7 February 2022 in NeuroImage
RNRavi Prakash Reddy Nanga
+6
In the technique presented here, dubbed ‘qMRS’, we quantify the change in 1H MRS signal following administration of 2H-labeled glucose. As in recent human DMRS studies, we administer [6,6′−2H2]-glucose orally to healthy subjects. Since 2H is not detectable by 1H MRS, the transfer of the 2H label from glucose to a downstream metabolite leads to a reduction in the corresponding 1H MRS resonance of the metabolite, even if the total concentration of both isoforms remains constant. Moreover, introduction of the deuterium label alters the splitting pattern of the proton resonances, making indirect detection of the deuterated forms– as well as the direct detection of the decrease in unlabeled form– possible even without a 2H coil. Because qMRS requires only standard 1H MRS acquisition methods, it can be performed using commonly implemented single voxel spectroscopy (SVS) and chemical shift imaging (CSI) sequences. In this work, we implement qMRS in semi-LASER based CSI, generating dynamic maps arising from the fitted spectra, and demonstrating the feasibility of using qMRS and qCSI to monitor dynamic metabolism in the human brain using a 7T scanner with no auxiliary hardware.
25 August 2022 in Magnetic Resonance in Medicine
23 July 2024 in Magnetic Resonance in Medicine
Purpose: The purpose of this study was to determine the effect of acute nicotinamide riboside (NR) supplementation on cerebral nicotinamide adenine dinucleotide (NAD+) levels in the human brain in vivo by means of downfield proton MRS (DF 1H MRS).Methods: DF 1H MRS was performed on 10 healthy volunteers in a 7.0 T MRI scanner with spectrally selective excitation and spatially selective localization to determine cerebral NAD+ levels on two back‐to‐back days: once after an overnight fast (baseline) and once 4 h after oral ingestion of nicotinamide riboside (900 mg). Additionally, two more baseline scans were performed following the same paradigm to assess test–retest reliability of the NAD+ levels in the absence of NR.Results: NR supplementation increased mean NAD+ concentration compared to the baseline (0.458 ± 0.053 vs. 0.392 ± 0.058 mM; p < 0.001). The additional two baseline scans demonstrated no differences in mean NAD+ concentrations (0.425 ± 0.118 vs. 0.405 ± 0.082 mM; p = 0.45), and no difference from the first baseline scan (F(2, 16) = 0.907; p = 0.424).Conclusion: These preliminary results confirm that acute NR supplementation increases cerebral NAD+ levels in healthy human volunteers and shows the promise of DF 1H MRS utility for robust detection of NAD+ in humans in vivo.
9 September 2024 in Magnetic Resonance in Medicine
Purpose: This goal of this study was to optimize spectrally selective 1H‐MRS methods for large‐volume acquisition of low‐concentration metabolites with downfield resonances at 7 T and 3 T, with particular attention paid to detection of nicotinamide adenine dinucleotide (NAD+) and tryptophan.Methods: Spectrally selective excitation was used to avoid magnetization‐transfer effects with water, and various sinc pulses were compared with a band‐selective, uniform response, pure‐phase (E‐BURP) pulse. Localization using a single‐slice selective pulse was compared with voxel‐based localization that used three orthogonal refocusing pulses, and low bandwidth refocusing pulses were used to take advantage of the chemical shift displacement of water. A technique for water sideband removal was added, and a method of coil channel combination for large volumes was introduced.Results: Proposed methods were compared qualitatively with previously reported techniques at 7 T. Sinc pulses resulted in reduced water signal excitation and improved spectral quality, with a symmetric, low bandwidth‐time product pulse performing best. Single‐slice localization allowed shorter TEs with large volumes, enhancing signal, whereas low‐bandwidth slice‐selective localization greatly reduced the observed water signal. Gradient cycling helped remove water sidebands, and frequency aligning and pruning individual channels narrowed spectral linewidths. High‐quality brain spectra of NAD+ and tryptophan are shown in 4 subjects at 3 T.Conclusion: Improved spectral quality with higher downfield signal, shorter TE, lower nuisance signal, reduced artifacts, and narrower peaks was realized at 7 T. These methodological improvements allowed for previously unachievable detection of NAD+ and tryptophan in human brain at 3 T in under 5 min.
1 May 2023 in Magnetic Resonance in Medicine
18 February 2023 in Magnetic Resonance in Medicine