Ying Guo

Ying Guo

Auto-generated profile, based on publicly available information

Ying Guo

Data61, Commonwealth Scientific and Industrial Research Organization, Marsfield, NSW, Australia

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2023 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
YGYing Guo
Ying Guo
ZYZhihong Yu
Zhihong Yu
ZHZhenjie Hou
Zhenjie Hou
WZWenGuang Zhang
WenGuang Zhang
GQGuimei Qi
Guimei Qi

20 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
LYLin Ye
Lin Ye
YGYing Guo
Ying Guo
Steven SuSteven Su
Steven Su
This paper presents an innovative in-field calibration method for portable triaxial magnetometers (TMs). For in-field calibration of portable sensors, it is difficult to provide accurately measured inputs to each sensitivity axis due to the unavailability of high precision turntables. Because of this limitation, most existing in-field calibration methods often require nonlinear optimization to identify model parameters. According to the fact that the angle between the local gravity and magnetic field is invariant, a new in-field calibration approach called Inclination Based Calibration (I-Calibration) was proposed. The I-Calibration could reliably estimate model parameters of the magnetometers by simply using a linear Least Square estimator. A 12-observation Icosahedron experimental scheme was performed for a micro Inertial Measurement Unit, which contains both triaxial accelerometers (TAs) and triaxial magnetometers. The effectiveness, as well as the robustness with the misalignments of the TAs and TMs, of the proposed calibration method, was first verified by using numerical simulations. Thereafter, in real data experiments, the proposed method was compared with an existing calibration approach, named Magnitude Based Calibration (M-Calibration), which is based on the fact that the magnitude of the local magnetic field is invariant. The calibrated results together with the comparison between the two methods demonstrated the effectiveness of the proposed method.

1 October 2008
Verified
Conference Paper
Closed access
HFHaining Fan
Haining Fan
YGYing Guo
Ying Guo
XFXin Feng
Xin Feng
A new method is presented for blind parameter estimation of frequency hopping signals. According to the inner structure of frequency hopping signals, the three-parameter frequency-time atom is obtained from the unit windowed sine function by successive applications of scaling, time-shift and frequency-shift operators. On the base of these, a new matching pursuit based parameter estimation method of frequency hopping signal is developed. Using this method, the parameter of frequency hopping signals i.e. as hop duration, hop timing and hopping frequencies can be estimated without any priori knowledge. Simulation results demonstrate that the method is effective and efficient.

19 September 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
YGYing Guo
Ying Guo
LYLin Ye
Lin Ye
Steven SuSteven Su
Steven Su
In this article, we propose a procedure for the investigation of the feasibility and effectiveness of recently developed in-field magnetometer calibration methods. Extensive numerical analyses under different noise levels are conducted to identify the proper measurement conditions of each method. The variance analysis is also presented to study the observability of model parameters based on the information matrix under different inclination angles. In accordance with the analysis, several important conclusions are drawn including the condition to ensure the validity of the parameter estimation and the approach to improve the performance of the calibration results. Numerical simulation and experimental validation support our analytical findings. Accordingly, this study provides an in-depth exploration of the limitations of typical in-field magnetometer calibration methods.

14 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
YGYing Guo
Ying Guo
LYLin Ye
Lin Ye
THTao Han
Tao Han
Steven SuSteven Su
Steven Su
In this paper, a linear triaxial magnetometer calibration model with six observations is proposed for wearable Inertial Measurement Unit sensors. First, the information matrix of the six-parameter calibration model is derived under the proposed six-observation scheme, and its G-optimality is proven. Thereafter, a series of simulation studies were conducted to demonstrate the effectiveness and robustness of the six-observation scheme. Finally, the designed six-observation scheme is experimentally verified by the commercial Inertial Measurement Unit devices. The simulation and experimental results both demonstrate the efficiency and accuracy of the proposed optimal six-observation scheme. This scheme simplifies the calibration procedure and reduces the calculation workload, further providing guidance for the daily use of wearable sensor calibration.

18 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
YGYing Guo
Ying Guo
LYLin Ye
Lin Ye
Steven SuSteven Su
Steven Su
This study presents an in-depth analysis of the Optimal Experimental Design for in-field calibration of tri-axial magnetometers, with a particular focus on the 9-parameter inclination-based calibration model and its implementation through 12-observation schemes. Initially, the paper examines various experimental schemes applicable to different global locations, and integrates theoretical analysis with simulation and experimental results. Then, the information matrix for the proposed 9-parameter model under the outlined 12-observation scheme is derived. Based on that the G-optimality of the proposed scheme is proved. Subsequent simulation studies rigorously evaluate the scheme’s resilience to variations in the bias angles between actual placement and ideal position, as the bias angles change from 0° to 90°, the relative efficiency decreases from 1 to 3.7586 × 10 -33 . Finally, the practical application situation of the 9-parameter calibration model and 12-observation scheme is experimentally verified by using commercial Inertial Measurement Unit devices in diverse locations. This research not only proposes a suite of numerical solutions for ideal conditions but also offers a pragmatic guide for assessing actual device placement in field applications.