Juan Yan

Juan Yan

Auto-generated profile, based on publicly available information

Juan Yan

Chongqing University of Posts and Telecommunications

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TFTao Feng
Tao Feng
JYJuan Yan
Juan Yan
LLLei Liu
Lei Liu
YHYujia Huo
Yujia Huo
IKIgor Konyakhin
Igor Konyakhin
RLRenpu Li
Renpu Li
A calibration and measurement method based on an autocollimator and a manual turntable are proposed to calibrate the mounting error of a three-axis microelectromechanical system (MEMS) gyroscope in a wearable inertial measurement unit (IMU). In this system, with extension of the angle range of the autocollimator to ±9° and setting the mutual orthogonal structure of the two autocollimators, the measurement angle range of the MEMS gyroscope mounting error and the evaluation reference of the three-axis attitude angle data are obtained respectively, and the common data acquisition serial port between the autocollimator camera and the IMU host computer is built. As a result, the acquisition time is synchronized between the two systems. Additionally, the angular rate reading value of the MEMS gyroscope is integrated by time to unify the reading value scale between the calibration system and the MEMS gyroscope. This method is further compared with the traditional precision three-axis angular rate output turntable calibration method, and the accuracy deviation of the MEMS gyroscope mounting error after calibration is less than 0.3%. This method helps facilitate the development of inertial sensing calibration techniques toward traceability, which significantly reduces and simplifies laboratory equipment costs and maintenance requirements.

13 December 2024 in Optics Express
Verified
Journal Article
Closed access
RLRenpu Li
Renpu Li
JYJuan Yan
Juan Yan
JCJiwen Cui
Jiwen Cui
JGJunqi Guo
Junqi Guo
AKAndrei Kulikov
Andrei Kulikov
DWDandan Wen
Dandan Wen
As a benchmark apparatus for small-angle precision measurements, enhancing the measurement accuracy of autocollimators has always been a focal point of industry attention. However, there are currently no reports on the investigation of the impact that internal aperture processing quality has on measurement precision and accuracy. This paper integrates the general Hough transform image recognition and localization algorithm to analyze the mechanisms inducing measurement uncertainty and error in autocollimators caused by defects in the optical stop aperture. A method utilizing femtosecond laser (FSL) processing of the crosshair aperture is proposed to compensate for the traditional optical stop aperture roughness. Compared to conventional machining, this method reduces the autocollimator measurement uncertainty by 31.6% and 48.1% in the yaw and pitch angle directions, respectively, and decreases the measurement root mean square (RMS) error by 35.9% and 41.8%, respectively.