Marko Tealane

Marko Tealane

Auto-generated profile, based on publicly available information

Marko Tealane

Department of Electrical Power Engineering and Mechatronics, Tallinn University of Technology, Tallinn, Estonia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2022 in IEEE Access
Verified
Journal Article
Open access
MTMarko Tealane
Marko Tealane
JKJako Kilter
Jako Kilter
MPMarjan Popov
Marjan Popov
OBOleg Bagleybter
Oleg Bagleybter
DKDanny Klaar
Danny Klaar
This paper presents a robust and adaptive out-of-step (OOS) protection algorithm, using wide-area information, that can be applied on tie-lines in observable power systems. The developed algorithm is based upon real-time computation of the system impedance and makes use of the well-known power-angle characteristic. In this way, a setting-less OOS concept in real-time environment is developed, which is applicable for tie-lines in an arbitrary power system. Furthermore, the developed protection algorithm is installed on hardware and is verified by numerous tests. The performance of the new hardware implementation is compared to the traditional impedance-based OOS protection methods. The results confirm that the proposed algorithm detects OOS conditions faster and more reliably than the traditional impedance-based solutions.

25 July 2022 in IEEE Access
Verified
Journal Article
Open access
MTMarko Tealane
Marko Tealane
JKJako Kilter
Jako Kilter
OBOleg Bagleybter
Oleg Bagleybter
BHBirkir Heimisson
Birkir Heimisson
MPMarjan Popov
Marjan Popov
This paper presents an out-of-step protection algorithm based on angle derivatives, which makes use of wide-area measurements and can be applied on arbitrary tie-lines in electrical power systems. The developed algorithm uses PMU measurements that are taken at both ends of a transmission line. Based on the changes of the electrical quantities in the power system, the algorithm detects unstable system conditions. Thus, the developed solution is settingless and can be easily applied where an out-of-step condition is expected. The concept is deployed by using an industrial controller and tested by conducting numerous hardware-in-the-loop simulations. Additionally, recorded data from actual out-of-step events in the Icelandic power system are used to validate the developed algorithm. The performance of the implemented method is compared against the traditional impedance-based out-of-step protection methods. The results confirm that the proposed algorithm detects out-of-step conditions more reliably and faster than the traditional impedance-based solutions.

28 September 2020
Verified
Conference Paper
Closed access
IKIvar Kiitam
Ivar Kiitam
MSMart Saarna
Mart Saarna
PTPaul Taklaja
Paul Taklaja
MTMarko Tealane
Marko Tealane
IPIvo Palu
Ivo Palu
The aging of insulation materials is of great importance in determining useful lifetime of electrical equipment. Mechanical and electrical tests were conducted on aged 6 kV porcelain support insulators, which were in service for 70 years in an indoor substation. The mechanical tests included compression, tension and bending of the insulators until failure. The electrical tests included application of standard lightning impulse voltages and determining the 50% probability flashover voltage for both positive and negative polarities and determining 50 Hz AC flashover voltage. In electrical tests, puncture did not occur. Across all of the tests, the insulators were found to conform to the initial parameters specified by the manufacturer. It was found that the deterioration of the porcelain insulator had not reached an excessively high level despite the substantially long service time.