Mika Kortesniemi

Mika Kortesniemi

Auto-generated profile, based on publicly available information

Mika Kortesniemi

HUS Diagnostic Center, Radiology, University of Helsinki and Helsinki University Hospital, Finland

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Physica Medica
Verified
Journal Article
Closed access
MKMika Kortesniemi
Mika Kortesniemi
VTVirginia Tsapaki
Virginia Tsapaki
ATAnnalisa Trianni
Annalisa Trianni
PRPaolo Russo
Paolo Russo
AMAd Maas
Ad Maas
JDJohn Damilakis
John Damilakis

24 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jan Sher AkmalJan Sher Akmal
Jan Sher Akmal
Mika SalmiMika Salmi
Mika Salmi
BHBjorn Hemming
Bjorn Hemming
LTLinus Teir
Linus Teir
ASAnni Suomalainen
Anni Suomalainen
ALAntti Lassila
Antti Lassila
In craniomaxillofacial surgical procedures, an emerging practice adopts the preoperative virtual planning that uses medical imaging (computed tomography), 3D thresholding (segmentation), 3D modeling (digital design), and additive manufacturing (3D printing) for the procurement of an end-use implant. The objective of this case study was to evaluate the cumulative spatial inaccuracies arising from each step of the process chain when various computed tomography protocols and thresholding values were independently changed. A custom-made quality assurance instrument (Phantom) was used to evaluate the medical imaging error. A sus domesticus (domestic pig) head was analyzed to determine the 3D thresholding error. The 3D modeling error was estimated from the computer-aided design software. Finally, the end-use implant was used to evaluate the additive manufacturing error. The results were verified using accurate measurement instruments and techniques. A worst-case cumulative error of 1.7 mm (3.0%) was estimated for one boundary condition and 2.3 mm (4.1%) for two boundary conditions considering the maximum length (56.9 mm) of the end-use implant. Uncertainty from the clinical imaging to the end-use implant was 0.8 mm (1.4%). This study helps practitioners establish and corroborate surgical practices that are within the bounds of an appropriate accuracy for clinical treatment and restoration.

6 June 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MKM Kortesniemi
M Kortesniemi
TKT Kiljunen
T Kiljunen
AKA Kangasmäki
A Kangasmäki
Multi-slice CT provides an efficient imaging modality for trauma imaging. The purpose of this study was to provide absorbed and effective dose data from CT taking into account the patient size and compare such doses with the standard CT dose quantities based on standard geometry. The CT examination data from abdominal and thoracic scan series were collected from 36 trauma patients. The CTDIvol, DLPw and effective dose were determined, and the influence of patient size was applied as a correction factor to calculated doses. The patient size was estimated from the patient weight as the effective radius based on the analysis from the axial images of abdominal and thoracic regions. The calculated mean CTDIvol, DLPw and effective dose were 15.2 mGy, 431 mGy cm and 6.5 mSv for the thorax scan, and 18.5 mGy, 893 mGy cm and 14.8 mSv for the abdomen scan, respectively. The doses in the thorax and abdomen scans taking the patient size into account were 34% and 9% larger than the standard dose quantities, respectively. The use of patient size in dose estimation is recommended in order to provide realistic data for evaluation of the radiation exposure in CT, especially for paediatric patients and smaller adults.

9 November 2024 in Physica Medica
Verified
Journal Article
Open access
JKJuuso H.J. Ketola
Juuso H.J. Ketola
SISatu I. Inkinen
Satu I. Inkinen
TMTeemu Mäkelä
Teemu Mäkelä
SSSuvi Syväranta
Suvi Syväranta
JPJuha Peltonen
Juha Peltonen
MKMika Kortesniemi
Mika Kortesniemi

25 June 2004 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
MKM Kortesniemi
M Kortesniemi
TST Seppälä
T Seppälä
IAI Auterinen
I Auterinen
SSS Savolainen
S Savolainen

2 October 2012 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
PTPaula Toroi
Paula Toroi
NKNiina Könönen
Niina Könönen
MTMarjut Timonen
Marjut Timonen
MKMika Kortesniemi
Mika Kortesniemi
The best compression paddle position during air kerma measurement in mammography dosimetry was studied. The amount of forward scattering as a function of the compression paddle distance was measured with different X-ray spectra and different types of paddles and dose meters. The contribution of forward scattering to the air kerma did not present significant dependency on the beam quality or of the compression paddle type. The tested dose meter types detected different amounts of forward scattering due to different internal collimation. When the paddle was adjusted to its maximum clinical distance, the proportion of the detected forward scattering was only 1 % for all dose meter types. The most consistent way of performing air kerma measurements is to position the compression paddle at the maximum distance from the dose meter and use a constant forward scattering factor for all dose meters. Thus, the dosimetric uncertainty due to the forward scatter can be minimised.