Tuomo Ylitalo

Tuomo Ylitalo

Auto-generated profile, based on publicly available information

Tuomo Ylitalo

Electronics Laboratory, Department of Physics, P.O. Box 64 (Gustaf Hällströmin katu 2a), University of Helsinki, FI-00014 Helsinki, Finland

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Osteoarthritis and Cartilage
Verified
Journal Article
Open access
HNHeikki Nieminen
Heikki Nieminen
TYT. Ylitalo
T. Ylitalo
SKSakari Karhula
Sakari Karhula
JSJussi Petteri Suuronen
Jussi Petteri Suuronen
SKS. Kauppinen
S. Kauppinen
SSSimo Saarakkala
Simo Saarakkala
Collagen distribution within articular cartilage (AC) is typically evaluated from histological sections, e.g., using collagen staining and light microscopy (LM). Unfortunately, all techniques based on histological sections are time-consuming, destructive, and without extraordinary effort, limited to two dimensions. This study investigates whether phosphotungstic acid (PTA) and phosphomolybdic acid (PMA), two collagen-specific markers and X-ray absorbers, could (1) produce contrast for AC X-ray imaging or (2) be used to detect collagen distribution within AC. We labeled equine AC samples with PTA or PMA and imaged them with micro-computed tomography (micro-CT) at pre-defined time points 0, 18, 36, 54, 72, 90, 180, 270 h during staining. The micro-CT image intensity was compared with collagen distributions obtained with a reference technique, i.e., Fourier-transform infrared imaging (FTIRI). The labeling time and contrast agent producing highest association (Pearson correlation, Bland-Altman analysis) between FTIRI collagen distribution and micro-CT -determined PTA distribution was selected for human AC. Both, PTA and PMA labeling permitted visualization of AC features using micro-CT in non-calcified cartilage. After labeling the samples for 36 h in PTA, the spatial distribution of X-ray attenuation correlated highly with the collagen distribution determined by FTIRI in both equine (mean ± S.D. of the Pearson correlation coefficients, r = 0.96 ± 0.03, n = 12) and human AC (r = 0.82 ± 0.15, n = 4). PTA-induced X-ray attenuation is a potential marker for non-destructive detection of AC collagen distributions in 3D. This approach opens new possibilities in development of non-destructive 3D histopathological techniques for characterization of OA.

1 October 2017 in Osteoarthritis and Cartilage
Verified
Journal Article
Open access
HNHeikki Nieminen
Heikki Nieminen
HGH.K. Gahunia
H.K. Gahunia
Kenneth PritzkerKenneth Pritzker
Kenneth Pritzker
TYT. Ylitalo
T. Ylitalo
LRL. Rieppo
L. Rieppo
SSSimo Saarakkala
Simo Saarakkala
Histopathological grading of osteochondral (OC) tissue is widely used in osteoarthritis (OA) research, and it is relatively common in post-surgery in vitro diagnostics. However, relying on thin tissue section, this approach includes a number of limitations, such as: (1) destructiveness, (2) sample processing artefacts, (3) 2D section does not represent spatial 3D structure and composition of the tissue, and (4) the final outcome is subjective. To overcome these limitations, we recently developed a contrast-enhanced μCT (CEμCT) imaging technique to visualize the collagenous extracellular matrix (ECM) of articular cartilage (AC). In the present study, we demonstrate that histopathological scoring of OC tissue from CEμCT is feasible. Moreover, we establish a new, semi-quantitative OA μCT grading system for OC tissue. Pathological features were clearly visualized in AC and subchondral bone (SB) with μCT and verified with histology, as demonstrated with image atlases. Comparison of histopathological grades (OARSI or severity (0-3)) across the characterization approaches, CEμCT and histology, excellent (0.92, 95% CI = [0.84, 0.96], n = 30) or fair (0.50, 95% CI = [0.16, 0.74], n = 27) intra-class correlations (ICC), respectively. A new μCT grading system was successfully established which achieved an excellent cross-method (μCT vs histology) reader-to-reader intra-class correlation (0.78, 95% CI = [0.58, 0.89], n = 27). We demonstrated that histopathological information relevant to OA can reliably be obtained from CEμCT images. This new grading system could be used as a reference for 3D imaging and analysis techniques intended for volumetric evaluation of OA pathology in research and clinical applications.

1 January 2019 in Osteoarthritis and Cartilage
Verified
Journal Article
Open access
SKS. Kauppinen
S. Kauppinen
SKSakari Karhula
Sakari Karhula
JTjerome thevenot
jerome thevenot
TYT. Ylitalo
T. Ylitalo
LRL. Rieppo
L. Rieppo
HNHeikki Nieminen
Heikki Nieminen
Our aim is to establish methods for quantifying morphometric properties of calcified cartilage (CC) from micro-computed tomography (μCT). Furthermore, we evaluated the feasibility of these methods in investigating relationships between osteoarthritis (OA), tidemark surface morphology and open subchondral channels (OSCCs). Samples (n = 15) used in this study were harvested from human lateral tibial plateau (n = 8). Conventional roughness and parameters assessing local 3-dimensional (3D) surface variations were used to quantify the surface morphology of the CC. Subchondral channel properties (percentage, density, size) were also calculated. As a reference, histological sections were evaluated using Histopathological osteoarthritis grading (OARSI) and thickness of CC and subchondral bone (SCB) was quantified. OARSI grade correlated with a decrease in local 3D variations of the tidemark surface (amount of different surface patterns (rs = -0.600, P = 0.018), entropy of patterns (EP) (rs = -0.648, P = 0.018), homogeneity index (HI) (rs = 0.555, P = 0.032)) and tidemark roughness (TMR) (rs = -0.579, P = 0.024). Amount of different patterns (ADP) and EP associated with channel area fraction (CAF) (rp = 0.876, P < 0.0001; rp = 0.665, P = 0.007, respectively) and channel density (CD) (rp = 0.680, P = 0.011; rp = 0.582, P = 0.023, respectively). TMR was associated with CAF (rp = 0.926, P < 0.0001) and average channel size (rp = 0.574, P = 0.025). CC topography differed statistically significantly in early OA vs healthy samples. We introduced a μ-CT image method to quantify 3D CC topography and perforations through CC. CC topography was associated with OARSI grade and OSCC properties; this suggests that the established methods can detect topographical changes in tidemark and CC perforations associated with OA.

1 February 2014 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
UPUrve Paaver
Urve Paaver
Jyrki HeinämäkiJyrki Heinämäki
Jyrki Heinämäki
IKIvan Kassamakov
Ivan Kassamakov
EHEdward Hæggström
Edward Hæggström
TYTuomo Ylitalo
Tuomo Ylitalo
PVPeep Veski
Peep Veski

24 September 2019 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
UPUrve Paaver
Urve Paaver
Jyrki HeinämäkiJyrki Heinämäki
Jyrki Heinämäki
IKIvan Kassamakov
Ivan Kassamakov
TYTuomo Ylitalo
Tuomo Ylitalo
EHEdward Hæggström
Edward Hæggström
Karin KogermannKarin Kogermann
Karin Kogermann
We investigated and monitored in situ the wetting and dissolution properties of polymeric nanofibers and determined the solid-state of a drug during dissolution. Piroxicam (PRX) was used as a low-dose and poorly-soluble model drug, and hydroxypropyl methylcellulose (HPMC) and polydextrose (PD) were used as carrier polymers for electrospinning (ES). The initial-stage dissolution of the nanofibers was monitored in situ with three-dimensional white light microscopic interferometry (SWLI) and high-resolution optical microscopy. The physical solid-state characterization of nanofibers was performed with Raman spectroscopy, X-ray powder diffraction (XRPD), and scanning electron microscopy (SEM). We showed that PRX recrystallizes in a microcrystalline form immediately after wetting of nanofibers, which could lead to enhanced dissolution of drug. Initiation of crystal formation was detected by SWLI, indicating: (1) that PRX was partially released from the nanofibers, and (2) that the solid-state form of PRX changed from amorphous to crystalline. The amount, shape, and size of the PRX crystals depended on the carrier polymer used in the nanofibers and dissolution media (pH). In conclusion, the present nanofibers loaded with PRX exhibit a quasi-dynamic dissolution via recrystallization. SWLI enables a rapid, non-contacting, and non-destructive method for in situ monitoring the early-stage dissolution of nanofibers and regional mapping of crystalline changes (re-crystallization) during wetting. Such analysis is crucial because the wetting and dissolution of nanofibers can greatly influence the performance of nanofibrous drug delivery systems in pharmaceutical and biomedical applications.

26 April 2012
Verified
Conference Paper
Closed access
ANA. Nolvi
A. Nolvi
VHV. Heikkinen
V. Heikkinen
IKI. Kassamakov
I. Kassamakov
JAJ. Aaltonen
J. Aaltonen
TYT. Ylitalo
T. Ylitalo
EHE. Hæggström
E. Hæggström
LED based infrared scanning white light interferometry (IR-SWLI) permits non-destructive imaging of embedded MEMS structures. We built an IR-SWLI instrument featuring a custom-built IR-range LED-based light source, capable of stroboscopic use. The source combines multiple separately controllable LEDs with different wavelengths into a collimated homogenous beam offering an adjustable spectrum. We employ software-based image stitching to form millimeter-size 3D images from multiple high magnification scans. These images delineate three layers in a MEMS cavity covered by silicon and reveal a micron-size inlet inside the channel.