoker
Ahsan Khandoker
Cardiovascular risk can be calculated using the Framingham cardiovascular disease (CVD) risk score and provides a risk stratification from mild to very high CVD risk percentage over 10 years. This equation represents a complex interaction between age, gender, cholesterol status, blood pressure, diabetes status, and smoking. Heart rate variability (HRV) is a measure of how the autonomic nervous system (ANS) modulates the heart rate. HRV measures are sensitive to age, gender, disease status such as diabetes and hypertension and processes leading to atherosclerosis. We investigated whether HRV measures are a suitable, simple, noninvasive alternative to differentiate between the four main Framingham associated CVD risk categories. In this study we applied the tone-entropy (T-E) algorithm and complex correlation measure (CCM) for analysis of HRV obtained from 20 min. ECG recordings and correlated the HRV score with the stratification results using the Framingham risk equation. Both entropy and CCM had significant analysis of variance (ANOVA) results [F(172, 3) = 9.51; <0.0001]. Bonferroni post hoc analysis indicated a significant difference between mild, high and very high cardiac risk groups applying tone-entropy (p < 0.01). CCM detected a difference in temporal dynamics of the RR intervals between the mild and very high CVD risk groups (p < 0.01). Our results indicate a good agreement between the T-E and CCM algorithm and the Framingham CVD risk score, suggesting that this algorithm may be of use for initial screening of cardiovascular risk as it is noninvasive, economical and easy to use in clinical practice.

1 April 2018
Verified
Conference Paper
Closed access
IIIftekhar Islam
Iftekhar Islam
MRMaruf Hossain Raj
Maruf Hossain Raj
SNShantanu Nath
Shantanu Nath
FRForhadur Rahman
Forhadur Rahman
SHSabbir Hossen
Sabbir Hossen
MIMohammad Hasan Imam
Mohammad Hasan Imam
This paper represents the design and implementation of an indoor based navigation system for visually impaired people using a path finding algorithm and a wearable cap. This development of the navigation system consists of two modules: a Wearable part and a schematic of the area where the navigation system works by guiding the user. The wearable segment consists of a cap designed with IR receivers, an Arduino Nano processor, a headphone and an ultrasonic sensor. The schematic segment plans for the movement directions inside a room by dividing the room area into cells with a predefined matrix containing location information. For navigating the user, sixteen IR transmitters which continuously monitor the user position are placed at equal interval in the XY (8 in X-plane and 8 in Y-plane) directions of the indoor environment. A Braille keypad is used by the user where he gave the cell number for determining destination position. A path finding algorithm has been developed for determining the position of the blind person and guide him/her to his/her destination. The developed algorithm detects the position of the user by receiving continuous data from transmitter and guide the user to his/her destination by voice command. The ultrasonic sensor mounted on the cap detects the obstacles along the pathway of the visually impaired person. This proposed navigation system does not require any complex infrastructure design or the necessity of holding any extra assistive device by the user (i.e. augmented cane, smartphone, cameras). In the proposed design, prerecorded voice command will provide movement guideline to every edge of the indoor environment according to the user's destination choice. This makes this navigation system relatively simple and user friendly for those who are not much familiar with the most advanced technology and people with physical disabilities. Moreover, this proposed navigation system does not need GPS or any telecommunication networks which makes it suitable for use in rural areas where there is no telecommunication network coverage. In conclusion, the proposed system is relatively cheaper to implement in comparison to other existing navigation system, which will contribute to the betterment of the visually impaired people's lifestyle of developing and under developed countries.

24 April 2015 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MIMohammad Hasan Imam
Mohammad Hasan Imam
Chandan KarmakarChandan Karmakar
Chandan Karmakar
HJHerbert Jelinek
Herbert Jelinek
MPMarimuthu Palaniswami
Marimuthu Palaniswami
AKAhsan Khandoker
Ahsan Khandoker
In this study, a linear parametric modeling technique was applied to model ventricular repolarization (VR) dynamics. Three features were selected from the surface ECG recordings to investigate the changes in VR dynamics in healthy and cardiac autonomic neuropathy (CAN) participants with diabetes including heart rate variability (calculated from RR intervals), repolarization variability (calculated from QT intervals), and respiration [calculated by ECG-derived respiration (EDR)]. Surface ECGs were recorded in a supine resting position from 80 agematched participants (40 with no cardiac autonomic neuropathy (NCAN) and 40 with CAN). In the CAN group, 25 participants had early/subclinical CAN (ECAN) and 15 participants were identified with definite/clinical CAN (DCAN). Detecting subclinical CAN is crucial for designing an effective treatment plan to prevent further cardiovascular complications. For CAN diagnosis, VR dynamics was analyzed using linear parametric autoregressive bivariate (ARXAR) and trivariate (ARXXAR) models, which were estimated using 250 beats of derived QT, RR, and EDR time series extracted from the first 5 min of the recorded ECG signal. Results showed that the EDR-based models gave a significantly higher fitting value (p <; 0.0001) than models without EDR, which indicates that QTRR dynamics is better explained by respiratory-information-based models. Moreover, the QT-RR-EDR model fitting values gradually decreased from the NCAN group to ECAN and DCAN groups, which indicate a decoupling of QT from RR and the respiration signal with the increase in severity of CAN. In this study, only the EDR-based model significantly distinguished ECAN and DCAN groups from the NCAN group (p <; 0.05) with large effect sizes (Cohen's d > 0.75) showing the effectiveness of this modeling technique in detecting subclinical CAN. In conclusion, the EDRbased trivariate QT-RR-EDR model was found to be better in detecting the presence and severity of CAN than the bivariate QTRR model. This finding also establishes the importance of adding respiratory information for analyzing the gradual deterioration of normal VR dynamics in pathological conditions, such as diabetic CAN.

1 December 2017
Verified
Conference Paper
Closed access
ZRZannatul Raiyan
Zannatul Raiyan
SNSakib Nawaz
Sakib Nawaz
AAA. K. M. Asif Adnan
A. K. M. Asif Adnan
MIMohammad Hasan Imam
Mohammad Hasan Imam
This paper represents the design of an Arduino based voice controlled automated wheelchair. The design is developed with a voice recognition system, which allows the physically disabled person to control the wheelchair by voice command who have issues in hand movement due to ageing or paralysis for joystick controlled wheelchairs. The design also provide some additional features such as obstacle detection for the safe movement and a GSM based navigation system for tracking and sending notifications to increase the usability of the automated wheelchair system. To implement the design, Arduino Mega2560, Easy VR3 speech recognition module, SIM900A GSM module and relay based motor controller circuits are used along with the wheelchair. The designed wheelchair system does not require any wearable sensors for using other biomedical signals to control wheelchair movement (i.e. EEG, EMG, EOG sensors) as reported in several research studies which require complex signal processing techniques done with an extra bulky computing system attached with the wheelchair. In the proposed design, the speech processing is done solely with the available integrated speech processing module (Easy VR3) which removes the necessity of any bulky complex extra computing device. Moreover, the proposed technique is relatively simple and cheaper to implement with the widely used available electronic devices in comparison to other existing techniques which will have a great impact on the societies of developing and under developing countries.

29 July 2015 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
MIMohammad Hasan Imam
Mohammad Hasan Imam
Chandan KarmakarChandan Karmakar
Chandan Karmakar
HJHerbert Jelinek
Herbert Jelinek
MPMarimuthu Palaniswami
Marimuthu Palaniswami
AKAhsan Khandoker
Ahsan Khandoker
Cardiac autonomic neuropathy (CAN), one of the major complications in diabetes, if detected at the subclinical stage allows for effective treatment and avoiding further complication including cardiovascular pathology. Surface ECG (Electrocardiogram)-based diagnosis of CAN is useful to overcome the limitation of existing cardiovascular autonomic reflex tests traditionally used for CAN identification in clinical settings. The aim of this paper is to analyze the changes in the mechanical function of the ventricles in terms of systolic-diastolic interval interaction (SDI) from a surface ECG to assess the severity of CAN progression [no CAN, early CAN (ECAN) or subclinical CAN, and definite CAN (DCAN) or clinical CAN]. ECG signals recorded in supine resting condition from 72 diabetic subjects without CAN (CAN-) and 70 diabetic subjects with CAN were analyzed in this paper. The severity of CAN was determined by Ewing's Cardiovascular autonomic reflex tests. Fifty-five subjects of the CAN group had ECAN and 15 subjects had DCAN. In this paper, we propose an improved version of the SDI parameter (i.e., TQ/RR interval ratio) measured from the electrical diastolic interval (i.e., TQ interval) and the heart rate interval (i.e., RR interval). The performance of the proposed SDI measure was compared with the performance of the existing SDI measure (i.e., QT/TQ interval ratio). The proposed SDI parameter showed significant differences among three groups (no CAN, ECAN, and DCAN). In addition, the proposed SDI parameter was found to be more sensitive in detecting CAN progression than other ECG interval-based features traditionally used for CAN diagnosis. The modified SDI parameter might be used as an alternative measure for the Ewing autonomic reflex tests to identify CAN progression for those subjects who are unable to perform the traditional tests. These findings could also complement the echocardiographic findings of the left ventricular diastolic dysfunction by providing additional information about alteration in systolic and diastolic intervals in heart failure.