10 July 2026 in Insights into Imaging
Objectives: To assess inter-rater agreement and diagnostic performance of six United States National Institute for Occupational Safety and Health-certified B readers (physicians certified in standardized chest X-ray (CXR) classification for pneumoconiosis) in diagnosing tuberculosis (TB) on CXR, with the goal of developing a reliable dataset to support external validation of artificial intelligence (AI) models for TB detection. Materials and methods: 1097 CXRs from five institutions were analyzed by six B readers. Patients aged ≥ 15 years were included, excluding those with HIV or opportunistic infections. CXRs were classified as unremarkable or abnormal. Abnormalities were categorized using a modified International Labor Organization classification and classified as consistent or inconsistent with TB. Microbiological references included sputum smears, cultures, or molecular tests. Descriptive statistics summarized the CXR and microbiological findings. Inter-rater agreement was assessed with Fleiss’ kappa. Diagnostic performance was evaluated by comparing CXR findings to microbiological references. Results: Of the 3117 readings, 69% of CXRs were abnormal, and 31% were unremarkable. Microbiological results confirmed that 87% of abnormal CXRs were TB cases, while 83% of unremarkable CXRs were non-TB. Inter-rater agreements were κ = 0.83 for all findings, κ = 0.67 for findings consistent with TB, and κ = 0.76 for active TB findings. For findings consistent with TB, the sensitivity, specificity, and accuracy ranged from 77.2% to 91.1%, 87.4% to 98.6%, and 84.1% to 90.1%, respectively. Conclusion: B readers exhibited strong agreement and high accuracy in diagnosing TB on CXR, providing a robust dataset that could be used for external validation of AI models in TB diagnosis. Critical relevance statement: With substantial inter-rater agreement and strong diagnostic performance, B readers’ interpretations of CXRs provide a reliable dataset to support external validation of AI models for TB diagnosis. Key Points: B readers can provide a reliable reference for validating AI models in TB diagnosis. Less variability and high accuracy were observed among B readers in CXR-based TB diagnosis.
2 October 2026 in Clinical Critical Care
Background: Massive pulmonary embolism (PE) remains a leading cause of preventable perioperative mortality after bariatric surgery. Cardiopulmonary resuscitation (CPR) is challenging in patients with extreme obesity, and extracorporeal cardiopulmonary resuscitation (ECPR) is increasingly used as a salvage therapy. Case Presentation: A 60-year-old woman with super-super obesity (body weight: 142 kg; body mass index [BMI]: 61 kg/m2) suffered pulseless electrical activity (PEA) cardiac arrest on postoperative day (POD) 3 following elective robotic Roux-en-Y gastric bypass. Management: ECPR was initiated using veno-arterial extracorporeal membrane oxygenation (VA-ECMO). Cannulation was difficult due to her extreme body habitus, resulting in a prolonged low-flow time of 85 minutes to reach target flow. Bedside echocardiography and pulmonary artery catheterization confirmed massive obstructive shock. Thrombolysis was deferred due to bleeding risks from the fresh bariatric incision, and she was successfully managed with conservative anticoagulation. Her ICU course was complicated by new-onset atrial fibrillation, septic shock, and Harlequin syndrome, all of which were successfully resolved. Outcome: Although cardiopulmonary function recovered and follow-up computed tomographic pulmonary angiography showed complete thrombus resolution, she sustained severe hypoxic–ischemic encephalopathy (HIE) and died one year later. Conclusion: Standardized adherence to combined mechanical and pharmacologic venous thromboembolism (VTE) prophylaxis is essential in patients with super-super obesity. While ECPR can restore systemic circulation, technical challenges can prolong low-flow time and compromise neurological outcomes.