Olexii Marushchak

Olexii Marushchak

Auto-generated profile, based on publicly available information

Olexii Marushchak

Sytenko Institute of Spine and Joint Pathology National Academy of Medical Sciences of Ukraine, Kharkiv, Ukraine

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2016 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
Volodymyr FilipenkoVolodymyr Filipenko
Volodymyr Filipenko
ОMОleksey Marushchak
Оleksey Marushchak
SBStanislav Bondarenko
Stanislav Bondarenko

20 June 2025 in TRAUMA
Verified
Journal Article
Open access
PDF file
SBS.YE. Bondarenko
S.YE. Bondarenko
Volodymyr FilipenkoVolodymyr Filipenko
Volodymyr Filipenko
YOYe.V. Olinkevych
Ye.V. Olinkevych
OMO.P. Marushchak
O.P. Marushchak
MKM.YU. Karpinsky
M.YU. Karpinsky
OYO.V. Yaresko
O.V. Yaresko
Background. One of the problems in revision hip arthroplasty is the removal of the stable femoral component. The use of a cerclage wire for fixing the bone flap after osteotomy raises several unresolved issues: the choice of the optimal number of the osteotomized flap fixation levels, the number of cerclage wire turns, and the degree of postoperative load on the operated lower limb. The purpose was to conduct a comparative analysis of the stress values in the femoral model with a revision stem after extended proximal osteotomy (ETO) depending on the options for fixing the bone flap with a cerclage wire. Materials and methods. A basic finite element model of the femur with a revision endoprosthesis was created. It contained femur, revision endoprosthesis, and bone flap. Three options for fixing the bone flap at one, two, and three levels were modeled. Two turns of a cerclage wire with a diameter of 1.5 mm were applied at each level. The model was loaded with a distributed force of 1100 N. Results. When fixing the bone flap at one level, the maximum stresses in the femur are determined at the distal part of its diaphysis — 48.1 and 43.9 MPa, respectively, from the medial and lateral sides. The minimum stress level of 8.7 MPa was revealed in the bone flap, which is explained by the presence of interfragmentary regenerate between it and the femur, which performs a damping function. Stresses in the endoprosthesis tend to increase from 158.8 MPa in the neck to 213.4 MPa at the proximal end of the stem. The maximum stress level of 834.1 MPa is observed in a cerclage wire, which is 1.6 times higher than the tensile strength of surgical steel and can cause wire breakage. Fixation of the bone flap with a cerclage wire at two levels leads to a decrease in stress values at all control points on the femur. A decrease in stress values by 2 times was determined in a cerclage wire, which is associated with the redistribution of loads to two fixation points. The wire winding at the third level practically didn’t influence the stress distribution in the bone elements of the model. Conclusions. Fixation of the bone flap at two and three levels does not significantly affect stresses in the femur but allows you to halve the magnitude of stress in the wire itself, which with a single-level fixation can exceed the tensile strength of surgical steel. In the absence of technical possibilities to perform fixation at several levels, a single-level fixation can be applied under the conditions of using a wire winding of at least 4 turns and a load on the operated limb of no more than 50 %. The optimal option for fixing the bone flap is a two-level cerclage fixation, which provides a reduction in stresses in the wire below the tensile strength of surgical steel. Although a three-level fixation provides an even greater reduction in stresses in the wire to 326.2 MPa, the difference compared to a two-level fixation is not so significant as to justify additional tissue trauma and extending the operation time. Limiting the load on the operated limb to 50 % allows reducing the tension in a cerclage wire below critical values even with a single-level fixation, which can be recommended for the early postoperative period until a sufficiently strong interfragmentary regenerate is formed.

16 January 2024 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
PDF file
MKMykola Korzh
Mykola Korzh
OPOlexii Popsuishapka
Olexii Popsuishapka
VLValerii Lytvyshko
Valerii Lytvyshko
ISIgor Shevchenko
Igor Shevchenko
YDYaroslav Doluda
Yaroslav Doluda
ZAZorik Arutunan
Zorik Arutunan
Due to the military conflict in Ukraine, the problem of treating gunshot fractures has become acute, which requires an urgent solution. Objective. On the basis of own experience, to determine the primary problems in the treatment of gunshot diaphyseal fractures of the long bones of the limbs and evaluate the preliminary results. Methods. The treatment process and its results were analyzed in 128 victims with gunshot fractures of long limb bones for the period 08.2022–08.2023. Classical methods of clinical, X-ray and laboratory investigations were used. The assessment was carried out according to the AO classification, that was supplemented with new options for tangent and perforated bone injuries, as well as the volume of destruction of adjacent soft tissues. Wounds of all the patinets were treated using vacuum aspiration, the fragments were fixed with external devices manufactured by Biomet, Stryker, ТОВ «Ейч Ві Орто», ОРТОПАК. Results. The analysis showed that 64 (50 %) of the wounded had a need to take additional measures to preserve or improve the position of the fragments: improvement of the geometry of the external apparatus, replacement of the apparatus with a more perfected one, with a plate or intramedular osteosynthesis; replacement of the apparatus with a plaster bandage or orthosis. Conclusions. Based on the study, it can be argued, that most gunshot diaphyseal fractures of long bones are multifragmental and accompanied with destruction of predominantly peripherally located soft tissues. At the same time, the periosteum with a layer of adjacent muscles for the most part retains integrity, viability and connection with the surface of the fragments. The basic and rational method of fixation of fragments for diaphysical gunshot fractures it is necessary to consider external osteosynthesis with schanz-screws devices. According to our preliminary data, the use of external fixator treatment led to fracture healing in 84% of patients with gunshot hip fracture, 56 % — tibia fracture, 59 % — humerus fracture, and 44 % — forearm fractures.

18 October 2023 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
PDF file
ATAndrej Trampuz
Andrej Trampuz
OPOlga Pidgaiska
Olga Pidgaiska
Volodymyr FilipenkoVolodymyr Filipenko
Volodymyr Filipenko
KRKostiantyn Romanenko
Kostiantyn Romanenko
OMOlexii Marushchak
Olexii Marushchak
Fracture-related infection following orthopedic surgery, especially in cases of war-related trauma, represents a grave complication. The injuries sustained in war often entail severe damage to soft tissues, including significant impairment of vessels, nerves, tendons, muscles, and result in substantial bone defects. Complicating matters further, these infections often involve multidrug-resistant pathogens, making effective treatment a significant challenge. Optimal management of patients with combat-related trauma and signs of infection necessitates specialized care in dedicated centers. The approach to treatment should be guided by a well-defined algorithm that incorporates appropriate surgical interventions alongside systemic and localized antibiotic administration. In instances where chronic infection manifests after war-related injuries and specific causative agents are not definitively identified, initiating empiric therapy is advisable. A combination of meropenem, colistin, and vancomycin can be a suitable choice for initial treatment. Subsequently, once the causative microbes are identified, targeted treatment can be prescribed based on the susceptibility patterns. This article delves into the primary pathogens commonly found in war-related wounds and provides effective antibiotic regimens based on the specific microorganisms. One promising approach for managing severe war injuries is suppressive antibiotic therapy, which enhances the prospects of successful treatment. The comprehensive strategy outlinedhere aims to mitigate the serious risks posed by fracture-related infections in the context of war-induced trauma, ultimately improving patient outcomes and prognosis.

22 October 2026 in TRAUMA
Verified
Journal Article
Open access
Volodymyr FilipenkoVolodymyr Filipenko
Volodymyr Filipenko
SBS.YE. Bondarenko
S.YE. Bondarenko
YOYe.V. Olinkevich
Ye.V. Olinkevich
OMO.P. Marushchak
O.P. Marushchak
MKM.YU. Karpinsky
M.YU. Karpinsky
OYO.V. Yaresko
O.V. Yaresko
Background. Removal of a stable femoral component of a prosthesis is one of the most challenging problems in revision hip arthroplasty. An extended trochanteric osteotomy (ETO) provides adequate access to the femoral canal; however, once performed, the question arises as to the choice of length for the revision stem, which must cover the lower edge of the osteotomy without creating excessive stress concentrations in the bone and the fixation elements. The purpose was to conduct a comparative analysis of stress values in a femur model with a revision stem following an ETO, depending on the length of the stem. Materials and methods. A basic finite-element model of the femur was developed with a revision endoprosthesis implanted following an extended proximal osteotomy. Models were created for three variants of the endoprosthesis stem length: 1, 3 and 5 cm below the lower edge of the osteotomy. The bone flap was fixed with a 1.5-mm diameter cerclage wire at two levels, with two turns at each level. The model was loaded with a force of 1100 N applied to the femoral head and a force of 468 N from the hip abductors. Results. The length of the prosthesis stem has virtually no effect on the stress distribution in the bony elements of the models: at the distal end of the diaphysis and in the bone flap, the differences between the models are minimal. The most significant changes are observed in the area of the lower edge of the osteotomy, where, as the stem length increases from 1 to 5 cm, the stress level decreases from 18.9 to 13.0 MPa. Furthermore, a stem that overlaps the lower edge of the osteotomy by 5 cm results in the lowest stress levels in the endoprosthesis neck (148.9 MPa) and the cerclage wire (443.9 MPa); however, the stresses at its distal end increase 15-fold — to 217.7 MPa, which is, nevertheless, 2.5 times lower than the tensile strength of surgical steel. Conclusions. Covering the lower osteotomy zone with a revision stem by 5 cm following the removal of a stable femoral component using an ETO reduces the load on the cerclage wire and decreases stress concentration in the area of the lower edge of the osteotomy. This choice of stem length ensures component stability and offers advantages over the use of shorter revision stems, particularly in complex revision arthroplasty cases.

23 January 2019 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
PDF file
MKMykola Korzh
Mykola Korzh
VFVolodymyr Filipenko
Volodymyr Filipenko
FLFrieda Leontyeva
Frieda Leontyeva
OMOlexiy Marushchak
Olexiy Marushchak
NKNataliya Kuznetsova
Nataliya Kuznetsova
VDValentyna Dielievsks
Valentyna Dielievsks
The aim of the work was to reveal the parameters of immune response for prognosis of the early postoperative complications after knee and hip joint arthroplasty. Methods: there were 47 patients, aged 35–80 years with primary hip and knee arthritis after arthroplasty. 32 patients (1 group) had a favorable early postoperative course, 15 patients (2 group) had infectious complications. Level of autoimmune lymphocytotoxic (ALA) and granulocytotoxic antibodies (AGA), neutrophiles and lymphocytes, circulating immune complexes (CIC) were studied in synovial fluid and blood. The cell immune response was assessed in the test of leukocyte migration inhibition (LMIT) towards antigens of synovial membrane, bone and cartilage tissue, as well as towards bacterial antigens of Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus pyogenes, Clebsiella pneumoniae and Candida Lusitaniae. Results: the patients of the 2 group demonstrated lower level of neutrophiles in peripheral blood and higher one — in synovial fluid as compared to the patients of the 1 group. Neutrophile/lymphocyte ratio comprised 1.5 in the 2 group and 2.0 in the 1 group. Patients with infectious complications were characterized by the presence of ALA and higher level of AGA in the serum. ALA/AGA ratio in the 2 group comprised 1.5, in the 1 group — 2.0. The patients with infectious complications demonstrated higher level of ALA in synovial fluid (21.5 ± 0.92 %) and autoimmune origin of granulocytotoxic antibodies. Significant leukocyte migration towards synovial membrane and cartilage in LMIT was revealed in the patients of the 2 group before the surgery, that was associated with leukocyte migration enhancement towards those bacterial antigens, that were bacteriologically found in synovial fluid. Conclusions: lukocyte migration enhancement towards antigens of synovial membrane and joint tissue, as well as towards pathogenic bacteria along with the presence of ALA and increase of AGA in the serum and synovial fluid are considered as parameters of the complicated course of postoperative period after arthroplasty with a necessity of medical correction.