1 November 2013 in IEEE Transactions on Power Electronics
A common-mode (CM) filter based on the LCL filter topology is proposed in this paper, which provides a parallel path for ground currents and which also restricts the magnitude of the EMI noise injected into the grid. The CM filter makes use of the components of a line to line LCL filter, which is modified to address the CM voltage with minimal additional components. This leads to a compact filtering solution. The CM voltage of an adjustable speed drive using a PWM rectifier is analyzed for this purpose. The filter design is based on the CM equivalent circuit of the drive system. The filter addresses the adverse effects of the PWM rectifier in an adjustable speed drive. Guidelines are provided on the selection of the filter components. Different variants of the filter topology are evaluated to establish the effectiveness of the proposed circuit. Experimental results based on EMI measurement on the grid side and the CM current measurement on the motor side are presented. These results validate the effectiveness of the filter.
5 January 2015 in IEEE Transactions on Industry Applications
Electromagnetic interference (EMI) noise is one of the major issues during design of grid-tied power converters. A novel LCL filter topology for a single-phase pulsewidth modulation (PWM) rectifier that makes use of bipolar PWM method is proposed for a single-phase to three-phase motor drive power converter. The proposed topology eliminates high dv/dt from the dc-bus common-mode (CM) voltage by making it sinusoidal. Hence, the high-frequency CM current injection to the ground and the motor-side CM current are minimized. The proposed filter configuration makes the system insensitive to circuit nonidealities such as mismatch in inductors values, unequal turn-on and turn-off delays, and dead-time mismatch between the inverter legs. Different variants of the filter topology are compared to establish the effectiveness of the proposed circuit. Experimental results based on the EMI measurement on the grid side and the CM current measurement on the motor side are presented for a 5-kW motor drive. It is shown that the proposed filter topology reduces the EMI noise level by about 35 dB.
12 March 2018 in IEEE Transactions on Power Delivery
Peak fault current and energy dissipation in high-voltage direct current (HVdc) circuit breakers (CBs) are very important parameters that impact dc grid protection development. This paper analyzes a hybrid DCCB (HCB) control that reduces peak current and energy dissipation by regulating the voltage across contacts of the ultrafast disconnector (UFD). This is achieved by manipulating the number of inserted surge arresters while contacts of the UFD are moving apart. The controller is seamlessly integrated with the current controller of HCBs. An analytical model for current and energy calculation is presented, verified, and employed for parametric studies. A PSCAD simulation with 320-kV, 16-kA test circuit confirms that the proposed voltage control reduces the peak current and energy dissipation by around 20%-30%. A 900-V, 500-A HCB laboratory hardware is described and the experimental results are shown to corroborate simulation conclusions.
1 December 2020 in IEEE Transactions on Power Electronics
Power semiconductor devices have maximum junction temperature limits, but it is not straightforward to sense or infer temperature inside sealed devices in running converters. One method is to observe electrical behaviour that is temperature dependent. For example, in some Gallium Nitride(GaN) power semiconductor devices, the maximum slope of the device current at turn-on has been shown to reduce as the junction temperature increases. This paper demonstrates the first non-contact over-temperature protection circuit for GaN power devices that exploits this effect and overcomes the complication that this inverse proportionality is affected by load current. A variant of a previously reported magnetic field "Infinity Sensor", named after its figure-of-eight topology and high bandwidth(>200MHz), measures di/dt. Using the sensor signal as the only input, a detection circuit finds peak di/dt, and a high-speed integrator derives instantaneous load current. The reference voltage for the decision-making part of the circuit is automatically adjusted as a function of load current, in order to counteract the dependency of di/dt on load current. Experimental results on a 400V, 2kW buck converter show the protection circuit successfully activating within 5oC of a pre-programmed junction temperature setting, independently of load current, for settings of 100oC, 120oC, and 140oC.
1 June 2017 in IET Power Electronics
Ground leakage current in a power converter is a major concern, which has stringent limitations due to safety concerns. Presence of high‐frequency pulses, with high d v /d t due to switching actions in common‐mode (CM) voltage, result in injection of current waveforms with large d i /d t spikes into the ground and causes high electromagnetic interference (EMI) noise level. In this study, a new method is proposed to make the CM voltage, of a single‐phase grid‐connected inverter, sinusoidal and free of high‐frequency pulses. The proposed method consists of two parallel connected H‐bridge power converters, which uses unipolar pulse width modulation (PWM) with carrier interleaving angle of 180°. The proposed method reduces the ground leakage current by more than an order of magnitude. A novel modification to the LCL filter is proposed which further reduces the leakage current by 48%. It is shown that these modifications make the overall system insensitive to circuit non‐idealities. Experimental results based on ground leakage current measurements on a 7.5 kW parallel single‐phase PWM rectifier are presented. These results validate the effectiveness of the proposed method.