Martin Chicoine

Martin Chicoine

Auto-generated profile, based on publicly available information

Martin Chicoine

Département de Physique, Université de Montréal, Montréal, Quebec H3C 3J7, Canada

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Science Advances
Verified
Journal Article
Open access
LYLe Yang
Le Yang
Gabriele VajenteGabriele Vajente
Gabriele Vajente
MFMariana Fazio
Mariana Fazio
AAAlena Ananyeva
Alena Ananyeva
GBGariLynn Billingsley
GariLynn Billingsley
CMCarmen S. Menoni
Carmen S. Menoni
The medium-range order in GeO 2 thin-film glasses is higher with elevated deposition temperature.

23 March 2022 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
MGMassimo Granata
Massimo Granata
AAAlex Amato
Alex Amato
MBM. Bischi
M. Bischi
MBM. Bazzan
M. Bazzan
GCG. Cagnoli
G. Cagnoli
FSF. Schiettekatte
F. Schiettekatte
Brownian thermal noise associated with highly reflective coatings is a fundamental limit for several precision experiments, including gravitational-wave detectors. Research is currently ongoing to find coatings with low thermal noise that also fulfill strict optical requirements such as low absorption and scatter. We report on the optical and mechanical properties of ion-beam-sputtered magnesium fluoride thin films and we discuss the application of such coatings in current and future gravitational-wave detectors.

9 May 2024 in Classical and Quantum Gravity
Verified
Journal Article
Open access
PDF file
ÉLÉmile Lalande
Émile Lalande
ADAaron Davenport
Aaron Davenport
LMLory Marchand
Lory Marchand
AMAshot Markosyan
Ashot Markosyan
DMDaniel Martinez
Daniel Martinez
Gabriele VajenteGabriele Vajente
Gabriele Vajente
Blistering is a phenomenon sometimes observed in sputtered-deposited thin films but seldom investigated in detail. Here, we consider the case of titania-doped germania (TGO)/silica multilayers deposited by ion beam sputtering. TGO is a candidate as high refractive index material in the Bragg mirrors for the next iteration of gravitational waves detectors. It needs to be annealed at 600 ∘C for 100 h in order to reach the desired relaxation state. However under some growth conditions, in 52-layer TGO/silica stacks, blistering occurs upon annealing at a temperature near 500 ∘C, which corresponds to the temperature where Ar desorbs from TGO. In order to better understand the blistering phenomenon, we measure the Ar transport in single layers of TGO and silica. In the case of < 1 µm-thick TGO layers, the Ar desorption is mainly limited by detrapping. The transport model also correctly predicts the evolution of the total amount of Ar in a 8.5 µm stack of TGO and silica layers annealed at 450 ∘C, but in that case, the process is mainly limited by diffusion. Since Ar diffusion is an order of magnitude slower in TGO compared to silica, we observe a correspondingly strong accumulation of Ar in TGO. The Ar transport model is used to explain some regimes of the blisters growth, and we find indications that Ar accumulation is a driver for their growth in general, but the blisters nucleation remains a complex phenomenon influenced by several other factors including stress, substrate roughness, and impurities.

1 May 2008 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
NDNicholas Desrosiers
Nicholas Desrosiers
AGAlexandre Giguère
Alexandre Giguère
BTBernard Terreault
Bernard Terreault
MCMartin Chicoine
Martin Chicoine
FSFrançois Schiettekatte
François Schiettekatte

1 August 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
PVPierre Vinchon
Pierre Vinchon
SAS. Asadollahi
S. Asadollahi
CCC. Coté
C. Coté
SMS. Marcet
S. Marcet
SAS. Atallah
S. Atallah
LSLuc Stafford
Luc Stafford
During deposition, modification, and etching of thin films and nanomaterials in reactive plasmas, many active species can interact with the sample simultaneously. This includes reactive neutrals formed by fragmentation of the feed gas, positive ions, and electrons generated by electron-impact ionization of the feed gas and fragments, excited states (in particular, long-lived metastable species), and photons produced by spontaneous de-excitation of excited atoms and molecules. Notably, some of these species can be transiently present during the different phases of plasma processing, such as etching of thin layer deposition. To monitor plasma–surface interactions during materials processing, a new system combining beams of neutral atoms, positive ions, UV photons, and a magnetron plasma source has been developed. This system is equipped with a unique ensemble of in-plasma surface characterization tools, including (1) a Rutherford Backscattering Spectrometer (RBS), (2) an Elastic Recoil Detector (ERD), and (3) a Raman spectroscopy system. RBS and ERD analyses are carried out using a differentially pumped 1.7 MV ion beam line Tandetron accelerator generating a beam at grazing incidence. The ERD system is equipped with an absorber and is specifically used to detect H initially bonded to the surface; higher resolution of surface H is also available through nuclear reaction analysis. In parallel, an optical port facing the substrate is used to perform Raman spectroscopy analysis of the samples during plasma processing. This system enables fast monitoring of a few Raman peaks over nine points scattered on a 1.6 × 1.6 mm2 surface without interference from the inherent light emitted by the plasma. Coupled to the various plasma and beam sources, the unique set of in-plasma surface characterization tools detailed in this study can provide unique time-resolved information on the modification induced by plasma. By using the ion beam analysis capability, the atomic concentrations of various elements in the near-surface (e.g., stoichiometry and impurity content) can be monitored in real-time during plasma deposition or etching. On the other hand, the evolution of Raman peaks as a function of plasma processing time can contribute to a better understanding of the role of low-energy ions in defect generation in irradiation-sensitive materials, such as monolayer graphene.

17 May 2024 in Classical and Quantum Gravity
Verified
Journal Article
Open access
DDD Diksha
D Diksha
AAAlex Amato
Alex Amato
VSV Spagnuolo
V Spagnuolo
GMG I McGhee
G I McGhee
MCM Chicoine
M Chicoine
JSJessica Steinlechnr
Jessica Steinlechnr
One of the main noise sources in current gravitational-wave detectors is the thermal noise of the high-reflectivity coatings on the main interferometer optics. Coating thermal noise is dominated by the mechanical loss of the high-refractive index material within the coating stacks, Ta 2 O 5 mixed with TiO 2 . For upgrades to room-temperature detectors, a mixture of GeO 2 and TiO 2 is an interesting alternative candidate coating material. While the rather low refractive index of GeO2 increases with increasing TiO 2 content, a higher TiO 2 content results in a lower threshold temperature before heat treatment leads to crystallisation, and potentially to a degradation of optical properties. For future cryogenic detectors, on the other hand, a higher TiO 2 content is beneficial as the TiO2 suppresses the low-temperature mechanical loss peak of GeO2. In this paper, we present the optical properties of coatings—produced by plasma-assisted ion-beam evaporation—with high TiO2 content at 1550 nm, a laser wavelength considered for cryogenic gravitational-wave detectors, as a function of heat-treatment temperature. For comparison, the absorption of pure GeO2 was also measured. Furthermore, results at the currently-used wavelength of 1064 nm are presented.