Muhammad Usama Usman

Muhammad Usama Usman

Auto-generated profile, based on publicly available information

Muhammad Usama Usman

Department of Electrical and Computer Engineering and the Center for Advanced Power Systems FAMU‐FSU College of Engineering, Florida State University 2000 Levy Avenue Tallahassee FL 32310 USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2018 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
MUMuhammad Usama Usman
Muhammad Usama Usman
MFMd Omar Faruque
Md Omar Faruque
Synchrophasors are time-synchronized electrical measurements that represent both the magnitude and phase angle of the electrical sinusoids. Synchrophasors are measured by fast time-stamped devices called phasor measurement units (PMUs) to constitute the basis of real-time monitoring and control actions in the electric grid. Due to its enhanced situational awareness capabilities, many applications of PMUs are presented in the literature in the past decades. This paper presents a comprehensive summary of synchrophasor technology, its architecture, optimal placement techniques and its applications in electric power transmission and distribution systems. These applications include wide-area situational awareness and monitoring, state estimation, fault location and protective relaying, islanding detection etc. This review also covers some of the existing challenges in its implementation and its potential applications.

2 October 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
MUMuhammad Usama Usman
Muhammad Usama Usman
OFOmar Faruque
Omar Faruque
A fault location (FL) identification method for smart distribution network is presented and validated using a digital real‐time simulator (DRTS). The method can accurately identify the FL in a distribution network in the presence of distributed generation (DG). This method is based on state estimation (SE) algorithm which uses real‐time data from simulated phasor measurement units (PMUs), placed in the distribution network. SE needs the fault currents of the generators and voltage measurements of an optimal number of nodes to perform the FL algorithm. The method was validated using the IEEE 37 node test feeder with DGs. PMUs are placed on the real‐time model of the system. The real‐time model was implemented on a DRTS which streams phasor data over the Internet using C37.118 protocol. OpenPDC is used to collect real‐time PMU data coming from the DRTS. Microsoft SQL is used as a database management server to store data coming from OpenPDC. In the last step of the FL process, data stored in OpenPDC is fed into a FL identification algorithm to locate the fault. Both balanced and unbalanced fault types are applied to different nodes and an accurate estimation of the FL (over 90% of the cases) is achieved.

1 August 2018
Verified
Conference Paper
Closed access
MUMuhammad Usama Usman
Muhammad Usama Usman
JOJuan Ospina
Juan Ospina
OFOmar Faruque
Omar Faruque
This paper presents a novel approach to classify and locate different types of faults in a smart distribution network (DN). The proposed method is able to classify all types of faults that can occur in a DN and then based on fault type, it can identify the approximate fault location (FL) with a high accuracy. The method is based on artificial neural networks pattern recognition which uses data from μPMUs/smart meters placed at different locations in a DN. The proposed technique needs fault-on voltages of all the nodes connected to the end of line/branches in order to classify and locate different types of faults. The method is tested on a modified IEEE-37 bus system with distributed generation along with dynamic loading conditions and varying fault resistances. Both balanced and unbalanced fault types are applied to the system. An accurate classification of 100% is achieved when classifying all fault types and above 99% accuracy is achieved when identifying the approximate fault location.

17 December 2018 in IEEE Access
Verified
Journal Article
Open access
LHLal Hussain
Lal Hussain
AAAmjad Ali
Amjad Ali
SRSaima Rathore
Saima Rathore
SSSharjil Saeed
Sharjil Saeed
AIAdnan Idris
Adnan Idris
DSDoug Young Suh
Doug Young Suh
Cancer is a major public health problem across the globe due to which millions of deaths occur every year. In the United States, prostate cancer is the second leading cause of cancer- related deaths in men. The major causes of prostate cancer include increasing age, family history, diet, sexual behavior, and geographic location. Early detection of prostate cancer can effectively reduce the mortality rate. In the past, researchers have adopted various multimodal feature extracting strategies to extract diverse and comprehensive quantitative imaging features and employed machine learning methods to detect prostate cancer. However, existing techniques lack detailed analysis of the magnitude of relationship among different individual discriminatory features, which is very important to understand the dynamics of the disease. In this study, we extracted diverse morphological features to summarize the imaging profile of patients of prostate cancer imaging database and employed Bayesian network analysis approach to quantify the association between different features and the strength of the association. The features and the association between the features were, respectively, modeled as the nodes and the edges of the network. The strength of association between the nodes was computed using Pearson’s correlation, mutual Information and Kullback–Liebler methods. The strongest associations were found between multiple features: (Area $\to $ Equidiameter), (Area $\to $ Circulatory 2), (Circulatory $1\to $ (Elongatedness), (Circulatory $1\to $ Entropy), (Circulatory $1\to $ Max. Radius), and (Min. Radius $\to $ Eccentricity). Moreover, interaction impact among nodes and node force was also computed. This analysis will help in finding the features that are more dominant to establish the relationship and can further increase the detection performance.

3 December 2019 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
MUMuhammad Usama Usman
Muhammad Usama Usman
JOJuan Ospina
Juan Ospina
OFOmar Faruque
Omar Faruque
This paper presents a real‐time fault classification and location identification method for a smart distribution network (DN) using artificial neural networks (ANNs) and advanced metering infrastructure (AMI). It also describes the development of a testbed for real‐time testing of the proposed approach. The testbed consists of a simulated power system model [running on a digital real‐time simulator (DRTS)] and AMI. The core parts of AMI are smart meters (SMs), a communication network (developed using DNP3 protocol over transfer control protocol/Internet protocol), data concentrator (DC), and a Utility Operations Centre (UOC). Event‐driven data from SMs are collected in the DC and then fed to the UOC for being used as inputs for the novel ANN‐based fault classification and location identification algorithm. On the basis of the data received, the algorithm can classify the fault type and locate it with high accuracy. Both balanced and unbalanced fault types are tested on different nodes and lines throughout a DN modelled in offline and on the DRTS. A comprehensive sensitivity analysis is performed to validate the effectiveness of the proposed method. Classification accuracy of over 99% is achieved when classifying all fault types, and above 95% accuracy is achieved when identifying the fault location.

1 March 2014
Verified
Conference Paper
Closed access
MUMuhammad Usman Usama
Muhammad Usman Usama
DKDavid Kelle
David Kelle
TBThomas Baldwin
Thomas Baldwin
Energy Storage Systems (ESS) show much promise for mitigating the dynamics introduced by nondispatchable variable generation. By taking advantage of spinning reserves as a form of flywheel energy storage, the fossil fuel power plant becomes a form of ESS. The spare power capacity in the generator and prime mover represent the throughput of the ESS and the stockpile of fuel defines the energy capacity. The ESS discharging and charging behavior can be seen as increasing and decreasing the fuel pile usage. Similar forms of energy storage have been recently implemented using gas turbines with fast dynamic responses, which are necessary for renewable generation. Criticism of fossil fuel generation focuses on high operational costs of thermal power plants. However, the cost of operating a thermal power plant compares favorably to the cost of implementing other forms of ESS such as battery storage. Utilizing thermal plants in this way allows for reliable increase of renewable penetration, and reduces capital and operating cost. This paper presents analysis tools necessary to properly evaluate the economics of energy storage provided by thermal plants. These tools also balance the available energy storage against spinning reserve requirements for system reliability.