Mustafa Özkaya

Mustafa Özkaya

Auto-generated profile, based on publicly available information

Mustafa Özkaya

Department of Mechanical Engineering, KTO Karatay University, Konya, Türkiye

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2016 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
FTFaik Türkmen
Faik Türkmen
BKBurkay K. Kaçıra
Burkay K. Kaçıra
MÖMustafa Özkaya
Mustafa Özkaya
ÖEÖmer F. Erkoçak
Ömer F. Erkoçak
MAMehmet A. Acar
Mehmet A. Acar
TDTeyfik Demir
Teyfik Demir

1 January 2015 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
EÇEngin Çetin
Engin Çetin
MÖMustafa Özkaya
Mustafa Özkaya
ÜGÜmit Özgür Güler
Ümit Özgür Güler
EAEmre Acaroğlu
Emre Acaroğlu
TDTeyfik Demir
Teyfik Demir
Introduction.Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated.Materials and Method.30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods.Results.In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01). Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005).Conclusion.Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

18 April 2022 in Journal of Animal Physiology and Animal Nutrition
Verified
Journal Article
Closed access
SYSakine Yalçın
Sakine Yalçın
MRMuhammad Shazaib Ramay
Muhammad Shazaib Ramay
OGOğuz Berk Güntürkün
Oğuz Berk Güntürkün
SYSıddika Songül Yalçın
Sıddika Songül Yalçın
OAOZAN AHLAT
OZAN AHLAT
MÖMustafa Özkaya
Mustafa Özkaya

23 February 2018 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
HÖHakan Özalp
Hakan Özalp
MÖMustafa Özkaya
Mustafa Özkaya
OYOnur Yaman
Onur Yaman
TDTeyfik Demir
Teyfik Demir
Transdiscal screw fixation is generally performed in the treatment of high-grade L5–S1 spondylolisthesis. The main thought of the study is that the biomechanical performances of the transdiscal pedicle screw fixation can be identical to standard posterior pedicle screw fixations with or without transforaminal lumbar interbody fusion cage insertion. Lumbosacral portions and pelvises of 45 healthy lambs’ vertebrae were dissected. Animal cadavers were randomly and equally divided into three groups for instrumentation. Three fixation systems, L5–S1 posterior pedicle screw fixation, L5–S1 posterior pedicle screw fixation with transforaminal lumbar interbody fusion cage insertion, and L5–S1 transdiscal pedicle screw fixation, were generated. Axial compression, flexion, and torsion tests were conducted on test samples of each system. In axial compression, L5–S1 transdiscal fixation was less stiff than L5–S1 posterior pedicle screw fixation with transforaminal lumbar interbody fusion cage insertion. There were no significant differences between groups in flexion. Furthermore, L5–S1 posterior fixation was stiffest under torsional loads. When axial compression and flexion loads are taken into consideration, transdiscal fixation can be alternatively used instead of posterior pedicle screw fixation in the treatment of L5–S1 spondylolisthesis because it satisfies enough stability. However, in torsion, posterior fixation is shown as a better option due to its higher stiffness.

25 October 2015 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
DKDursun O Karakoyun
Dursun O Karakoyun
MÖMustafa Özkaya
Mustafa Özkaya
VOVolkan C Okutan
Volkan C Okutan
ADAli Dalgıç
Ali Dalgıç
DBDeniz Belen
Deniz Belen
TDTeyfik Demir
Teyfik Demir
Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal fusion. In this study, four different unilateral pedicle screw fixation systems were evaluated to determine which one best approximated an intact spine with respect to biomechanics and kinematics. The four groups included an intact group, a unilateral facetectomy group with no fixation, a unilateral semi-rigid pedicle screw fixation group with a poly-ether-ether-ketone rod, and a unilateral dynamic pedicle screw fixation group. The bone mineral densities of all specimens were measured and specimens were matched with groups randomly. Flexion, lateral bending, and axial rotation tests were performed to compare the groups. For the flexion, lateral bending, and axial rotation tests, the best biomechanical outcomes were in the control group. The unilateral facetectomy group had the poorest performance and was not stable enough, compared with the control group. The dynamic and semi-rigid groups showed performance closer to that of the control group. The biomechanical responses of these two groups were also in good agreement, showing no significant statistical differences. Based on these test results, it is concluded that the unilateral dynamic and semi-rigid pedicle screw fixations can be used to provide stability to the vertebrae.