Shirsha Bose

Shirsha Bose

Auto-generated profile, based on publicly available information

Shirsha Bose

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland.; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland.; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2024
Verified
Conference Paper
Closed access
MSMainak Singha
Mainak Singha
AJAnkit Jha
Ankit Jha
SBShirsha Bose
Shirsha Bose
ANAshwin Nair
Ashwin Nair
MAMoloud Abdar
Moloud Abdar
Biplab BanerjeeBiplab Banerjee
Biplab Banerjee
We delve into Open Domain Generalization (ODG), marked by domain and category shifts between training's labeled source and testing's unlabeled target domains. Existing solutions to ODG face limitations due to constrained generalizations of traditional CNN backbones and errors in detecting target open samples in the absence of prior knowledge. Addressing these pitfalls, we introduce ODG-CLIP, harnessing the semantic prowess of the vision-language model, CLIP. Our framework brings forth three primary innovations: Firstly, distinct from prevailing paradigms, we conceptualize ODG as a multi-class classification challenge encompassing both known and novel categories. Central to our approach is modeling a unique prompt tailored for detecting unknown class samples, and to train this, we employ a readily accessible stable diffusion model, elegantly generating proxy images for the open class. Secondly, aiming for domain-tailored classification (prompt) weights while ensuring a balance of precision and simplicity, we devise a novel visual stylecentric prompt learning mechanism. Finally, we infuse images with class-discriminative knowledge derived from the prompt space to augment the fidelity of CLIP's visual embeddings. We introduce a novel objective to safeguard the continuity of this infused semantic intel across domains, especially for the shared classes. Through rigorous testing on diverse datasets, covering closed and open-set DG contexts, ODG-CLIP demonstrates clear supremacy, consistently outpacing peers with performance boosts between 8%-16%. Code will be available at https://github.com/mainaksingha01/ODG-CLIP.

5 November 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SBShirsha Bose
Shirsha Bose
MKMajid Akbarzadeh Khorshidi
Majid Akbarzadeh Khorshidi
CLCaitriona Lally
Caitriona Lally

28 June 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
MKMajid Akbarzadeh Khorshidi
Majid Akbarzadeh Khorshidi
SBShirsha Bose
Shirsha Bose
BWBrian Watschke
Brian Watschke
EMEvania Mareena
Evania Mareena
CLCaitriona Lally
Caitriona Lally
This paper presents an inverse finite element (FE) approach aimed at estimating multi-layered human penile tissues. The inverse FE approach integrates experimental force-displacement and boundary deformation data of penile tissues with a developed FE model and uses new experimental data on human penile tissue. The experimental study encompasses whole organ plate-compression tests and individual layer tensile and compression tests, providing comprehensive insights into the tissue's mechanical behaviour. The biomechanical characterisation of penile tissue is of crucial significance for understanding its mechanical behaviour under various physiological and pathological conditions. The FE model is constructed using the realistic geometry of the penile segment and appropriate constitutive models for each tissue layer to leverage the accuracy and consistency of the model. Through systematic variation of tissue parameters in the inverse FE algorithm, simulations achieve the best match with both force-displacement and deformed boundary results obtained from the whole organ plate-compression tests. Test results from individual tissue layers are also utilised to assess the estimated parameters. The proposed inverse FE approach allows for the estimation of penile tissue parameters with high precision and reliability, shedding light on the mechanical properties of this complex biological organ. This work has applications not only in urology but also for researchers in various disciplines of biomechanics. As a result, our study contributes to advancing the understanding of human penile tissue mechanics whilst the methodology could also be applied to a range of other soft biological tissues. STATEMENT OF SIGNIFICANCE: This research uses a multi-target inverse finite element (FE) approach for estimating the material parameters of human penile tissues. By integrating experimental data and a realistic FE model, this study achieves high-precision constitutive model parameter estimation, offering key insights into penile tissue mechanics under various loading conditions. The significance of this work lies in the use of this inverse FE approach for fresh-frozen human penile tissues, to identify the mechanical properties and constitutive models for both segregated tunica albuginea and corpus cavernosum as well as intact penile tissue segments. The study's scientific impact lies in its advancement of the understanding of human urological tissue mechanics, impacting researchers and clinicians alike.

26 September 2023 in Computers in Biology and Medicine
Verified
Journal Article
Open access
BFB. Fereidoonnezhad
B. Fereidoonnezhad
MKM. Akbarzadeh Khorshidi
M. Akbarzadeh Khorshidi
SBS. Bose
S. Bose
BWB. Watschke
B. Watschke
EME. Mareena
E. Mareena
CLCaitriona Lally
Caitriona Lally
This paper presents a computational study to investigate the mechanical properties of human penile tissues. Different experimental testing regimes, namely indentation and plate-compression tests, are compared to establish the most suitable testing regime for establishing the mechanical properties of the different penile tissues. An idealised MRI-based geometry of the penis , containing different tissue layers, is simulated using the finite element (FE) method to enable realistic predictions of the deformation of the penis. Unlike the linear elastic models used in the literature to-date, hyperelastic isotropic/anisotropic material models are used to capture material nonlinearity and anisotropy. The influence of material properties, morphological variations, material nonlinearity and anisotropy are investigated. Moreover, the implantation of an inflatable penile prosthesis (IPP) is simulated to assess the effects of the implantation procedure, material nonlinearity, and anisotropy on tissue stresses. The results indicate that the interior layers of the penis do not affect the overall stiffness of the penis in the indentation test, while the plate-compression test is able to capture the effects of these layers. Tunica Albuginea (TA) is found to have the most significant contribution to the total stiffness of the penis under load. It can also be observed that buckling occurs in the septum of the penis during the compression tests, and different morphologies dictate different compressive behaviours. There is a clear need for future experimental studies on penile tissues given the lack of relevant test data in the literature. Based on this study, plate-compression testing would offer the most insightful experimental data for such tissue characterisation.

15 March 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
SBShirsha Bose
Shirsha Bose
MKMajid Akbarzadeh Khorshidi
Majid Akbarzadeh Khorshidi
RJRobert Daniel Johnston
Robert Daniel Johnston
BWBrian Watschke
Brian Watschke
EMEvania Mareena
Evania Mareena
CLCaitriona Lally
Caitriona Lally
Erectile dysfunction (ED) predominantly affects men in their 40-70s and can lead to a poor quality of life. One option for ED treatment is surgical implantation of an inflatable penile prosthesis (IPP). However, they can be associated with negative outcomes including infection, migration or fibrosis. To improve outcomes, the interaction between the IPP device and surrounding tissues needs further investigation and this could be achieved using pre-clinical testbeds, but they need to be informed by extensive tissue testing. In this study, an experimental approach is adopted to characterise the mechanics of horse penile tissue and establish a testing protocol for penile tissue. The whole penis segments were tested in plate compression tests to obtain whole penis behaviour which is necessary for validation of a pre-clinical testbed, whilst tensile and compression tests were performed on individual penile tissues, namely corpus cavernosa and tunica albuginea. The second part of the paper deals with the development of a computational model employing an inverse finite element approach to estimate the material parameters of each tissue layer. These material parameters are in a good agreement with the experimental results obtained from the individual tissue layers and whole organ tissue tests. This paper presents the first study proposing realistic nonlinear elastic material parameters for penile tissues and offers a validated testbed for IPPs. STATEMENT OF SIGNIFICANCE: Erectile Dysfunction (ED) affects over half the male population aged 40-70 potentially leading to a poor quality of life. Patients not responding to conventional treatments of ED, are advised to use penile prostheses which can create an erection using implanted inflatable cylinders. A significant drawback of such prostheses, however, is the substantial tissue damage they can induce during their usage. Preclinical testbeds, including computational and bench-top models, could offer an efficient means of improving device designs to mitigate this damage but such testbeds require extensive knowledge of penile tissue properties. In this study, the authors determine penile tissue mechanics and apply an inverse FE approach to characterise the penile material properties required to validate preclinical models of the penis.

28 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
RJRobert Daniel Johnston
Robert Daniel Johnston
CMCiara McKenna
Ciara McKenna
COConor O&Apos;Keeffe
Conor O&Apos;Keeffe
NLNiall Linnane
Niall Linnane
SGSamuel Geraghty
Samuel Geraghty
CLCatriona Lally
Catriona Lally
Aortic coarctation accounts for 5–8% of congenital heart disease and occurs in up to 6 in every 10,000 live births. While neonatal coarctation is typically treated surgically via thoracotomy and end-to-end anastomosis, endovascular stenting has become the preferred intervention in older children and adults. Despite favourable short-term outcomes, current stent therapies remain associated with long-term risks including persistent hypertension, and this may be linked to mostly off-label use of biliary stents which limit treatment efficacy in paediatric patients. Recent advances in additive manufacturing provide an opportunity to develop bespoke metallic stents tailored to patient-specific anatomy and biomechanics.,Here, we present a preclinical framework for the design, optimisation, fabrication, and evaluation of patient-specific stents for aortic coarctation treatment. Using selective laser melting (SLM) and finite element (FE) modelling, we developed a virtual design platform to generate and optimise Ti6Al4V stent geometries for varying severities of aortic narrowing (10%, 25%, 37.5%, and 50%). The resulting stent designs, with strut width and thickness dimensions ranging from 197.50 × 190.96 µm to 296.50 × 200 µm, were optimised to achieve a target post-expansion lumen diameter of 10 mm while minimising vessel wall stress. Furthermore, modifications to the connector geometry (original to C-connector and S-connector) enhanced stent conformability and reduced vessel wall stress by up to 16.7% and 19%, respectively. Candidate stents were subsequently fabricated by additive manufacturing, post-processed, and mechanically characterised in accordance with relevant regulatory testing standards. Finally, stent deployment was assessed computationally, through benchtop and ex vivo models to evaluate functional performance and deployment feasibility, establishing that optimised Ti6Al4V stents can be used for treatment of aortic coarctations.,Collectively, this work establishes an integrated computational and manufacturing workflow for the development of customised stents for aortic coarctation and demonstrates the potential of additive manufacturing to enable next-generation patient-specific cardiovascular implants.