Xing Chen

Xing Chen

Auto-generated profile, based on publicly available information

Xing Chen

Tongji Univ

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in International Journal of Impact Engineering
Verified
Journal Article
Closed access
XCXing Chen
Xing Chen
Suwen ChenSuwen Chen
Suwen Chen
GLGuo-Qiang Li
Guo-Qiang Li

18 July 2023 in Composite Structures
Verified
Journal Article
Closed access
XCXing Chen
Xing Chen
BLBinbin Lin
Binbin Lin
MSMiriam Schuster
Miriam Schuster
Suwen ChenSuwen Chen
Suwen Chen
BXBai-Xiang Xu
Bai-Xiang Xu
JSJens Schneider
Jens Schneider

1 June 2012
Verified
Conference Paper
Closed access
Gary BoneGary Bone
Gary Bone
XCXing Chen
Xing Chen
The design, modeling and control of a novel hybrid pneumatic-electric actuator for applications in robotics and automation is presented. The design incorporates a pneumatic cylinder and DC motor connected in parallel. By avoiding the need for a high ratio transmission, the design greatly reduces the joint friction torque that contributes to the danger associated with robot arms. A novel discrete-valued model-predictive control (DVMPC) algorithm is proposed for controlling the position of the pneumatic cylinder with on/off valves, rather than costly proportional or servo valves. A variant of inverse dynamics control is proposed for the DC motor. A prototype was built for validating the actuator design and control algorithms. It is used to rotate a single-link robot arm. Experimental results are presented for vertical cycloidal and sinusoidal position trajectories. Even with the poor quantization caused by the on/off valves, the pneumatic cylinder controlled by the proposed DVMPC algorithm achieved a 2.5% maximum absolute error (MAE) for the vertical cycloidal trajectory. The DVMPC algorithm also switches the valves less often than the PWM method, reducing valve wear. With the addition of the DC motor to form the hybrid actuator, the performance improvement was significant. For the vertical cycloidal trajectory, the MAE was reduced to 0.37%. With the vertical sinusoidal trajectory, the MAE was 1.1%. These results compare favorably to the 5% MAE achieved by previous researchers for a horizontal sinusoidal trajectory using a hybrid pneumatic-electric actuator controlled by servo valves.

1 January 2023 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
XCXing Chen
Xing Chen
Suwen ChenSuwen Chen
Suwen Chen
YZYukuan Zhang
Yukuan Zhang
ZWZhongqi Wang
Zhongqi Wang
Novel ionomer-laminated glass is popularly adopted as facades or structural elements due to its optical clarity and excellent load-bearing capacity. To better understand the behavior and failure mechanism of ionomer-laminated glass subjected to blast loading, a systematic study, including field blast tests, nonlinear dynamic numerical analysis, and pressure–impulse (P-I) analysis, was carried out. First, a series of full-scale field blast tests were conducted on 1,300  m×1,600  m×13.52  mm framed ionomer-laminated glass to investigate the precracking and postcracking responses as well as the failure mode of ionomer-laminated glass subjected to different explosions. The out-of-plane deflection fields over the panel surface were captured using the three-dimensional digital image correlation (3D-DIC) technique. A 3D solid finite-element (FE) model was developed using LS-DYNA for simulating the dynamic response of blast-loaded ionomer-laminated glass. The numerical results were compared with the test results for validation, which shows that the built model can reproduce the response of framed ionomer-laminated glass in both precracking and postcracking phases well. In addition, a P-I analysis was carried out for characterization of the influence of negative blast pressure over a wide range of blast threats. It was found that the negative blast pressure has a significant impact on the glass crack limit when the natural period of the laminated glass is in the same scale as the duration of the blast load, and an obvious influencing zone with the td/T ratio between 0.1 and 1 can be identified. The negative blast pressure has a similar influence on the interlayer rupture limit. Rebounding failure is highly likely to occur when the laminated glass is subjected to blast threats in the influencing zone. Neglecting the negative phase may result in overestimations of the blast resistance of ionomer-laminated glass at both damage levels.


1 June 2025 in Engineering Structures
Verified
Journal Article
Closed access
YHYang Huang
Yang Huang
Suwen ChenSuwen Chen
Suwen Chen
XCXing Chen
Xing Chen