15 January 2011 in Electric Power Systems Research
11 December 2008 in Electric Power Components and Systems
This article proposes a hybrid energy system combining solar photovoltaic and wind turbine as a small-scale alternative source of electrical energy where conventional generation is not practical. A simple and cost-effective control technique has been proposed for maximum power point tracking from the photovoltaic array and wind turbine under varying climatic conditions without measuring the irradiance of the photovoltaic or the wind speed. The proposed system is attractive because of its simplicity, ease of control, and low cost. A complete description of the proposed hybrid system, along with detailed simulation results that ascertain its feasibility, are given to demonstrate the availability of the proposed system in this article. Simulation of the hybrid system under investigation was carried out using PSIM software.
26 October 2008 in Measurement
1 September 2015 in EPE Journal
This paper presents a fast and effective optimal solution of harmonic elimination of multilevel inverters with unbalanced DC sources using fuzzy linear programming (FLP). A set of non-linear mathematical models containing a description of the general output waveform of cascaded H-bridge multilevel inverters with unbalanced DC sources, will be formulated. An objective function will be employed to obtain an optimal solution for a set of switching instances to eliminate undesired harmonics. The solution algorithm will also control the output voltage level at the desired fundamental component. FLP is used to obtain an accurate and fast solution to minimize the linearized objective function and identify the desired set of switching angles. The proposed fuzzy linear programming is tested both in simulation and experimentally, for different cases of multilevel inverters to verify the accuracy of the results.
23 February 2007 in Electric Power Components and Systems
This article presents a novel algorithm for identifying and measuring the symmetrical components of three phase voltage or current waveforms in electrical power systems. The problem is formulated as an estimation problem and presented in state space form. A particle swarm optimization (PSO) is employed to minimize the error associated with the estimated parameters. The proposed algorithm is used to estimate the positive, negative and zero components of unsymmetrical waveforms. Application of the proposed algorithm has been conducted on various test cases, among which a practical simulated power system has been implemented in Simulink using its power system block set. Various abnormal scenarios were carried out (such as line to ground, line to line to ground, as well as unbalanced load) in order to create realistic situation of unsymmetrical waveforms. Different factors affecting the identification process, such as data window size, sampling frequency, and the number of samples, are studied. Effects of bad data on the solution accuracy are also considered. Results obtained show that the proposed technique efficiently estimates the symmetrical components of three phase unbalance voltage or current waveforms.