Ony Asrarul Qudsi

Ony Asrarul Qudsi

Auto-generated profile, based on publicly available information

Ony Asrarul Qudsi

Politeknik Elektronika Negeri Surabaya

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2017 in EMITTER International Journal of Engineering Technology
Verified
Journal Article
Open access
PDF file
LRLucky Pradigta Setiya Raharja
Lucky Pradigta Setiya Raharja
OQOny Asrarul Q.
Ony Asrarul Q.
ZAZainal Arief
Zainal Arief
NWNovie Ayub Windarko
Novie Ayub Windarko
In this research, modified PWM has been applied to the multilevel inverter (MLI) single-phase three-level diode clamp full bridge. Modified PWM is performed to produce minimum Total Harmonic Distortion (THD) the voltage because the quality of the good voltage is indicated by small THD. The THD indicates the quality of AC voltage source. The THD standard by the IEEE STD 519-1992 Harmonic Voltage Limits is 5% and the Pacific Corp standard is 8%, if the THD value is greater than the THD standard it can cause the electronic load to be damaged due to the damaged waveform. Modified PWM is applied by adding a 50 Hz sinusoidal reference signal with a sinusoidal signal which has a certain amplitude, frequency and phase shift angle. The frequency of the adder signal is the frequency at which the value of the individual harmonic voltage appears (n harmonic). To get maximum result, optimization using Genetic Algorithm (GA) method to determinate amplitude & phase shift angle done. The result of implementation hardware with modified PWM shows smaller THD voltage compared to the THD voltage with Sinusoidal Pulse Width Modulation (SPWM) switching up to 0.19 or decrease 65,51 % for modified PWM of harmonic injection n = 7 with GA optimization ma= 0.8 (A=0.0936 and ø = 0 rad) and up to 0.08 or decrease 12,30 % for modified PWM of harmonic injection n = 22 with GA optimization ma = 0.4 (A=0.1221 and ø = 0 rad).

1 November 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
ESEpyk Sunarno
Epyk Sunarno
ISIndhana Sudiharto
Indhana Sudiharto
SNSyechu Dwitya Nugraha
Syechu Dwitya Nugraha
FMFarid Dwi Murdianto
Farid Dwi Murdianto
SUSuryono
Suryono
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
The electrical energy has been dependent on fossil fuels, but the availability of fossil energy is running low with increasing electricity demand in society. Therefore a lot of research is done on renewable energy sources, one of which is solar energy. Solar energy can be applied to home scale DC microgrid systems. In the DC microgrid system the independent source of energy for the supply of loads comes from two sources, namely DC bus and 120 volt battery. To combine these two energy sources, a bidirectional converter is needed which will regulate power flow and electricity storage. In this system the battery can become a burden and can be a source of energy in the same series. Bidirectional converters can work in two directions, namely charging mode and discharging mode. The type of converter used in this bidirectional converter is SEPIC/ZETA Converter. The use of this type of converter is expected to reduce the ripple at the output voltage and minimize voltage disturbances during switching. The control method used is a fuzzy logic controller for voltage control which is expected to produce stable output.

8 August 2018 in INOVTEK POLBENG
Verified
Journal Article
Open access
PDF file
SNSyechu Dwitya Nugraha
Syechu Dwitya Nugraha
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
DYDiah Septi Yanaratri
Diah Septi Yanaratri
Aplikasi dari pemanfaatan energi matahari adalah sebuah mikrogrid skala rumah. Pada mikrogrid khususnya menggunakan panel surya atau photovoltaic (PV) sebagai sumber energi utama. Pada aplikasinya tegangan keluaran dari PV dinaikkan atau diturunkan dengan DC-DC konverter. Akan tetapi permasalahan yang terjadi adalah daya atau tegangan keluaran dari PV mudah berubah terhadap irradiasi matahari sehingga perlu dinaikkan dengan rating kelipatan tegangan yang tinggi mencapai 400 V untuk suplai DC bus bar. Maka dari itu pada penelitian ini akan mengaplikasikan Current Fed Push Pull Converter dengan menggunakan kontrol PI yang dapat menaikkan tegangan masukan yang bernilai 70V - 95 V menjadi 400 V dan distabilkan menggunakan metode PI. Dari hasil implementasi, sistem mampu menaikkan tegangan keluaran 400 V dan menjaga tegangan tersebut tetap stabil walaupun tegangan masukannya berubah-ubah

22 November 2018 in Jurnal Nasional Teknik Elektro dan Teknologi Informasi
Verified
Journal Article
Open access
PDF file
APAditya Ilham Pradana
Aditya Ilham Pradana
EPEka Prasetyono
Eka Prasetyono
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
EPEra Purwanto
Era Purwanto
SSSutedjo Sutedjo
Sutedjo Sutedjo
DYDiah Septi Y.
Diah Septi Y.
Manajemen dan Pemantauan Energi Motor BLDC pada Mobil Listrik Berbasis IoT