Ivana Komatina

Ivana Komatina

Auto-generated profile, based on publicly available information

Ivana Komatina

Vinca Institute of Nuclear Sciences - National Institute of Serbia, University of Belgrade, Belgrade, Serbia; Faculty of Physical Chemistry, University of Belgrade, Belgrade, Serbia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2024 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
MĐMiloš Đaletić
Miloš Đaletić
NKNikola Kržanović
Nikola Kržanović
VRVesna Radumilo
Vesna Radumilo
MŽMilos Živanović
Milos Živanović
IKIvana Komatina
Ivana Komatina

23 December 2025 in Physica Medica
Verified
Journal Article
Open access
NKNikola Kržanović
Nikola Kržanović
PTPaula Toroi
Paula Toroi
IKIvana Komatina
Ivana Komatina
BJBartel Jansen
Bartel Jansen
ABArgiro Boziari
Argiro Boziari
MŽMilos Živanović
Milos Živanović
X-ray medical imaging developments have introduced needs for updated dosimetry practices. Performance of commercially available dosimeters used for air kerma measurements in diagnostic and interventional radiology was examined. Ionization chambers and X-ray multimeters were tested in a wide range of air kerma rates, photon energies (using standard and non-standard radiation qualities), and angles of incidence with different dosimeter orientation and rotation. Stability and repeatability of the measured value, the influence of pulse duration, non-linearity of dosimeter response, energy and angular dependence were studied against the IEC 61674:2024 limits of variation. Energy response was tested using the standard RQR and RQT radiation qualities defined in IEC 61267:2005, as well as non-standard copper-filtered beams with added 0.9 mm Cu filtration. Most dosimeters complied with the IEC 61674:2024 standard limits of variation, for both standard and non-standard radiation fields. In some cases, observed performance was significantly better than the current limits allowing for the introduction of more stringent values. Modification of the performance requirements was proposed, considering differences between reference-class and field-class dosimeters, while introducing more stringent requirements for reference-class dosimeters.

30 December 2022 in Историјски часопис
Verified
Journal Article
Closed access
ИКИвана Коматина
Ивана Коматина
Рад је посвећен у српској науци контроверзном и веома значајном питању времена смрти првог српског архиепископа Светог Саве. Износи се и изнова оснажује претпоставка да је Свети Сава умро 14. јануара 1235. године. У складу са тим пружају се нова запажања о политичким приликама у Србији и Савином итинерару након што је напустио положај српског архиепископа.

29 July 2025 in Physica Medica
Verified
Journal Article
Open access
IKIvana Komatina
Ivana Komatina
VMVedrana Makarić
Vedrana Makarić
MŽMilos Živanović
Milos Živanović
PTPaula Toroi
Paula Toroi
ATAino Tietäväinen
Aino Tietäväinen
MKMika Kortesniemi
Mika Kortesniemi
Optimization and quality control of the diagnostic and interventional radiology procedures is usually performed with an X-ray multimeter (XMM) based on the non-invasive measurements of different X-ray tube and output parameters obtained from the X-ray beam, such as air kerma, tube voltage and half-value layer. Standardization and metrological support need to be improved, and harmonized calibration procedures are not available for all quantities. There is also a lack of data on performance of XMMs in different measurement conditions relevant for clinical practice. The needs for calibration of XMMs and current state of the art of calibration services were investigated by performing an overview of the standards, conducting surveys addressed to the clinical medical physicists and calibration laboratories and investigating the key comparison database. There are widely available calibration services for air kerma measurements for a large range of radiation qualities. However, there is a lack of calibration services for all other measured quantities, and very few laboratories besides the manufacturers are able to perform these calibrations. In addition, standardization gaps with non-harmonized calibration and measurement procedures for these quantities were found. New calibration services with harmonized procedures are needed for XMMs, especially for quantities beyond air kerma. There is a need to better understand and reduce measurement uncertainty for some quantities. New procedures will be developed within the TraMeXI project and disseminated to the standardization bodies, metrology and medical physics community.

12 March 2025 in Acta Antiqua Academiae Scientiarum Hungaricae
Verified
Journal Article
Closed access
PDF file
IKIvana Komatina
Ivana Komatina
The paper discusses the origin and use of the division into the “seven ages of man” in Serbian medieval hagiographies, with reference to data from diplomatic sources. Our intention is to examine the reliability of such a division and the time of its appearance in medieval Serbia, and to point out that the appearance of this concept in Serbian medieval hagiographies is a direct reception of ancient models.