Yves Petremand

Yves Petremand

Auto-generated profile, based on publicly available information

Yves Petremand

Micro Nano Systems, CSEM SA, Neuchtel, Switzerland

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
LTLoïc Tissot-Daguette
Loïc Tissot-Daguette
FCFlorent Cosandier
Florent Cosandier
QGQuentin Gubler
Quentin Gubler
YPYves Pétremand
Yves Pétremand
MDMichel Despont
Michel Despont
SHSimon Henein
Simon Henein
Residual stresses can be advantageously used to permanently preload flexure micro-mechanisms in order to modify their deflection and stiffness. This paper presents a new preloading chevron mechanism (PCM) used to amplify the preloading effect of thin film residual stress. To evaluate the preloading performances of this structure, the deflection characteristics of buckled beams and flexure linear stages preloaded by a PCM is investigated experimentally. All the mechanisms are manufactured from a monocrystalline silicon substrate using deep reactive ion etching and residual stress is provided by wet thermal oxidation. Measurements show that the deflection magnitude of fixed-fixed oxidized silicon buckled beams can be increased by up to 5 times when a PCM is integrated. The flexure linear stages studied in this research are composed of a parallel leaf spring stage connected to two fixed-guided buckled beams preloaded by a PCM. Depending on the beam dimensions, the stage translational stiffness can be set to a specific value. We designed a near-zero positive stiffness linear stage revealing a measured stiffness reduction of 98%, and a bistable linear stage with a constant negative stiffness region. Thanks to the elevated preloading displacement supplied by the PCM, the operating stroke (actuation region where the stiffness remains constant) is relatively large (more than 0.4 mm travel for 2.59 mm leaf spring length). The analytical and numerical models carried out to design the mechanisms are in good agreement with the experimental data. The results show that the fixed frame stiffness has a significant effect on the preloading performances due to the substantial forces exerted by the PCM. Furthermore, the presented preloading concept, modeling and sizing method could be applied to other compliant mechanism designs, scales and materials, enabling applications in microelectromechanical systems and watchmaking.

19 February 2025 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
EGEnrico Gasparin
Enrico Gasparin
AHArno Hoogerwerf
Arno Hoogerwerf
DBDara Bayat
Dara Bayat
GDGuido Spinola Durante
Guido Spinola Durante
YPYves Petremand
Yves Petremand
GCGael Close
Gael Close
Magnetic sensors are often used near current-carrying wires or electrical motors generating significant magnetic interference. To mitigate the effects of these stray fields, the traditional design approach relies on a differential sensing scheme: multiple magnetometers are spaced apart, and the field differences are measured. Despite being rejected, stray fields still constrain the design space. Extra linear range and matched channels are required to accommodate their peak amplitude without saturation or residual common-mode leakage. On the contrary, single-point MEMS gradiometers rely on the force acting on a magnet, which is directly proportional to the magnetic field gradient. The stray field is intrinsically rejected by the magnetic transducing mechanism, even before entering the measurement chain. The range of the measurement chain can then be largely optimized for the gradient, independently of the stray field amplitude. This paper discusses the design of a single-point MEMS gradiometer. By design, it rejects magnetic stray fields and mechanical disturbances like vibrations and gravity. It is the first single-point MEMS gradiometer capable of operating unshielded and in various orientations. The prototype achieves a noise density of 4 nT/mm/ Hz within a measurement range of ± 300 μ T/mm. The paper demonstrates the sensorfs effectiveness in a bus-bar current sensing application. Design limitations and future design prospects are also outlined.