Michael Ryan Kann

Michael Ryan Kann

Auto-generated profile, based on publicly available information

Michael Ryan Kann

University of Pittsburgh School of Medicine, Pittsburgh, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in The Spine Journal
Verified
Journal Article
Open access
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
KBKarma Barot
Karma Barot
SBSamuel Brehm
Samuel Brehm
TBTim Bui
Tim Bui
KJKaran Joseph Karan Joseph
Karan Joseph Karan Joseph
CMCamilo A. Molina
Camilo A. Molina
The accurate and safe positioning of cervical pedicle screws is crucial. While augmented reality (AR) use in spine surgery has previously demonstrated clinical utility in the thoracolumbar spine, its technical feasibility in the cervical spine remains less explored. The objective of this study was to assess the precision and safety of AR-assisted pedicle screw placement in the cervical spine. In this experimental study, five cadaveric cervical spine models were instrumented from C3 to C7 by five different spine surgeons. The navigation accuracy and clinical screw accuracy were evaluated. Post-procedural CT scans were evaluated for clinical accuracy by two independent neuroradiologists using the Gertzbein-Robbins scale. Technical precision was assessed by calculating the angular trajectory (°) and linear screw tip (mm) deviations in the axial and sagittal planes from the virtual pedicle screw position as recorded by the AR-guided platform during the procedure compared to the actual pedicle screw position derived from post-procedural imaging. A total of forty-one pedicle screws were placed in five cervical cadavers, with each of the five surgeons navigating at least seven screws. Gertzbein-Robbins grade of A or B was achieved in 100% of cases. The mean values for tip and trajectory errors in the axial and sagittal planes between the virtual versus actual position of the screws was less than 3 mm and 30°, respectively (p<0.05). None of the cervical screws violated the cortex by more than 2 mm or displaced neurovascular structures. AR-assisted cervical pedicle screw placement in cadavers demonstrated clinical accuracy comparable to existing literature values for image-guided navigation methods for the cervical spine. This study provides technical and clinical accuracy data that supports clinical trialing of AR-assisted subaxial cervical pedicle screw placement.

7 August 2024 in Medical Science Educator
Verified
Journal Article
Closed access
PDF file
MKMichael R. Kann
Michael R. Kann
GHGrace W. Huang
Grace W. Huang
SPSangami Pugazenthi
Sangami Pugazenthi
RKRachel Kann
Rachel Kann
DCDavid Chen
David Chen
NZNichole Zehnder
Nichole Zehnder

6 February 2024 in Medicina
Verified
Journal Article
Open access
PDF file
MKMichael Ryan Kann
Michael Ryan Kann
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
SBSamuel Brehm
Samuel Brehm
TBTim Bui
Tim Bui
KJKaran Joseph Karan Joseph
Karan Joseph Karan Joseph
CMCamilo A. Molina
Camilo A. Molina
Background and Objectives: Augmented reality head-mounted display (AR-HMD) is a novel technology that provides surgeons with a real-time CT-guided 3-dimensional recapitulation of a patient’s spinal anatomy. In this case series, we explore the use of AR-HMD alongside more traditional robotic assistance in surgical spine trauma cases to determine their effect on operative costs and perioperative outcomes. Materials and Methods: We retrospectively reviewed trauma patients who underwent pedicle screw placement surgery guided by AR-HMD or robotic-assisted platforms at an academic tertiary care center between 1 January 2021 and 31 December 2022. Outcome distributions were compared using the Mann–Whitney U test. Results: The AR cohort (n = 9) had a mean age of 66 years, BMI of 29.4 kg/m2, Charlson Comorbidity Index (CCI) of 4.1, and Surgical Invasiveness Index (SII) of 8.8. In total, 77 pedicle screws were placed in this cohort. Intra-operatively, there was a mean blood loss of 378 mL, 0.78 units transfused, 398 min spent in the operating room, and a 20-day LOS. The robotic cohort (n = 13) had a mean age of 56 years, BMI of 27.1 kg/m2, CCI of 3.8, and SII of 14.2. In total, 128 pedicle screws were placed in this cohort. Intra-operatively, there was a mean blood loss of 432 mL, 0.46 units transfused units used, 331 min spent in the operating room, and a 10.4-day LOS. No significant difference was found between the two cohorts in any outcome metrics. Conclusions: Although the need to address urgent spinal conditions poses a significant challenge to the implementation of innovative technologies in spine surgery, this study represents an initial effort to show that AR-HMD can yield comparable outcomes to traditional robotic surgical techniques. Moreover, it highlights the potential for AR-HMD to be readily integrated into Level 1 trauma centers without requiring extensive modifications or adjustments.

7 January 2025 in Journal of Surgical Research
Verified
Journal Article
Closed access
MKMichael R. Kann
Michael R. Kann
EEEmily Estes
Emily Estes
SPSangami Pugazenthi
Sangami Pugazenthi
ABAwinita Barpujari
Awinita Barpujari
VMVamsi Mohan
Vamsi Mohan
CGChristopher S Graffeo
Christopher S Graffeo

1 August 2024 in Global Spine Journal
Verified
Journal Article
Open access
KBKarma Barot
Karma Barot
MRMiguel A Ruiz-Cardozo
Miguel A Ruiz-Cardozo
SSSom Singh
Som Singh
GTGabriel Trevino
Gabriel Trevino
MKMichael R. Kann
Michael R. Kann
CMCamilo A. Molina
Camilo A. Molina
Study Design: Systematic Review. Objectives: To evaluate which cervical deformity correction technique between anterior cervical discectomy and fusion (ACDF) and anterior cervical corpectomy and fusion (ACCF) produces better clinical, radiographic, and operative outcomes. Methods: We conducted a meta-analysis comparing studies involving ACDF and ACCF. Adult patients with either original or previously treated cervical spine deformities were included. Two independent reviewers categorized extracted data into clinical, radiographic, and operative outcomes, including complications. Clinical assessments included patient-reported outcomes; radiographic evaluations examined C2-C7 Cobb angle, T1 slope, T1-CL, C2-7 SVA, and graft stability. Surgical measures included surgery duration, blood loss, hospital stay, and complications. Results: 26 studies (25727 patients) met inclusion criteria and were extracted. Of these, 14 studies (19077 patients) with low risk of bias were included in meta-analysis. ACDF and ACCF similarly improve clinical outcomes in terms of JOA and NDI, but ACDF is significantly better at achieving lower VAS neck scores. ACDF is also more advantageous for improving cervical lordosis and minimizing the incidence of graft complications. While there is no significant difference between approaches for most surgical complications, ACDF is favorable for reducing operative time, intraoperative blood loss, and length of hospital stay. Conclusions: While both techniques benefit cervical deformity patients, when both techniques are feasible, ACDF may be superior with respect to VAS neck scores, cervical lordosis, graft complications and certain perioperative outcomes. Further studies are recommended to address outcome variability and refine surgical approach selection.

18 November 2024 in Medical Science Educator
Verified
Journal Article
Closed access
PDF file
MKMichael R. Kann
Michael R. Kann
DCDavid Chen
David Chen
GHGrace W. Huang
Grace W. Huang
SPSangami Pugazenthi
Sangami Pugazenthi
NZNichole G. Zehnder
Nichole G. Zehnder