Hairong Yu

Dr. Hairong Yu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
LHLiu He
Liu He
ZDZhao-Jie Dong
Zhao-Jie Dong
XDXin Du
Xin Du
CJChao Jiang
Chao Jiang
Ning ChenNing Chen
Ning Chen
CMChangsheng Ma
Changsheng Ma
Aims This study sought to compare healthcare quality and 30 day, 90 day, and 1 year mortality rates among patients admitted to secondary and tertiary hospitals for heart failure (HF) in Beijing. Methods and results This study retrospectively enrolled patients hospitalized with a primary discharge diagnosis of HF during January 2014 to December 2015, from five tertiary and four secondary hospitals, in Beijing, China. Mortality data were extracted from Beijing Death Surveillance Database. HF healthcare quality indices were used to evaluate in‐hospital care. Associations between hospital level and mortality rates were assessed using generalized linear mixed models, adjusting for patients' baseline characteristics and intra‐hospital correlation. Data from 1413 patients (median [interquartile range] age = 74 [65–80] years, 52.7% female) from secondary hospitals and 1250 patients (median [interquartile range] age = 72 [61–79] years, 43.3% female) from tertiary hospitals were collected. Rates of left ventricular ejection fraction assessment (73.2% vs. 90.1%) and combined use of β‐blockers and angiotensin‐converting enzyme inhibitors/angiotensin II receptor blockers (30.1% vs. 49.3%) were lower in secondary hospitals than those in tertiary hospitals, respectively. Patients admitted to secondary hospitals had a higher 90 day mortality [10.8% vs. 5.0%; adjusted odds ratio (OR): 2.06; 95% confidence interval (CI): 1.10–3.84, P = 0.024 and a higher 1 year mortality rate [21.0% vs. 12.1%; adjusted OR: 1.64; 95% CI: 1.02–2.62, P = 0.039], but 30 day mortality rates were not significantly different (5.5% vs. 3.0%; adjusted OR: 1.49; 95% CI: 0.63–3.52, P = 0.368). Conclusions Worse quality of care for patients with HF in secondary hospitals was associated with higher 90 day and 1 year mortality rates. Improving care quality in secondary hospitals is crucial to improve prognosis of patients they served.

20 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
LYLin Ye
Lin Ye
YGYing Guo
Ying Guo
Steven SuSteven Su
Steven Su
This paper presents an innovative in-field calibration method for portable triaxial magnetometers (TMs). For in-field calibration of portable sensors, it is difficult to provide accurately measured inputs to each sensitivity axis due to the unavailability of high precision turntables. Because of this limitation, most existing in-field calibration methods often require nonlinear optimization to identify model parameters. According to the fact that the angle between the local gravity and magnetic field is invariant, a new in-field calibration approach called Inclination Based Calibration (I-Calibration) was proposed. The I-Calibration could reliably estimate model parameters of the magnetometers by simply using a linear Least Square estimator. A 12-observation Icosahedron experimental scheme was performed for a micro Inertial Measurement Unit, which contains both triaxial accelerometers (TAs) and triaxial magnetometers. The effectiveness, as well as the robustness with the misalignments of the TAs and TMs, of the proposed calibration method, was first verified by using numerical simulations. Thereafter, in real data experiments, the proposed method was compared with an existing calibration approach, named Magnitude Based Calibration (M-Calibration), which is based on the fact that the magnitude of the local magnetic field is invariant. The calibrated results together with the comparison between the two methods demonstrated the effectiveness of the proposed method.

20 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
LYLin Ye
Lin Ye
YGYing Guo
Ying Guo
Steven SuSteven Su
Steven Su
In this paper, an innovative algorithm for Tri-Axial Magnetometers calibration based on the magnetic inclination is proposed. The proposed “Inclination based Calibration method” uses the fact that the angle between the local gravity and magnetic field is invariant hence overcoming the limitations of most existing in-field calibration methods which require nonlinear optimization. This calibration algorithm is formulated as the solution to a linear least square problem. A commonly used 9- parameter model and its associated 12-observation Icosahedron experimental scheme were developed to evaluate its applicability to calibrated Tri-Axial Magnetometers based on measured acceleration and magnetic data. The results show that the algorithm can provide effective calibration results for the magnetic field in both simulation and experiments. In addition, the influence of accelerometers data applied in this algorithm is investigated by simulation and experiment to demonstrate the importance of accelerometers data accuracy. The acceleration value after effective calibration is demonstrated to make an improvement in the estimation results.

19 September 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
YGYing Guo
Ying Guo
LYLin Ye
Lin Ye
Steven SuSteven Su
Steven Su
In this article, we propose a procedure for the investigation of the feasibility and effectiveness of recently developed in-field magnetometer calibration methods. Extensive numerical analyses under different noise levels are conducted to identify the proper measurement conditions of each method. The variance analysis is also presented to study the observability of model parameters based on the information matrix under different inclination angles. In accordance with the analysis, several important conclusions are drawn including the condition to ensure the validity of the parameter estimation and the approach to improve the performance of the calibration results. Numerical simulation and experimental validation support our analytical findings. Accordingly, this study provides an in-depth exploration of the limitations of typical in-field magnetometer calibration methods.

14 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHairong Yu
Hairong Yu
YGYing Guo
Ying Guo
LYLin Ye
Lin Ye
THTao Han
Tao Han
Steven SuSteven Su
Steven Su
In this paper, a linear triaxial magnetometer calibration model with six observations is proposed for wearable Inertial Measurement Unit sensors. First, the information matrix of the six-parameter calibration model is derived under the proposed six-observation scheme, and its G-optimality is proven. Thereafter, a series of simulation studies were conducted to demonstrate the effectiveness and robustness of the six-observation scheme. Finally, the designed six-observation scheme is experimentally verified by the commercial Inertial Measurement Unit devices. The simulation and experimental results both demonstrate the efficiency and accuracy of the proposed optimal six-observation scheme. This scheme simplifies the calibration procedure and reduces the calculation workload, further providing guidance for the daily use of wearable sensor calibration.

4 December 2020 in IEEE Access
Verified
Journal Article
Open access
HYHairong Yu
Hairong Yu
YZYi Zhang
Yi Zhang
LYLin Ye
Lin Ye
HAHamzah M. Alqudah
Hamzah M. Alqudah
KGKairui Guo
Kairui Guo
Steven SuSteven Su
Steven Su
Intelligent regulation for human exercise behaviors becomes significantly necessary for exercise medicine after the COVID-19 epidemic. The key issue of exercise regulation and its potential development for intelligent exercise is to describe human exercise physiological behaviors in a more accurate and sufficient manner. Here, a non-parametric modeling method with kernel-based regularization is presented to estimate cardiorespiratory biomarkers (i.e., oxygen uptake (V̇O2 ) and carbon dioxide output (V̇CO2 ) by merely non-invasively monitoring the indicator of exercise intensity (e.g., walking speed). Using the kernel-based non-parametric modeling, we show that V̇O2 and V̇CO2 behaviors in response to continuous and diversified exercise intensity stimulations can be quantitatively described. Furthermore, the dataset from the stairs experiment with a proper protocol is applied in the kernel parameter selection, and this selection approach is compared with the numerical simulation approach. The comparison results illustrate an improvement of 4.18% for oxygen uptake and 7.63% for carbon dioxide output in a half period, and 11.00% for oxygen uptake and 12.60% for carbon dioxide output in one period when using the kernel parameter selected from the stairs exercise. Moreover, the advantages of using the non-parametric model, the necessity of sufficient stimulation for identification and the importance of the kernel regularization term are also addressed in this paper. This method provides fundamental work for the practice of intelligent exercise.