Enhancement of trace gas detectability using photoacoustic spectroscopy requires the effective suppression of strong background noise for practical applications. An upgraded infrared broadband trace gas detection configuration was investigated based on a Fourier transform infrared (FTIR) spectrometer equipped with specially designed T-resonators and simultaneous differential optical and photoacoustic measurement capabilities. By using acetylene and local air as appropriate samples, the detectivity of the differential photoacoustic mode was demonstrated to be far better than the pure optical approach both theoretically and experimentally, due to the effectiveness of light-correlated coherent noise suppression of non-intrinsic optical baseline signals. The wavelet domain denoising algorithm with the optimized parameters was introduced in detail to greatly improve the signal-to-noise ratio by denoising the incoherent ambient interference with respect to the differential photoacoustic measurement. The results showed enhancement of sensitivity to acetylene from 5 ppmv (original differential mode) to 806 ppbv, a fivefold improvement. With the suppression of background noise accomplished by the optimized wavelet domain denoising algorithm, the broadband differential photoacoustic trace gas detection was shown to be an effective approach for trace gas detection.
We present a sensitive and compact quantum cascade laser-based photoacoustic greenhouse gas sensor for the detection of CO2, CH4 and CO and discuss its applicability toward on-line real-time trace greenhouse gas analysis. Differential photoacoustic resonators with different dimensions were used and optimized to balance sensitivity with signal saturation. The effects of ambient parameters, gas flow rate, pressure and humidity on the photoacoustic signal and the spectral cross-interference were investigated. Thanks to the combined operation of in-house designed laser control and lock-in amplifier, the gas detection sensitivities achieved were 5.6 ppb for CH4, 0.8 ppb for CO and 17.2 ppb for CO2, signal averaging time 1 s and an excellent dynamic range beyond 6 orders of magnitude. A continuous outdoor five-day test was performed in an observation station in China’s Qinling National Botanical Garden (E longitude 108°29’, N latitude 33°43’) which demonstrated the stability and reliability of the greenhouse gas sensor.
The existence of a signal baseline due to a variety of reasons in a photoacoustic (PA) gas measurement system is a common phenomenon. One major component is the absorption of optical windows in an enclosed PA cell. This work explores the relation between the background signal and the thermoelastic effect inside the windows by modelling the pressure and elastic wave field by means of a Green-function based method. The influence of laser incidence location, angle and radius is discussed based on a rigorous three-dimensional solid-to-fluid coupling model. The effects were theoretically demonstrated culminating in the determination of best (minimum background signal) performance using a collimated and expanded incident laser beam. The results were also validated through experiments.
18 March 2022 in Microwave and Optical Technology Letters